Challenges and Recent Developments in Hearing Aids: Part I. Speech Understanding in Noise, Microphone Technologies and Noise Reduction Algorithms
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This review discusses the challenges in hearing aid design and fitting and the recent developments in advanced signal processing technologies to meet these challenges. The first part of the review discusses the basic concepts and the building blocks of digital signal processing algorithms, namely, the signal detection and analysis unit, the decision rules, and the time constants involved in the execution of the decision. In addition, mechanisms and the differences in the implementation of various strategies used to reduce the negative effects of noise are discussed. These technologies include the microphone technologies that take advantage of the spatial differences between speech and noise and the noise reduction algorithms that take advantage of the spectral difference and temporal separation between speech and noise. The specific technologies discussed in this paper include first-order directional microphones, adaptive directional microphones, second-order directional microphones, microphone matching algorithms, array microphones, multichannel adaptive noise reduction algorithms, and synchrony detection noise reduction algorithms. Verification data for these technologies, if available, are also summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nilsson, M., Soli, S. D., & Sullivan, J. A. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.408469 · Cited by 2,078
Temporal information in speech: acoustic, auditory and linguistic aspects
Rosen, S. (1992) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1992.0070 · Cited by 1,130 · cited 2×
“The rationale is that the amplitude of speech has a constantly varying envelope with a modulation rate between 2 and 50 Hz (Rosen, 1992), with a center modulation rate of 4 to 6 Hz (Houtgast and Steeneken, 1985).”
BackgroundFesten, J. M., & Plomp, R. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400247 · Cited by 856 · cited 1×
“This means that for a given background noise, the speech needs to be as much as 30 dB higher for people with hearing loss to achieve the same level of understanding as people with normal hearing (Baer and Moore, 1994; Dirks et al., 1982; Duquesnoy, 1983; Eisenberg et al., 1995; Festen and Plomp, 1990; Killion, 1997a;…”
BackgroundHoutgast, T., & Steeneken, H. J. M. (1985) · The Journal of the Acoustical Society of America · doi:10.1121/1.392224 · Cited by 671
Peters, R. W., Moore, B. C. J., & Baer, T. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.421128 · Cited by 315
Duquesnoy, A. J. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.389859 · Cited by 282
Stone, M. A., & Moore, B. C. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199906000-00002 · Cited by 171
What can the pure-tone audiogram tell us about a patientʼs SNR loss?
Killion, M. C., & Niquette, P. A. (2000) · The Hearing Journal · doi:10.1097/00025572-200003000-00006 · Cited by 156
Hawkins, D. B., & Yacullo, W. S. (1984) · Journal of Speech and Hearing Disorders · doi:10.1044/jshd.4903.278 · Cited by 144
Noise reduction in hearing aids: a review.
Levitt, H. (2001) · PubMed · Cited by 105
Speech Perception in Noise: Directional Microphones versus Frequency Modulation (FM) Systems
Lewis, M. S., Crandell, C. C., Valente, M., & Enrietto, J. A. (2004) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.15.6.4 · Cited by 104 · cited 1×
“It is worthy of noting that although array microphones can provide up to 7 to 8 dB of improvement in SNR, FM systems have been shown to provide 10 to 20 dB of improvement (Crandell and Smaldino, 2001; Lewis et al., 2004).”
BackgroundBoymans, M., & Dreschler, W. A. (2000) · International Journal of Audiology · doi:10.3109/00206090009073090 · Cited by 103
Speech enhancement based conceptually on auditory evidence
Cheng, Y. M., & O’Shaughnessy, D. D. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.134427 · Cited by 97 · cited 1×
“Noise reduction algorithms are different from the speech enhancement algorithms in that noise reduction algorithms aim to reduce noise interference whereas speech enhancement algorithms are designed to enhance the contrast between vowel and consonants (Bunnel, 1990; Cheng and O’Shaughnessy, 1991).”
BackgroundTolerable Hearing Aid Delays. II. Estimation of Limits Imposed During Speech Production
Stone, M. A., & Moore, B. C. J. (2002) · Ear and Hearing · doi:10.1097/00003446-200208000-00008 · Cited by 93
Stone, M. A., & Moore, B. C. J. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000058106.68049.9c · Cited by 92
Hearing Aids: Past, Present, Future: Moving Toward Normal Conversations in Noise
Killion, M. C. (1997) · British Journal of Audiology · doi:10.3109/03005364000000016 · Cited by 64
Cited by
It's Not a Bug, It's a Feature: Functional Materials in Insects
Schroeder, T. B. H., Houghtaling, J., Wilts, B. D., & Mayer, M. (2018) · Advanced Materials · doi:10.1002/adma.201705322 · Cited by 201
EskandariNasab, M., Raeisi, Z., Lashaki, R. A., & Najafi, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-58886-y · Cited by 55
Metadata
- Authors
- Chung, K.
- Venue
- Trends in Amplification
- Publisher
- SAGE Publications
- Published
- 2004-01
- Volume
- 8
- Issue
- 3
- Pages
- 83-124
- ISSN
- 1084-7138 (ISSN-L)
- OpenAlex
- W2066652080
- Cited by
- 189
- References
- 16
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.