Rapid Central Vein Assessment (RaCeVA): A systematic, standardized approach for ultrasound assessment before central venous catheterization
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Ultrasound technology has revolutionized the practice of safer vascular access, for both venous and arterial cannulation. The ability to visualize underlying structures of the chest, neck, and upper/lower extremities provides for greater success, speed, and safety with all vascular access procedures. Ultrasound not only yields superior procedural advantages but also provides a platform to perform a thorough assessment of the vascular structures to evaluate vessel health, viability, size, and patency, including the location of other important and best avoided anatomical structures—prior to performing any procedures. Such assessment is best performed using a systematic and standardized approach, as the Rapid Central Vein Assessment, described in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834 · cited 3×
“US is a powerful tool for assisting the operator in many aspects of the procedure: (1) pre-procedural US assessment of the vascular anatomy provides a rationale choice of the venous access most likely to be associated with an optimal clinical outcome; (2) real-time, US-guided puncture and cannulation of the vein reduc…”
Self-citationPittiruti, M., Hamilton, H., Biffi, R., MacFie, J., & Pertkiewicz, M. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.03.015 · Cited by 698 · cited 1×
“US is a powerful tool for assisting the operator in many aspects of the procedure: (1) pre-procedural US assessment of the vascular anatomy provides a rationale choice of the venous access most likely to be associated with an optimal clinical outcome; (2) real-time, US-guided puncture and cannulation of the vein reduc…”
Self-citationSaugel, B., Scheeren, T. W. L., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1814-y · Cited by 481 · cited 4×
“There are numerous publications 1,3–14, 17–”
InfluentialThe comet-tail artifact: an ultrasound sign ruling out pneumothorax
Lichtenstein, D., Mezière, G., Biderman, P., & Gepner, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050862 · Cited by 466
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182407cd8 · Cited by 321
Association of Anaesthetists of Great Britain and Ireland: Safe vascular access 2016
Bodenham (Chair), A., Babu, S., Bennett, J., Binks, R., Fee, P., Fox, B., Johnston, A. J., Klein, A. A., Langton, J. A., Mclure, H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13360 · Cited by 309
Moureau, N., Lamperti, M., Kelly, L. J., Dawson, R., Elbarbary, M., van Boxtel, A. J. H., & Pittiruti, M. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes499 · Cited by 235 · cited 1×
“1,4,5,8,9,11,12,14,21,22,25,26,28,44 It guides the clinician to evaluate the current state of vessel health, determining suitability of the veins, and to follow a pre-determined pathway that will lead to the best decision for the patient.”
Self-citationReal-time Two-dimensional Ultrasound Guidance for Central Venous Cannulation: A Meta-analysis
Wu, S.-Y., Ling, Q., Cao, L.-H., Wang, J., Xu, M.-X., & Zeng, W.-A. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827bd172 · Cited by 213
Zieleskiewicz, L., Muller, L., Lakhal, K., Meresse, Z., Arbelot, C., Bertrand, P.-M., Bouhemad, B., Cholley, B., Demory, D., Duperret, S., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3952-5 · Cited by 207 · cited 3×
“US is a powerful tool for assisting the operator in many aspects of the procedure: (1) pre-procedural US assessment of the vascular anatomy provides a rationale choice of the venous access most likely to be associated with an optimal clinical outcome; (2) real-time, US-guided puncture and cannulation of the vein reduc…”
Cited by
Lamperti, M., Biasucci, D. G., Disma, N., Pittiruti, M., Breschan, C., Vailati, D., Subert, M., Traškaitė, V., Macas, A., Estebe, J.-P., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001180 · Cited by 316
Self-citationAssociation of Anaesthetists guidelines: safe vascular access 2025
Johnston, A. J., Simpson, M. J., McCormack, V., Barton, A., Bennett, J., Chalisey, A., Crane, J., Curry, S., Laycock, H., Patel, D., et al. (2025) · Anaesthesia · doi:10.1111/anae.16727 · Cited by 32
Metadata
- Authors
- Spencer, T. R., & Pittiruti, M.
- Venue
- The Journal of Vascular Access
- Publisher
- SAGE Publications
- Published
- 2018-10-04
- Volume
- 20
- Issue
- 3
- Pages
- 239-249
- ISSN
- 1129-7298 (ISSN-L)
- 1724-6032
- OpenAlex
- W2895656507
- Cited by
- 203
- References
- 25
- FWCI
- 17.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.