Identifying Severe Sepsis via Electronic Surveillance
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An electronic sepsis surveillance system (ESSV) was developed to identify severe sepsis and determine its time of onset. ESSV sensitivity and specificity were evaluated during an 11-day prospective pilot and a 30-day retrospective trial. ESSV diagnostic alerts were compared with care team diagnoses and with administrative records, using expert adjudication as the standard for comparison. ESSV was 100% sensitive for detecting severe sepsis but only 62.0% specific. During the pilot, the software identified 477 patients, compared with 18 by adjudication. In the 30-day trial, adjudication identified 164 severe sepsis patients, whereas ESSV detected 996. ESSV was more sensitive but less specific than care team or administrative data. ESSV-identified time of severe sepsis onset was a median of 0.00 hours later than adjudication (interquartile range = 0.05). The system can be a useful tool when implemented appropriately but lacks specificity, largely because of its reliance on discreet data fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Implementation of a real-time computerized sepsis alert in nonintensive care unit patients*
Sawyer, A. M., Deal, E. N., Labelle, A. J., Witt, C., Thiel, S. W., Heard, K., Reichley, R. M., Micek, S. T., & Kollef, M. H. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318205df85 · Cited by 169 · cited 2×
“Both incidence and cost are likely higher than the reported numbers because providers do not always recognize or document the condition appropriately.(8,12,13) Alternative tools to aid providers in diagnosing severe sepsis, such as manual screening forms or automated screening performed through the electronic medical…”
BackgroundProspective Trial of Real-Time Electronic Surveillance to Expedite Early Care of Severe Sepsis
Nelson, J. L., Smith, B. L., Jared, J. D., & Younger, J. G. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.12.008 · Cited by 122
Hooper, M. H., Weavind, L., Wheeler, A. P., Martin, J. B., Gowda, S. S., Semler, M. W., Hayes, R. M., Albert, D. W., Deane, N. B., Nian, H., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318250a887 · Cited by 121 · cited 2×
“Both incidence and cost are likely higher than the reported numbers because providers do not always recognize or document the condition appropriately.(8,12,13) Alternative tools to aid providers in diagnosing severe sepsis, such as manual screening forms or automated screening performed through the electronic medical…”
Background
Cited by
Sendak, M. P., Ratliff, W., Sarro, D., Alderton, E., Futoma, J., Gao, M., Nichols, M., Revoir, M., Yashar, F., Miller, C., et al. (2020) · JMIR Medical Informatics · doi:10.2196/15182 · Cited by 287
“At that time, there were successful reports of sepsis CDS algorithms [29], but there was no validated machine learning method to predict sepsis among adult patients presenting to the ED.”
BackgroundWhiles, B. B., Deis, A. S., & Simpson, S. Q. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002262 · Cited by 213
Self-citationPruinelli, L., Westra, B. L., Yadav, P., Hoff, A., Steinbach, M., Kumar, V., Delaney, C. W., & Simon, G. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000002949 · Cited by 194
Ginestra, J. C., Giannini, H. M., Schweickert, W. D., Meadows, L., Lynch, M. J., Pavan, K., Chivers, C. J., Draugelis, M., Donnelly, P. J., Fuchs, B. D., et al. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003803 · Cited by 159
Identifying Patients With Sepsis on the Hospital Wards
Bhattacharjee, P., Edelson, D. P., & Churpek, M. M. (2017) · Chest · doi:10.1016/j.chest.2016.06.020 · Cited by 120
Metadata
- Authors
- Brandt, B. N., Gartner, A. B., Moncure, M., Cannon, C. M., Carlton, E., Cleek, C., Wittkopp, C., & Simpson, S. Q.
- Venue
- American Journal of Medical Quality
- Published
- 2014-06-26
- Volume
- 30
- Issue
- 6
- Pages
- 559-565
- ISSN
- 1062-8606 (ISSN-L)
- 1555-824X
- OpenAlex
- W2139517484
- Cited by
- 27
- References
- 3
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.