Optimal Placement of Piezoelectric Actuators and Sensors for Detecting Damage in Plate Structures
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We propose a novel approach for optimal actuator and sensor placement for active sensing-based structural health monitoring. Of particular interest is the optimization of actuator—sensor arrays making use of ultrasonic wave propagation for detecting damage in thin plate-like structures. Using a detection theory framework, we establish the optimum configuration as the one that minimizes Bayes risk. The detector incorporates a statistical model of the active sensing process that accounts for both reflection and attenuation features, implements pulse-echo and pitch-catch actuation schemes, and takes into account line-of-site. The optimization space was searched using a genetic algorithm with a time-varying mutation rate. For verification, we densely instrumented a concave-shaped plate and applied artificial, reversible damage to a large number of randomly generated locations, acquiring active sensing data for each location. We then used the algorithm to predict optimal subsets of the dense array. The predicted optimal arrangements proved to be among the top performers when compared to large sets of randomly generated arrangements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Genetic Algorithms
Mitchell, M. (1996) · doi:10.7551/mitpress/3927.001.0001 · Cited by 11,340
Cited by
Structural health monitoring: Closing the gap between research and industrial deployment
Cawley, P. (2018) · Structural Health Monitoring · doi:10.1177/1475921717750047 · Cited by 423
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
“Flynn and Todd [35] proposed an approach for optimal actuator and sensor placement for active sensing-based SHM.”
BackgroundIsmail, Z., Mustapha, S., & Tarhini, H. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106523 · Cited by 16
Metadata
- Authors
- Flynn, E. B., & Todd, M. D.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2009-06-04
- Volume
- 21
- Issue
- 3
- Pages
- 265-274
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2131142166
- Cited by
- 81
- References
- 1
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Placement of Piezoelectric Actuators and Sensors for Detecting Damage in Plate Structures. https://app.cochat.ai/papers/10.1177/1045389x09338080
- The paper
- Flynn, E. B., & Todd, M. D. (2010). Optimal Placement of Piezoelectric Actuators and Sensors for Detecting Damage in Plate Structures. Journal of Intelligent Material Systems and Structures. https://doi.org/10.1177/1045389x09338080
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.