CoChat

A Device to Measure the Oxygen Uptake Rate of Attached Cells: Importance in Bioartificial Organ Design

Open access
Foy, Brent D., Rotem, Avi, Toner, Mehmet, Tompkins, Ronald G., Yarmush, Martin L. · 1994 · Cell Transplantation
Cited by 100

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Quantification of the dependence of cellular oxygen uptake rate (OUR) on oxygen partial pressure is useful for the design and testing of bioartificial devices which utilize cells. Thus far, this information has only been obtained from suspended cells and from cells attached to microcarriers. In this work, a device was developed to obtain the dependence of OUR on oxygen partial pressure for anchorage-dependent cells cultured in standard culture dishes. The device is placed and sealed on the top of the culture dish, and holds a Clark polarographic mini-electrode flush with the bottom surface of the device. It also houses a motor to spin a magnetic stir bar within the cell chamber to insure that the medium is well-mixed. Several characteristics of the device — such as oxygen leakage into the device chamber, electrode-lag time, and linearity of the electrode at low oxygen partial pressures-were quantified and their potential effect on the values of V m(maximal OUR) and K 0.5(oxygen partial pressure at which OUR is half-maximal) were evaluated. Comparison of V m and K 0.5 values obtained with this device with previously published values for suspended rat hepatocytes, Bacillus cereus, and E. coli indicated that the technique provides values accurate within 30% as long as the cell under study has a K 0.5 greater than approximately 1.0 mmHg. For hepatocytes cultured on 0.05 mm thickness collagen gel for 1 day (n = 4) and 3 days (n = 6), V m was found to be 0.38 ± 0.12 and 0.25 ± 0.09 nmol O 2/s/106 cells, respectively, and K 0.5 was found to be 5.6 ± 0.5 and 3.3 ± 0.6 mmHg, respectively. This technique should aid in predicting bioreactor conditions such as flow rate, cell density, distance of cell from flow, and gas phase oxygen partial pressure which can lead to oxygen limitations. In addition, further studies of the effect of factors such as extracellular matrix composition, metabolic substrate, and drugs on the dependence of OUR on oxygen partial pressure for many anchorage-dependent cell types can be pursued with this technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/096368979400300609

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 100

Metadata

Authors
Foy, B. D., Rotem, A., Toner, M., Tompkins, R. G., & Yarmush, M. L.
Venue
Cell Transplantation
Published
1994-11
Volume
3
Issue
6
Pages
515-527
ISSN
  • 0963-6897 (ISSN-L)
  • 1555-3892
OpenAlex
W147432291
Cited by
100
References
1
FWCI
1.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Device to Measure the Oxygen Uptake Rate of Attached Cells: Importance in Bioartificial Organ Design. https://app.cochat.ai/papers/10.1177/096368979400300609
The paper
Foy, B. D., Rotem, A., Toner, M., Tompkins, R. G., & Yarmush, M. L. (1994). A Device to Measure the Oxygen Uptake Rate of Attached Cells: Importance in Bioartificial Organ Design. Cell Transplantation. https://doi.org/10.1177/096368979400300609

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.