Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 938

The DOI matches its Crossref record.

IMPROVEMENTS IN THE COATING TECHNIQUE OF RADIOAUTOGRAPHY

Open access
KOPRIWA, BEATRIX MARKUS, LEBLOND, C. P.·1962·Journal of Histochemistry & Cytochemistry

Abstract

The 1958 coating technique of Messier and Leblond for radioautography—the most recent modification of the liquid emulsion method—was investigated in the hope of eliminating artefacts and discovering the optimum conditions for reliable quantitative radioautography. From a review of the properties of the various bulk emulsions available, it is concluded that NTB2 bulk emulsion is the most suitable. The proper handling of the emulsion (transportation, storage and testing operations) is described, as well as the details of an improved coating techniqe. Comparison is made of this method with the other most widely used, the strippingfilm technique. The main features of the improved coating technique are as follows: 1. Various fixatives may be used for radioautography. Zenker and presumably other mercury-containing fixatives are unreliable, but can be used after complete removal of mercury salts. 2. Dipping the sections into celloidin prevents the infiltration of the tissue by emulsion, but is otherwise unnecessary and may be omitted for routine work. 3. Emulsion coating is done by dipping sections in a bubble-free emulsion at 40°C. 4. Drying of the coated preparations is best accomplished by keeping them vertical over moistened tissue paper at 28°C and 80% relative humidity. 5. Exposure is done in a dry atmosphere at 4°C. 6. Processing is carried out at 17-18°C, as even a slight rise in temperature increases the background fog and decreases the efficiency of the emulsion. The optimal duration of development is 2 minutes for D-72 (Dektol), 6 minutes for D-l70 (Dolmi) and 3 minutes for D-178. For fixation, best results are obtained using acid fixer with hardener (or 24% hypo) for 3 minutes. 7. Mounting is done by successive immersions in an alcohol-cedar oil mixture, a xylene-balsam mixture, and balsam. Malinol may replace balsam. The improved coating technique arising from these observations was tested for its quantitative response, measured by grain counts. The suitability of the technique for quantitative radioautography is demonstrated by the fact that the reaction intensity is proportional to exposure up to at least 80 days with hematoxylin-cosin stained sections, and 1 year with unstained sections. The background increases slowly with time, but the increase is more rapid on slides with C 14-labelled sections than on those labelled with H 3. In conclusion, the improved coating technique using the NTB2 emulsion is now quite satisfactory. The next major improvement would be for the industry to provide emulsions with a standardized sensitivity and a constant, low level of fog. Nevertheless, in its present state, it is a convenient method permitting the preparation of large numbers of high quality radioautographs and is well suited to the grain counting required for quantitative radioautography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/10.3.269

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
KOPRIWA, B. M., & LEBLOND, C. P.
Venue
Journal of Histochemistry & Cytochemistry
Published
1962-05
Volume
10
Issue
3
Pages
269-284
ISSN
  • 0022-1554 (ISSN-L)
  • 1551-5044
OpenAlex
W2016029001
Cited by
938
References
0
FWCI
36.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IMPROVEMENTS IN THE COATING TECHNIQUE OF RADIOAUTOGRAPHY. https://app.cochat.ai/papers/10.1177/10.3.269
The paper
KOPRIWA, B. M., & LEBLOND, C. P. (1962). IMPROVEMENTS IN THE COATING TECHNIQUE OF RADIOAUTOGRAPHY. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1177/10.3.269

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.