Cited by 21Mass Spectrometry Techniques and ApplicationsAnalytical Chemistry and ChromatographyMicrofluidic and Capillary Electrophoresis Applications

High-Resolution Bioactivity Profiling of Mixtures toward the Acetylcholine Binding Protein Using a Nanofractionation Spotter Technology

Open access
Kool, Jeroen, Heus, Ferry, de Kloe, Gerdien, Lingeman, Henk, Smit, August B., Leurs, Rob, Edink, Ewald, De Esch, Iwan J.P. +2 more·2011·SLAS Discovery

Abstract

This study describes the evaluation, validation, and use of contactless postcolumn fractionation of bioactive mixtures with acetylcholine binding protein (AChBP) affinity analysis with help of a spotter technology. The high-resolution fractionation tailors the fractionation frequency to the chromatographic peaks. Postcolumn reagents for AChBP bioaffinity profiling are mixed prior to droplet ejection into 1536-well plates. After an incubation step, microplate reader analysis is used to determine bioactive compounds in a mixture. For ligands tested, a good correlation was found for IC(50)s determined in flow injection analysis mode when compared with traditional radioligand binding assays. After the evaluation and validation, bioaffinity profiling of actual mixtures was performed. The advantage of this "atline" technology using postcolumn bioaffinity analysis when compared to continuous flow online postcolumn bioaffinity profiling is the possibility to choose postcolumn incubation times freely without compromising resolution due to diffusion effects.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1087057111413921

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kool, J., Heus, F., de Kloe, G., Lingeman, H., Smit, A. B., Leurs, R., Edink, E., De Esch, I. J. P., Irth, H., & Niessen, W. M. A.
Affiliations
  • Vrije Universiteit Amsterdam (NL)
  • Amsterdam Neuroscience (NL)
Corresponding author
Kool, Jeroen
Venue
SLAS Discovery
Publisher
Elsevier BV
Published
2011-09
Volume
16
Issue
8
Pages
917-924
ISSN
2472-5552 (ISSN-L)
OpenAlex
W2138635792
Cited by
21
References
21
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2019: 1 · 2017: 1 · 2016: 4 · 2015: 2 · 2014: 1 · 2013: 4 · 2012: 4
FWCI
1.45
Type
journal article
Language
en
Open access
Locations
  • SLAS DISCOVERY (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • VU Research Portal (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
acetylcholine binding protein, droplet ejection, ligand binding, flow injection analysis, microplate reader
MeSH terms
Carrier Proteins, Chromatography, Affinity, Chromatography, High Pressure Liquid, Chemical Fractionation, Ligands, Nicotine, Protein Binding, Pyridines, Radioligand Assay, Recombinant Proteins, Mass Spectrometry, Reproducibility of Results, Flow Injection Analysis, Nicotinic Agonists, Bridged Bicyclo Compounds, Heterocyclic, Nanotechnology, Complex Mixtures, High-Throughput Screening Assays

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›