Heart Rate Variability and 24-hour Minimum Heart Rate
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) indices based on 24-hr electrocardiograph recordings have been used in clinical research studies to assess the aggregate activity of the autonomic nervous system. Although 24-hr HRV is generally considered noninvasive, use in research protocols typically involves considerable data collection and processing expenses and substantial participant burden. The purposes of this research methods evaluation were to describe the relationships between 24-hr minimum heart rate (HR) and several 24-hr time domain HRV indices (Ln SDNN, Ln SDANN, Ln SDNNIDX, Ln RMSSD, and Logit50) across several research data sets (normal women, normal men, children enrolled in a study of recurrent abdominal pain, women with irritable bowel syndrome, sudden cardiac arrest survivors, and heart failure patients) and to explore the possibility that 24-hr minimum HR might serve as a simpler alternative or adjunct to HRV measures in some situations. The correlations of global HRV measures (e.g., Ln SDNN, Ln SDANN) with 24-hr minimum HR were consistently larger (typical r ~ -.80) than with average HR (typical r ~ -.50). In repeated measurements, change in minimum HR was also correlated with change in general HRV (typical r ~ -.60). However, modest differentiation of minimum HR and HRV measures was noted in patients taking certain classes of cardiac medications (e.g., anti-arrhythmics, beta blockers). Twenty-four-hour minimum HR is correlated with general time domain HRV measures and might be useful as a simpler proxy, surrogate, or auxiliary variable in some clinical research applications, especially those in which participants are not receiving cardiac medications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“there remains a knowledge gap associating HRV values with incidence or severity of gastrointestinal disorders despite several published reviews pertaining to IBS and none assessing IBD studies (16–20).”
From Alterations in Heart Rate Variability Associated With Irritable Bowel Syndrome or Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis (2021) · cites this paper as [17]
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
(2002) · Cited by 13,211
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079 · cited 1×
“For example, spectral analysis–based measures of HRV can describe physiologically interpretable rhythmic phenomena in HP sequences (Akselrod et al., 1981; Ori, Monir, Weiss, Sayhouni, & Singer, 1992).”
BackgroundThe Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962 · cited 1×
“A well-correlated auxiliary variable such as minimum HR measured at baseline might be used as a controlling covariate in an ANCOVA of an HRV outcome measure to reduce subject heterogeneity in an intervention experimental design (Anderson et al., 1980; Fleiss, 1986).”
MethodThe Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
Heart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290
Heart rate and cardiovascular mortality: The Framingham study
Kannel, W. B., Kannel, C., Paffenbarger, R. S., & Cupples, L. A. (1987) · American Heart Journal · doi:10.1016/0002-8703(87)90666-1 · Cited by 1,290
Research works printed but not linked: 2
- Cochran, W. G., 1977, Sampling techniques
- McMillan, D., 2005, Cardiac nursing, 527
Cited by
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
“Maximum HR is weakly and inconsistently correlated with these time-domain measures (38).”
BackgroundOrsila, R., Virtanen, M., Luukkaala, T. H., Tarvainen, M. P., Karjalainen, P. A., Viik, J., Savinainen, M., & Nygård, C. (2008) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2008.11076767 · Cited by 133
Gąsior, J. S., Sacha, J., Pawłowski, M., Zieliński, J., Jelen, P., Tomik, A., Książczyk, T. M., Werner, B., & Dąbrowski, M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01495 · Cited by 109
Sadowski, A., Dunlap, C., Lacombe, A., & Hanes, D. (2021) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000000275 · Cited by 45
Farmer, A. D., Coen, S. J., Kano, M., Weltens, N., Ly, H. G., Botha, C. A., Paine, P., Oudenhove, L. V., & Aziz, Q. (2014) · PubMed Central · Cited by 34
Metadata
- Authors
- Burr, R. L., Motzer, S. A., Chen, W., Cowan, M. J., Shulman, R. J., & Heitkemper, M. M.
- Affiliations
- University of Washington (US)
- University of California, San Francisco (US)
- University of California, Los Angeles (US)
- Baylor College of Medicine (US)
- Corresponding author
- Burr, Robert L.
- Venue
- Biological Research For Nursing
- Publisher
- SAGE Publications
- Published
- 2006-04
- Volume
- 7
- Issue
- 4
- Pages
- 256-267
- ISSN
- 1099-8004 (ISSN-L)
- 1552-4175
- OpenAlex
- W2031718697
- Cited by
- 22
- References
- 44
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 3 · 2018: 2 · 2017: 1 · 2014: 1 · 2013: 2
- FWCI
- 0.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Biological Research For Nursing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01nr001970-05, 1r55nr002429-01a1, 5r01hl060042-03)
- National Heart, Lung, and Blood Institute (HL60042)
- National Institute of Nursing Research (NR01970, NR02429, NR04101, R01NR005337, NR05337)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- heart rate variability, autonomic nervous system activity, time-domain HRV, SDNN, SDANN, RMSSD, cardiovascular drugs, antiarrhythmic drugs, beta-blockers, heart failure, irritable bowel syndrome, recurrent abdominal pain, participant burden
- MeSH terms
- Adult, Analysis of Variance, Autonomic Nervous System Diseases, Child, Data Interpretation, Statistical, Female, Heart Arrest, Heart Failure, Heart Rate, Humans, Male, Predictive Value of Tests, Recurrence, Reference Values, Research Design, Time Factors, Vagus Nerve, Electrocardiography, Ambulatory, Abdominal Pain, Logistic Models, Irritable Bowel Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart Rate Variability and 24-hour Minimum Heart Rate. https://app.cochat.ai/papers/10.1177/1099800405285268
- The paper
- Burr, R. L., Motzer, S. A., Chen, W., Cowan, M. J., Shulman, R. J., & Heitkemper, M. M. (2006). Heart Rate Variability and 24-hour Minimum Heart Rate. Biological Research For Nursing. https://doi.org/10.1177/1099800405285268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.