CoChat

Extracorporeal Application of a Gel-Entrapment, Bioartificial Liver: Demonstration of Drug Metabolism and Other Biochemical Functions

Nyberg, Scott L., Shirabe, Ken, Peshwa, Madhusudan V., Sielaff, Timothy D., Crotty, Paul L., Mann, Henry J., Remmel, Rory P., Payne, William D., Hu, Wei-Shou, Cerra, Frank B. · 1993 · Cell Transplantation
Cited by 85

The DOI matches its Crossref record.

Abstract

Metabolic activity of a gel-entrapment, hollow fiber, bioartificial liver was evaluated in vitro and during extracorporeal hemoperfusion in an anhepatic rabbit model. The bioartificial liver contained either 100 million rat hepatocytes (n = 12), fibroblasts (n = 3), or no cells (n = 7) during hemoperfusion of anhepatic rabbits. Eight other anhepatic rabbits were studied without hemoperfusion as anhepatic controls, and three sham rabbits served as normal controls. Albumin production rates (mean ± SEM) were similar during in vitro (17.0 ± 2.8 μg/h) and extracorporeal (18.0 ± 4.0 μg/h) application of the hepatocyte bioartificial liver. Exogenous glucose requirements were reduced (p < 0.01) and euglycemia was prolonged (p < 0.001) in anhepatic rabbits treated with the hepatocyte bioartificial liver. The maximum rate of glucose production by the hepatocyte bioartificial liver ranged from 50-80 μg/h. Plasma concentrations of aromatic amino acids, proline, alanine, and ammonia were normalized in anhepatic rabbits during hepatocyte hemoperfusion. Gel-entrapped hepatocytes in the bioartificial liver performed sulfation and glucuronidation of 4-methylumbelliferone. P450 activity was demonstrated during both in vitro and extracorporeal application of the BAL device by the formation of 3-hydroxy-lidocaine, the major metabolite of lidocaine biotransformation by gel-entrapped rat hepatocytes. In summary, a gel-entrapment, bioartificial liver performed multiple hepatocyte-specific functions without adverse side effects during extracorporeal application in an anhepatic, small animal model. With its potential for short term support of acute liver failure, scale-up of the current bioartificial liver device is indicated for further investigations in large animal, preclinical trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/096368979300200602

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 85

Metadata

Authors
Nyberg, S. L., Shirabe, K., Peshwa, M. V., Sielaff, T. D., Crotty, P. L., Mann, H. J., Remmel, R. P., Payne, W. D., Hu, W.-S., & Cerra, F. B.
Venue
Cell Transplantation
Published
1993-11
Volume
2
Issue
6
Pages
441-452
ISSN
  • 0963-6897 (ISSN-L)
  • 1555-3892
OpenAlex
W2179080101
Cited by
85
References
0
FWCI
7.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extracorporeal Application of a Gel-Entrapment, Bioartificial Liver: Demonstration of Drug Metabolism and Other Biochemical Functions. https://app.cochat.ai/papers/10.1177/096368979300200602
The paper
Nyberg, S. L., Shirabe, K., Peshwa, M. V., Sielaff, T. D., Crotty, P. L., Mann, H. J., Remmel, R. P., Payne, W. D., Hu, W.-S., & Cerra, F. B. (1993). Extracorporeal Application of a Gel-Entrapment, Bioartificial Liver: Demonstration of Drug Metabolism and Other Biochemical Functions. Cell Transplantation. https://doi.org/10.1177/096368979300200602

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.