The DOI matches its Crossref record.
Tuned Lamb Wave Excitation and Detection with Piezoelectric Wafer Active Sensors for Structural Health Monitoring
Abstract
The capability of embedded piezoelectric wafer active sensors (PWAS) to excite and detect tuned Lamb waves for structural health monitoring is explored. First, a brief review of Lamb waves theory is presented. Second, the PWAS operating principles and their structural coupling through a thin adhesive layer are analyzed. Then, a model of the Lamb waves tuning mechanism with PWAS transducers is described. The model uses the space domain Fourier transform. The analysis is performed in the wavenumber space. The inverse Fourier transform is used to return into the physical space. The integrals are evaluated with the residues theorem. A general solution is obtained for a generic expression of the interface shear stress distribution. The general solution is reduced to a closed-form expression for the case of ideal bonding which admits a closed-form Fourier transform of the interfacial shear stress. It is shown that the strain wave response varies like sin a, whereas the displacement response varies like sinc a. Maximum coupling is achieved when the PWAS length equals the half wavelength of a particular Lamb wave mode. Since Lamb wave modes wavelengths vary with frequency, the tuning of certain modes at certain frequencies can thus be achieved. Tuning curves are derived and verified against experimental results. A particular S 0 mode ‘sweet spot’ is found at 300 kHz for a 7-mm PWAS attached to a 1.6-mm aluminum plate. Crack detection via the pulse echo technique using the phased array principle and tuned S 0 mode Lamb waves is demonstrated as an effective structural health monitoring method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasonic Guided Waves in Solid Media
Rose, J. L. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107273610 · Cited by 1,496
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Malekloo, A., Ozer, E., AlHamaydeh, M., & Girolami, M. (2022) · Structural Health Monitoring · doi:10.1177/14759217211036880 · Cited by 607
An overview of lead-free piezoelectric materials and devices
Wei, H., Wang, H., Xia, Y., Cui, D., Shi, Y., Dong, M., Liu, C., Ding, T., Zhang, J., Ma, Y., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04515a · Cited by 393
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Metadata
- Authors
- Giurgiutiu, V.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 16
- Issue
- 4
- Pages
- 291-305
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2030262987
- Cited by
- 942
- References
- 0
- FWCI
- 43.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tuned Lamb Wave Excitation and Detection with Piezoelectric Wafer Active Sensors for Structural Health Monitoring. https://app.cochat.ai/papers/10.1177/1045389x05050106
- The paper
- Giurgiutiu, V. (2005). Tuned Lamb Wave Excitation and Detection with Piezoelectric Wafer Active Sensors for Structural Health Monitoring. Journal of Intelligent Material Systems and Structures. https://doi.org/10.1177/1045389x05050106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.