Coupled Electro-Mechanical Analysis of Adaptive Material Systems — Determination of the Actuator Power Consumption and System Energy Transfer
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This article presents a coupled electro-mechanical analysis of piezoelectric ceramic (PZT) actuators integrated in mechanical systems to determine the actuator power consumption and energy transfer in the electro-mechanical systems. For a material system with integrated PZT actua tors, the power consumed by the PZT actuators consists of two parts: the energy used to drive the system, which is dissipated in terms of heat as a result of the structural damping, and energy dissi pated by the PZT actuators themselves because of their dielectric loss and internal damping. The coupled analysis presented herein uses a simple model, a PZT actuator-driven one-degree-of- freedom spring-mass-damper system, to illustrate the methodology used to determine the actuator power consumption and energy flow in the coupled electro-mechanical systems. This method can be applied to more complicated mechanical structures or systems, such as a fluid-loaded shell for active structural acoustic control. The determination of the actuator power consumption can be very im portant in the design and application of intelligent material systems and structures and of particular relevance to designs that must be optimized to reduce mass and energy consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
Fundamentals of Piezoelectricity
(2006) · Advances in Industrial Control · doi:10.1007/1-84628-332-9_2 · Cited by 1,149
Fundamentals on Piezoelectricity
Arnau, A., & Soares, D. (2004) · Piezoelectric Transducers and Applications · doi:10.1007/978-3-662-05361-4_1 · Cited by 682
An Impedance Method for Dynamic Analysis of Active Material Systems
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Vibration and Acoustics · doi:10.1115/1.2930387 · Cited by 210
Self-citation
Cited by
Impedance-Based Health Monitoring of Civil Structural Components
Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2000)6:4(153 · Cited by 460
Structural Health Monitoring by Piezo-Impedance Transducers. I: Modeling
Bhalla, S., & Soh, C. K. (2004) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2004)17:4(154 · Cited by 351
Na, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Improving Accessibility of the Impedance-Based Structural Health Monitoring Method
Peairs, D. M., Park, G., & Inman, D. J. (2004) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x04039914 · Cited by 278
Ju, M., Dou, Z., Li, J.-W., Qiu, X., Shen, B., Zhang, D., Yao, F.-Z., Gong, W., & Wang, K. (2023) · Sensors · doi:10.3390/s23010543 · Cited by 277
“were the first to propose the concept of the electromechanical impedance for the EMI system and suggested 1-DOF free-body diagram of a PZT–structure system to explain the interaction between the PZT and the host structure [63,64].”
Background
Metadata
- Authors
- Liang, C., Sun, F. P., & Rogers, C. A.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 1994-01
- Volume
- 5
- Issue
- 1
- Pages
- 12-20
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2018852350
- Cited by
- 790
- References
- 4
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.