CoChat

An Evaluation of Nuclear Power Plant Safety Parameter Display Systems

Woods, David D., Wise, John A., Hanes, Lewis F. · 1981 · Proceedings of the Human Factors Society Annual Meeting
Cited by 94

The DOI matches its Crossref record.

Abstract

Two proposed safety parameter display systems, of the type to be required in nuclear power plant control rooms, were evaluated using a training simulator and experienced crews undergoing refresher training. A decision analysis approach was used. The discussion addresses the effectiveness of the training situation as an evaluation tool and methodological issues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/107118138102500127

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 94

Metadata

Authors
Woods, D. D., Wise, J. A., & Hanes, L. F.
Venue
Proceedings of the Human Factors Society Annual Meeting
Published
1981-10
Volume
25
Issue
1
Pages
110-114
ISSN
0163-5182 (ISSN-L)
OpenAlex
W1491810677
Cited by
94
References
0
FWCI
2.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Evaluation of Nuclear Power Plant Safety Parameter Display Systems. https://app.cochat.ai/papers/10.1177/107118138102500127
The paper
Woods, D. D., Wise, J. A., & Hanes, L. F. (1981). An Evaluation of Nuclear Power Plant Safety Parameter Display Systems. Proceedings of the Human Factors Society Annual Meeting. https://doi.org/10.1177/107118138102500127

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.