The delivery of therapeutic molecules to the brain has been limited in part due to the presence of the blood–brain barrier. One potential solution is the implantation of biodegradable polymers with sustained release of drugs. Poly (DL-lactide-co-glycolide) (PLG) is a bioerodible polymer with a long and successful history of use as a suture material. More recently, PLG has been investigated for localized and sustained delivery of molecules into both peripheral sites and the brain. Despite its well-defined safety profile for parenteral applications, little information exists concerning the safety of PLG when implanted into the brain. To further characterize the biocompatibility of PLG in the brain, we examined the gliotic response following implants of PLG into the brains of rats. As a control, each animal received an injection of the suspension medium into the contralateral hemisphere. Following implantation, PLG was well tolerated. GFAP-positive astrocytes were observed throughout the cerebral cortex and striatum on both the implanted and control sides, with the reaction being greatest within the heavily myelinated fiber tracts of the corpus callosum. Quantitative analyses revealed that this reaction occurred within 1 h postsurgery, reached its peak at 1 week following surgery, and then decreased markedly by 1 month postsurgery. A minimal gliotic reaction was still present 1 year postsurgery but was localized to the needle tract. No differences in GFAP reactivity were seen between the polymer-implanted and control sides at any time point. Histological analysis determined that the majority of the PLG disappeared between 1 and 4 weeks. A set of parallel studies in which PLG samples were retrieved from the brain at various time points corroborated these findings and determined that the majority of PLG degraded within 2 weeks following implantation. Together, these results demonstrate that PLG is well tolerated following implantation into the CNS and that the astrocytic response to PLG is largely a consequence of the mechanical trauma that occurs during surgery. The biocompatibility of PLG implanted into the CNS provides further support for its use in a wide range of new therapeutic applications for sustained and localized drug delivery to the brain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/096368979900800114

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 87

Metadata

Authors
Emerich, D. F., Tracy, M. A., Ward, K. L., Figueiredo, M., Qian, R., Henschel, C., & Bartus, R. T.
Venue
Cell Transplantation
Published
1999-01
Volume
8
Issue
1
Pages
47-58
ISSN
  • 0963-6897 (ISSN-L)
  • 1555-3892
OpenAlex
W2426854287
Cited by
87
References
1
FWCI
4.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biocompatibility of Poly (DL-Lactide-co-Glycolide) Microspheres Implanted into the Brain. https://app.cochat.ai/papers/10.1177/096368979900800114
The paper
Emerich, D. F., Tracy, M. A., Ward, K. L., Figueiredo, M., Qian, R., Henschel, C., & Bartus, R. T. (1999). Biocompatibility of Poly (DL-Lactide-co-Glycolide) Microspheres Implanted into the Brain. Cell Transplantation. https://doi.org/10.1177/096368979900800114

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.