The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Impedance-Based Health Monitoring of Civil Structural Components
Abstract
This paper presents experimental evidence on the use of the impedance-based health-monitoring technique on components typical of civil structures. The basic principle behind this technique is to utilize high-frequency structural excitations (typically >30 kHz) through a surface-bonded piezoelectric sensor/actuator to detect changes in structural point impedance due to the presence of damage. Real-time damage detection on composite-reinforced concrete walls was investigated and the capability of this technique to detect imminent damage, well in advance of actual failure, was confirmed. Concepts that directly applied to this technique itself, such as effects of boundary condition changes and the effects of temperature changes, were also investigated. Experimental investigations were carried out on a 1/4-scale bridge element and a pipe joint commonly found in civil structures, to verify robustness of the technique to changes in environmental conditions. Data collected from the tests demonstrate the capability and the effectiveness of this technology to monitor the condition of various civil structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Summary Review of Vibration-Based Damage Identification Methods
Doebling, S. W., Farrar, C. R., & Prime, M. B. (1998) · The Shock and Vibration Digest · doi:10.1177/058310249803000201 · Cited by 2,823
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790
A Self-Sensing Piezoelectric Actuator for Collocated Control
Dosch, J. J., Inman, D. J., & Garcia, E. (1992) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9200300109 · Cited by 767
Self-citationImpedance-Based Structural Health Monitoring for Temperature Varying Applications.
PARK, G., KABEYA, K., CUDNEY, H. H., & INMAN, D. J. (1999) · JSME International Journal Series A · doi:10.1299/jsmea.42.249 · Cited by 284
Self-citationLocal-area health monitoring of aircraft via piezoelectric actuator/sensor patches
Chaudhry, Z. A., Joseph, T., Sun, F. P., & Rogers, C. A. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.208264 · Cited by 133
Cited by
A Summary Review of Wireless Sensors and Sensor Networks for Structural Health Monitoring
Lynch, J. P. (2006) · The Shock and Vibration Digest · doi:10.1177/0583102406061499 · Cited by 1,533
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003) · The Shock and Vibration Digest · doi:10.1177/05831024030356001 · Cited by 1,060
Self-citationMalekloo, A., Ozer, E., AlHamaydeh, M., & Girolami, M. (2022) · Structural Health Monitoring · doi:10.1177/14759217211036880 · Cited by 607
An overview of wireless structural health monitoring for civil structures
Lynch, J. P. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1932 · Cited by 413
Damage identification using inverse methods
Friswell, M. I. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1930 · Cited by 376
Metadata
- Authors
- Park, G., Cudney, H. H., & Inman, D. J.
- Venue
- Journal of Infrastructure Systems
- Published
- 2000-12
- Volume
- 6
- Issue
- 4
- Pages
- 153-160
- ISSN
- 1076-0342 (ISSN-L)
- 1943-555X
- DOI
- 10.1061/(asce)1076-0342(2000)6:4(153
- OpenAlex
- W2048670932
- Cited by
- 460
- References
- 5
- FWCI
- 15.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance-Based Health Monitoring of Civil Structural Components. https://app.cochat.ai/papers/10.1061/(asce)1076-0342(2000)6:4(153
- The paper
- Park, G., Cudney, H. H., & Inman, D. J. (2000). Impedance-Based Health Monitoring of Civil Structural Components. Journal of Infrastructure Systems. https://doi.org/10.1061/(asce)1076-0342(2000)6%3A4(153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.