The Evolution of MALDI-TOF Mass Spectrometry toward Ultra-High-Throughput Screening: 1536-Well Format and Beyond
Open accessThe DOI matches its Crossref record.
Abstract
Mass spectrometry (MS) offers a label-free, direct-detection method, in contrast to fluorescent or colorimetric methodologies. Over recent years, solid-phase extraction-based techniques, such as the Agilent RapidFire system, have emerged that are capable of analyzing samples in <10 s. While dramatically faster than liquid chromatography-coupled MS, an analysis time of 8-10 s is still considered relatively slow for full-diversity high-throughput screening (HTS). Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF) offers an alternative for high-throughput MS detection. However, sample preparation and deposition onto the MALDI target, as well as interference from matrix ions, have been considered limitations for the use of MALDI for screening assays. Here we describe the development and validation of assays for both small-molecule and peptide analytes using MALDI-TOF coupled with nanoliter liquid handling. Using the JMJD2c histone demethylase and acetylcholinesterase as model systems, we have generated robust data in a 1536 format and also increased sample deposition to 6144 samples per target. Using these methods, we demonstrate that this technology can deliver fast sample analysis time with low sample volume, and data comparable to that of current RapidFire assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mapping the dark space of chemical reactions with extended nanomole synthesis and MALDI-TOF MS
Lin, S., Dikler, S., Blincoe, W. D., Ferguson, R. D., Sheridan, R. P., Peng, Z., Conway, D. V., Zawatzky, K., Wang, H., Cernak, T., et al. (2018) · Science · doi:10.1126/science.aar6236 · Cited by 194
Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Sawyer, W. S., Srikumar, N., Carver, J., Chu, P. Y., Shen, A., Xu, A., Williams, A. J., Spiess, C., Wu, C., Liu, Y., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1917383117 · Cited by 55
Smith, R., Brookes, C., Morris, M., & Barran, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c02331 · Cited by 14
Metadata
- Authors
- Haslam, C., Hellicar, J., Dunn, A., Fuetterer, A., Hardy, N., Marshall, P., Paape, R., Pemberton, M., Resemannand, A., & Leveridge, M.
- Venue
- SLAS Discovery
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 21
- Issue
- 2
- Pages
- 176-186
- ISSN
- 2472-5552 (ISSN-L)
- OpenAlex
- W2335877792
- Cited by
- 141
- References
- 0
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Evolution of MALDI-TOF Mass Spectrometry toward Ultra-High-Throughput Screening: 1536-Well Format and Beyond. https://app.cochat.ai/papers/10.1177/1087057115608605
- The paper
- Haslam, C., Hellicar, J., Dunn, A., Fuetterer, A., Hardy, N., Marshall, P., Paape, R., Pemberton, M., Resemannand, A., & Leveridge, M. (2016). The Evolution of MALDI-TOF Mass Spectrometry toward Ultra-High-Throughput Screening: 1536-Well Format and Beyond. SLAS Discovery. https://doi.org/10.1177/1087057115608605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.