Electric discharge machining – A potential choice for surface modification of metallic implants for orthopedic applications: A review
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Among the various metallic implant materials, titanium (Ti) alloy is the best choice for the long-term hard body tissue replacements such as hip and knee joints. It has excellent mechanical, superior biological and strong anticorrosion properties. Besides the appropriate implant material, its surface topology also plays a very important role in the success of any surgery. The surface topology is supposed to be the key factor for the promotion of osseointegration. This research article focuses its attention mainly on surface modification of Ti-based alloys by electric discharge machining process. Electric discharge machining is one of the most popular nonconventional manufacturing methods. Besides machining and surface modification of implants, it finds applications in almost all areas of manufacturing industries. This article reviews the various research work done on surface modification of Ti alloy by electric discharge machining and attempts to bring out the current scenario along with future directions. The area under focus for this research review is orthopedics applications. Furthermore, a new promising advancement in the area of enhancement of electric discharge machining performance for surface modification, particularly with regard to biocompatibility and surface quality of biomaterials, has also been introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416 · cited 6×
“It is important that an implant material mimics as closely as possible the mechanical properties of the natural bone, especially elastic modulus equivalent to that of bone (5–30GPa).(2) Other properties such as hardness, tensile strength and elongation should also be kept in mind while selecting the material for impla…”
BackgroundInfluentialTitanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510 · cited 2×
“Mechanical properties of metallic implant materials.(4)”
BackgroundSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487 · cited 3×
“Surface modification techniques for titanium alloy as biomedical implant.(8)”
BackgroundMethodInfluentialOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · cited 1×
“The ability of an implant material to withstand an appropriate host response in a specific situation measures the biocompatibility of a material.(6)”
BackgroundState of the art electrical discharge machining (EDM)
Ho, K. H., & Newman, S. T. (2003) · International Journal of Machine Tools and Manufacture · doi:10.1016/s0890-6955(03)00162-7 · Cited by 1,729 · cited 1×
“So, vibration and chatters are almost 0, and thus, any conductive and complex shapes within very close tolerances can be machined or manufactured or modified easily.(85) Because of all these advantages, it finds applications in mold, die, automotive, aerospace and medical industries.”
BackgroundDevelopment of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623 · cited 1×
“So, the researcher developed biocompatible V and Al-free b-phase Ti alloy such as Ti-Nb,(12) Ti-Zr,(12) Ti-Nb-Zr,(13) Ti-Nb-Ta-Mo,(13) Ti-Nb-Ta-Sn(13) and Ti-NbTa-Zr (TNTZ) alloys to overcome the toxicity of titanium–vanadium-based alloy.(14) Very recently developed b-type Ti alloys have lower elastic modulus of 55GPa…”
MethodEnhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048 · cited 2×
“To meet the joint replacement challenges, the development of various implant material has been witnessed, and the need of biomaterials is increasing rapidly.(1) The biomaterials are categorized as metallic, ceramics and polymers.”
BackgroundSpecific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<475::aid-jbm23>3.0.co;2-9 · Cited by 989
High surface energy enhances cell response to titanium substrate microstructure
Zhao, G., Schwartz, Z., Wieland, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Boyan, B. D. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30320 · Cited by 922
Advancing EDM through Fundamental Insight into the Process
Kunieda, M., Lauwers, B., Rajurkar, K. P., & Schumacher, B. M. (2005) · CIRP Annals · doi:10.1016/s0007-8506(07)60020-1 · Cited by 921 · cited 3×
“Such a discharge location may be the spot where the gap is small or contaminated with eroded debris particles which may weaken the breakdown strength of dielectric liquid.(110) Accordingly, the pulse interval (pulse-off) time between pulse discharges must be sufficiently long, so that the plasma generated by the previ…”
BackgroundInfluentialMatsuno, H. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00275-1 · Cited by 828
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827 · cited 3×
“The size of porosity has a favorable impact on cell adhesion, proliferation and new bone formation.(7) Controlled surface roughness and surface chemistry play a critical role in the formation of new bone ingrowths around implant.”
BackgroundInfluentialRupp, F., Scheideler, L., Olshanska, N., de Wild, M., Wieland, M., & Geis‐Gerstorfer, J. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30518 · Cited by 651
Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti–29Nb–13Ta–4.6Zr
Niinomi, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00069-3 · Cited by 549
Minagar, S., Berndt, C. C., Wang, J., Ivanova, E. P., & Wen, C. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.005 · Cited by 475
Electrical discharge machining of titanium alloy (Ti–6Al–4V)
Hasçalık, A., & Çaydaş, U. (2007) · Applied Surface Science · doi:10.1016/j.apsusc.2007.05.031 · Cited by 468
Underlying mechanisms at the bone–biomaterial interface.
Schwartz, Z., & Boyan, B. D. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240560310 · Cited by 397 · cited 1×
“The past research work shows that surface properties play a critical and a very important role in new bone formation(53) and further growth of tissues.(54) Surface properties such as surface roughness,(55) surface topography,(56) surface porosity,(57) surface chemistry(58,59) and surface energy(60,61) have found signi…”
BackgroundOkazaki, Y., Rao, S., Ito, Y., & Tateishi, T. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00235-4 · Cited by 382 · cited 2×
“So, the researcher developed biocompatible V and Al-free b-phase Ti alloy such as Ti-Nb,12 Ti-Zr,12 Ti-Nb-Zr,13 Ti-Nb-Ta-Mo,13 Ti-Nb-Ta-Sn13 and Ti-NbTa-Zr (TNTZ) alloys to overcome the toxicity of titanium–vanadium-based alloy.14 Very recently developed b-type Ti alloys have lower elastic modulus of 55GPa (near to bo…”
BackgroundThe Role of Implant Surface Characteristics in the Healing of Bone
Kieswetter, K., Schwartz, Z., Dean, D. D., & Boyan, B. D. (1996) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411960070040301 · Cited by 338
Liu, X., Lim, J. Y., Donahue, H. J., Dhurjati, R., Mastro, A. M., & Vogler, E. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.016 · Cited by 321
Biomedical production of implants by additive electro-chemical and physical processes
Bartolo, P., Kruth, J.-P., Silva, J., Levy, G., Malshe, A., Rajurkar, K., Mitsuishi, M., Ciurana, J., & Leu, M. (2012) · CIRP Annals · doi:10.1016/j.cirp.2012.05.005 · Cited by 321 · cited 1×
“The selection of the right biomaterials for a specific biomedical application depends upon their comprehensive properties such as biodegradability, biocompatibility, mechanical properties, nontoxicity, corrosion or wear resistance and mainly on surface chemistry and morphology.(5) A biomaterial must satisfy the follow…”
BackgroundNiinomi, M. (2008) · Journal of Artificial Organs · doi:10.1007/s10047-008-0422-7 · Cited by 295 · cited 2×
“bone.(10) Ti and its alloys gained more attention in recent scenario, due to their superior biocompatibility and excellent mechanical properties especially low Young’s modulus, high fatigue performance, high corrosion resistance and low density as compared with other metallic biomaterials.”
BackgroundCells React to Nanoscale Order and Symmetry in Their Surroundings
Curtis, A. S. G., Gadegaard, N., Dalby, M. J., Riehle, M. O., Wilkinson, C. D. W., & Aitchison, G. (2004) · IEEE Transactions on Nanobioscience · doi:10.1109/tnb.2004.824276 · Cited by 288 · cited 1×
“The cell reacts with nano-scale surface and their surrounding.(71) The growth behavior of rat calvaria bone cell on the surface with nanometric features was found.”
BackgroundOsteoblast-Mediated Mineral Deposition in Culture is Dependent on Surface Microtopography
Boyan, B. D., Bonewald, L. F., Paschalis, E. P., Lohmann, C. H., Rosser, J., Cochran, D. L., Dean, D. D., Schwartz, Z., & Boskey, A. L. (2002) · Calcified Tissue International · doi:10.1007/s00223-001-1114-y · Cited by 256 · cited 1×
“These different scales of surface roughness have their own impact on bone ingrowths.(56) Generally, microscale rough surface is preferred because large surface indentations provide a better interaction of implant to the surrounding bone tissues.”
BackgroundCorrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation
Antunes, R. A., & de Oliveira, M. C. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.012 · Cited by 250 · cited 1×
“There are well-documented reports on the failure of cobalt-based implants by corrosion fatigue.(21) The crack growth was predicted under air or corrosive environment accelerated by fatigue performance.”
BackgroundOsteoblast‐like cells are sensitive to submicron‐scale surface structure
Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., & Boyan, B. D. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01195.x · Cited by 248 · cited 1×
“However, it was found that the surface of micro-scale roughness indentations is an arguable characteristic promoting cells and tissues around implant surface.(69) Over the last several decades, few researchers have drawn their attention toward the surface with nano-scale roughness irregularity.”
BackgroundLiu, X.-B., Meng, X.-J., Liu, H.-Q., Shi, G.-L., Wu, S.-H., Sun, C.-F., Wang, M.-D., & Qi, L.-H. (2014) · Materials & Design · doi:10.1016/j.matdes.2013.09.038 · Cited by 238
Rodrigues, D. C., Urban, R. M., Jacobs, J. J., & Gilbert, J. L. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31171 · Cited by 224 · cited 1×
“In another study, the hydrogen embrittlement was found to be the main cause for the fretting and corrosive corrosion.(44) Yokoyama et al.”
BackgroundLipski, A. M., Pino, C. J., Haselton, F. R., Chen, I.-W., & Shastri, V. P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.002 · Cited by 187 · cited 1×
“It was found that nano-scale surface roughness of the material surface has been considered as the most advantageous and advisable factor for the formation, adhesion, growth and differentiation of new bone cells.(70) The cell reacts with nano-scale surface and their surrounding.”
BackgroundVANDROVCOVÁ, M., & BAČÁKOVÁ, L. (2011) · Physiological Research · doi:10.33549/physiolres.932045 · Cited by 179 · cited 1×
“mm).(64,65) These different scales of surface roughness have their own impact on bone ingrowths.”
BackgroundFracture mechanisms of retrieved titanium screw thread in dental implant
Yokoyama, K., Ichikawa, T., Murakami, H., Miyamoto, Y., & Asaoka, K. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00380-5 · Cited by 169 · cited 2×
“The main cause of the failure was surface cracks during fretting fatigue.43 In another study, the hydrogen embrittlement was found to be the main cause for the fretting and corrosive corrosion.44 Yokoyama et al.45 also reported that Ti-based dental implant becomes brittle and fracture following the exposure to hydroge…”
BackgroundEffect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screws in Vitro and in Vivo
Schwartz, Z., Raz, P., Zhao, G., Barak, Y., Tauber, M., Yao, H., & Boyan, B. D. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.00499 · Cited by 163
Rosa, A. L., & Beloti, M. M. (2003) · Brazilian Dental Journal · doi:10.1590/s0103-64402003000100003 · Cited by 152 · cited 1×
“Generally, microscale rough surface is preferred because large surface indentations provide a better interaction of implant to the surrounding bone tissues.(66) This large to surface volume provides a vehicle to interface implant with largescale cells and tissues;(67) thus, macro-roughness usually promotes cell adhesi…”
BackgroundOsteogenic Cells on Bio-Inspired Materials for Bone Tissue Engineering
Vagaská, B., Bačáková, L., Filová, E., & Balík, K. (2010) · Physiological Research · doi:10.33549/physiolres.931776 · Cited by 151
Total Hip Arthroplasty Modular Neck Failure
Skendzel, J. G., Blaha, J. D., & Urquhart, A. G. (2010) · The Journal of Arthroplasty · doi:10.1016/j.arth.2010.03.011 · Cited by 139
Harcuba, P., Bačáková, L., Stráský, J., Bačáková, M., Novotná, K., & Janeček, M. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.07.001 · Cited by 124 · cited 4×
“A possible application of EDM to fabricate rough biocompatible surface for orthopedic applications was reported by Harcuba et al.122 They reported that carbon-enriched highly macro-roughness has a favorable and better surface for adhesion and proliferation of human osteoblast-like MG-63 cells and compared with the sam…”
BackgroundResultInfluentialJabbaripour, B., Sadeghi, M. H., Shabgard, M. R., & Faraji, H. (2012) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2012.09.016 · Cited by 114
Klocke, F., Welling, D., & Dieckmann, J. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.11.099 · Cited by 85 · cited 1×
“probability of failure, the W-EDM-treated samples offered higher fatigue limit stress than grounded samples.(131) The fatigue performance of Ti-6Al-4V alloy was studied for micro-specimens and compared with Inconel alloys.”
Increased functions of osteoblasts on nanophase metals
Ward, B. C., & Webster, T. J. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.05.032 · Cited by 77 · cited 1×
“The nano-structured surface increased the function of osteoblast or cell growth.(73) The proper and appropriate surface treatment or modification not only adds or removes material on the implant surface but also improves surface morphology and chemistry as per required by different biomedical applications.”
BackgroundHavlikova, J., Stráský, J., Vandrovcová, M., Harcuba, P., Mhaede, M., Janeček, M., & Bačáková, L. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.024 · Cited by 62 · cited 4×
“An effort of the combined effect of CM and SP with EDM has been covered to melt off the surface roughness that is achieved by EDM process.(123,124) Micro- and sub-micro-surface roughness and structure are favorable for orthopedic applications.”
BackgroundMethodInfluentialCell behaviour of rat calvaria bone cells on surfaces with random nanometric features
Riehle, M. O., Dalby, M. J., Johnstone, H., MacIntosh, A. C., & Affrossman, S. (2003) · Materials Science and Engineering C · doi:10.1016/s0928-4931(02)00282-5 · Cited by 62 · cited 1×
“The growth behavior of rat calvaria bone cell on the surface with nanometric features was found.(72) The nano-structured surface increased the function of osteoblast or cell growth.”
BackgroundNanoporous Biocompatible Layer on Ti–6Al–4V Alloys Enhanced Osteoblast-like Cell Response
Lee, W. F., Yang, T. S., Wu, Y.-C., & Peng, P. (2013) · Journal of Experimental & Clinical Medicine · doi:10.1016/j.jecm.2013.04.002 · Cited by 60 · cited 1×
“The surface of nanoscale features has a favorable impact on osteoblastic responses.(118)”
BackgroundStráský, J., Havlíková, J., Bačáková, L., Harcuba, P., Mhaede, M., & Janeček, M. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.02.053 · Cited by 43 · cited 4×
“An effort of the combined effect of CM and SP with EDM has been covered to melt off the surface roughness that is achieved by EDM process.(123,124) Micro- and sub-micro-surface roughness and structure are favorable for orthopedic applications.”
BackgroundInfluentialEffect of Electrical Discharging on Formation of Nanoporous Biocompatible Layer on Ti-6Al-4V Alloys
Yang, T., Huang, M.-S., Wang, M.-S., Lin, M., Tsai, M.-Y., & Wang, P.-Y. W. (2013) · Implant Dentistry · doi:10.1097/id.0b013e31829a170a · Cited by 43
Sivam, S. P. S. S., Raj, L. A. M., Kumar, S. S., Prabhakaran, G., Dinakaran, D., & Ilankumaran, V. (2013) · Proceedings of the Institution of Mechanical Engineers Part B Journal of Engineering Manufacture · doi:10.1177/0954405413511073 · Cited by 19
Metadata
- Authors
- Prakash, C., Kansal, H. K., Pabla, B., Puri, S., & Aggarwal, A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Publisher
- SAGE Publications
- Published
- 2015-04-10
- Volume
- 230
- Issue
- 2
- Pages
- 331-353
- ISSN
- 0954-4054 (ISSN-L)
- 2041-2975
- OpenAlex
- W1969179886
- Cited by
- 184
- References
- 47
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.