A Comparison of ALPHAScreen, TR-FRET, and TRF as Assay Methods for FXR Nuclear Receptors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
New developments in detection technologies are providing a variety of biomolecular screening strategies from which to choose. Consequently, we performed a detailed analysis of both separation-based and non-separation-based formats for screening nuclear receptor ligands. In this study, time-resolved fluorescence resonance energy transfer (TR-FRET), ALPHAScreen, and time-resolved fluorescence (TRF) assays were optimized and compared with respect to sensitivity, reproducibility, and miniaturization capability. The results showed that the ALPHAScreen system had the best sensitivity and dynamic range. The TRF assay was more time consuming because of the number of wash steps necessary. The TR-FRET assay had less interwell variation, most likely because of ratiometric measurement. Both the ALPHAScreen and the TR-FRET assays were miniaturized to 8-microl volumes. Of the photomultiplier tube-based readers, the ALPHAScreen reader (ALPHAQuest) presented the advantage of faster reading times through simultaneous reading with four photomultiplier tubes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Cited by
Shu, X., Lev-Ram, V., Deerinck, T. J., Qi, Y., Ramko, E. B., Davidson, M. W., Jin, Y., Ellisman, M. H., & Tsien, R. Y. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1001041 · Cited by 827
High-throughput screening assays for the identification of chemical probes
Inglese, J., Johnson, R. L., Simeonov, A., Xia, M., Zheng, W., Austin, C. P., & Auld, D. S. (2007) · Nature Chemical Biology · doi:10.1038/nchembio.2007.17 · Cited by 614
Post-translational Modifications Differentially Affect IgG1 Conformation and Receptor Binding
Houde, D., Peng, Y., Berkowitz, S. A., & Engen, J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900540-mcp200 · Cited by 393
High-Throughput Screening: today’s biochemical and cell-based approaches
Blay, V., Tolani, B., Ho, S. P., & Arkin, M. R. (2020) · Drug Discovery Today · doi:10.1016/j.drudis.2020.07.024 · Cited by 387
The Use of AlphaScreen Technology in HTS: Current Status
Eglen, R. M., Reisine, T., Roby, P., Rouleau, N., Illy, C., Bossé, R., & Bielefeld, M. (2008) · Current Chemical Genomics · doi:10.2174/1875397300801010002 · Cited by 260
Self-citation
Metadata
- Authors
- Glickman, J. F., Wu, X., Mercuri, R., Illy, C., Bowen, B. R., He, Y., & Sills, M.
- Venue
- SLAS Discovery
- Publisher
- Elsevier BV
- Published
- 2002-02
- Volume
- 7
- Issue
- 1
- Pages
- 3-10
- ISSN
- 2472-5552 (ISSN-L)
- OpenAlex
- W2080106148
- Cited by
- 128
- References
- 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of ALPHAScreen, TR-FRET, and TRF as Assay Methods for FXR Nuclear Receptors. https://app.cochat.ai/papers/10.1177/108705710200700102
- The paper
- Glickman, J. F., Wu, X., Mercuri, R., Illy, C., Bowen, B. R., He, Y., & Sills, M. (2002). A Comparison of ALPHAScreen, TR-FRET, and TRF as Assay Methods for FXR Nuclear Receptors. SLAS Discovery. https://doi.org/10.1177/108705710200700102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.