Improved Vascularization of Planar Membrane Diffusion Devices following Continuous Infusion of Vascular Endothelial Growth Factor
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Improving blood vessel formation around an immunobarrier device should improve the survival of the encapsulated tissue. In the present study we investigated the formation of new blood vessels around a planar membrane diffusion device (the Baxter Theracyte System™) undergoing a continuous infusion of vascular endothelial growth factor through the membranes and into the surrounding tissue. Each device (20 μl) had both an inner immunoisolation membrane and an outer vascularizing membrane. Human recombinant vascular endothelial growth factor-165 was infused at 100 ng/day (low dose: n = 6) and 500 ng/day (high dose: n = 7) for 10 days into devices implanted SC in Sprague-Dawley rats; noninfused devices transplanted for an identical period were used as controls (n = 5). Two days following the termination of VEGF infusion, devices were loaded with 20 μl of Lispro insulin (1 U/kg) and the kinetics of insulin release from the lumen of the device was assessed. Devices were then explanted and the number of blood vessels (capillary and noncapillary) was quantified using morphometry. High-dose vascular endothelial growth factor infusion resulted in two- to threefold more blood vessels around the device than that obtained with the noninfused devices and devices infused with low-dose vascular endothelial growth factor. This increase in the number of blood vessels was accompanied by a modest increase in insulin diffusion from the device in the high-dose vascular endothelial growth factor infusion group. We conclude that vascular endothelial growth factor can be used to improve blood vessel formation adjacent to planar membrane diffusion devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rafael, E., Wernerson, A., Arner, P., & Tibell, A. (1999) · European Surgical Research · doi:10.1159/000008700 · Cited by 26 · cited 1×
“(31) showed that insulin absorp tion from similar devices improves over a period of t ime after S C implantat ion in rats.”
Background
Cited by
Alginate-based microcapsules for immunoisolation of pancreatic islets
de Vos, P., Faas, M. M., Strand, B., & Calafiore, R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.010 · Cited by 511
Advances in islet encapsulation technologies
Desai, T., & Shea, L. D. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.232 · Cited by 427
Scharp, D. W., & Marchetti, P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.018 · Cited by 314
Considerations for successful transplantation of encapsulated pancreatic islets
de Vos, P., Hamel, A. F., & Tatarkiewicz, K. (2002) · Diabetologia · doi:10.1007/s00125-001-0729-x · Cited by 252
O'Sullivan, E. S., Vegas, A., Anderson, D. G., & Weir, G. C. (2011) · Endocrine Reviews · doi:10.1210/er.2010-0026 · Cited by 207
Self-citation
Metadata
- Authors
- Trivedi, N., Steil, G. M., Colton, C. K., Bonner-Weir, S., & Weir, G. C.
- Venue
- Cell Transplantation
- Publisher
- SAGE Publications
- Published
- 2000-01
- Volume
- 9
- Issue
- 1
- Pages
- 115-124
- ISSN
- 0963-6897 (ISSN-L)
- 1555-3892
- OpenAlex
- W2423855522
- Cited by
- 87
- References
- 1
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Vascularization of Planar Membrane Diffusion Devices following Continuous Infusion of Vascular Endothelial Growth Factor. https://app.cochat.ai/papers/10.1177/096368970000900114
- The paper
- Trivedi, N., Steil, G. M., Colton, C. K., Bonner-Weir, S., & Weir, G. C. (2000). Improved Vascularization of Planar Membrane Diffusion Devices following Continuous Infusion of Vascular Endothelial Growth Factor. Cell Transplantation. https://doi.org/10.1177/096368970000900114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.