The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Mould and Winter Indoor Relative Humidity in Low Income Households in England
Open accessAbstract
This paper examines the extent to which variation in heating-season, indoor relative humidity (RH) and mould occurrence in English households is explained by dwelling and household characteristics. It is based on analysis of data from a national study of England's Home Energy Efficiency scheme ( Warm Front) which provides grants for energy efficiency improvements to vulnerable households. Surveys were undertaken of dwellings and households participating in the scheme in five urban areas. Half-hourly living room and main bedroom temperatures and RH measurements were recorded for two to four weeks in a subset of dwellings (no.=1604) over the winters of 2001–02 and 2002-03. For each dwelling, regression of indoor vapour pressure excess on outdoor temperature was used to obtain estimates of daily living room and bedroom indoor vapour pressure under standardised conditions (outdoor temperature of 5°C and 80% RH), from which standardised values of indoor relative humidity were derived. We present evidence on the relationship between mould severity and standardised relative humidity, and between both these parameters and household and dwelling characteristics, including Warm Frontimprovements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Inadequately heated houses are more likely to be damp, which can lead to the growth of mold.
“Inadequately heated houses are more likely to be damp, which can lead to the growth of mold (121)”
From Review of the Impact of Housing Quality on Inequalities in Health and Well-Being (2023) · cites this paper as [121]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Excess winter mortality in Europe: a cross country analysis identifying key risk factors
Healy, J. (2003) · Journal of Epidemiology & Community Health · doi:10.1136/jech.57.10.784 · Cited by 623
Effects of damp and mould in the home on respiratory health: a review of the literature
Peat, J. K., Dickerson, J., & Li, J. J. (1998) · Allergy · doi:10.1111/j.1398-9995.1998.tb03859.x · Cited by 346
Bornehag, C., Sundell, J., Bonini, S., Čustović, A., Malmberg, P., Skerfving, S., Sigsgaard, T., & Verhoeff, A. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00240.x · Cited by 313
Cold—an underrated risk factor for health
Mercer, J. B. (2003) · Environmental Research · doi:10.1016/s0013-9351(02)00009-9 · Cited by 237
Determinants of winter indoor temperatures in low income households in England
Oreszczyn, T., Hong, S. H., Ridley, I. A., & Wilkinson, P. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2005.06.006 · Cited by 232
Self-citationPasanen, A. ‐., Kasanen, J.-P., Rautiala, S., et al. (2000) · International Biodeterioration & Biodegradation · doi:10.1016/s0964-8305(00)00093-7 · Cited by 169
Cold comfort: the social and environmental determinants of excess winter death in England, 1986-1996
Wilkinson, P., Landon, M., Armstrong, B., Stevenson, S., & McKee, M. (2001) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 165
Self-citationIndex of Multiple Deprivation 2004
Communities (2014) · Cited by 92
Geography for the 2001 Census in England and Wales.
MARTIN, D. J. (2002) · PubMed · Cited by 66
Condensation Targeter II: Modelling surface relative humidity to predict mould growth in dwellings
Oreszczyn, T., & Pretlove, S. (1999) · Building Services Engineering Research and Technology · doi:10.1177/014362449902000307 · Cited by 30
Self-citationDavies, M., Ucci, M., McCarthy, M., et al. (2004) · International Journal of Ventilation · doi:10.1080/14733315.2004.11683911 · Cited by 19
Sasieni, P. D. (1995) · Stata technical bulletin · Cited by 10
Code of practice for control of condensation in buildings
(2013) · doi:10.3403/30171811 · Cited by 5
Flagged first, then by citations
Research works printed but not linked: 13
- Raw G, 2001, Building Regulation, Health and Safety
- 2003, BMA: Housing and health: building for the future
- BS EN ISO 13788, 2002, Internal surface temperature to avoid critical surface humidity and interstitial condensation – calculation methods
- Department of Trade and Industry, 2001, UK Fuel Poverty Strategy
- BRECSU (on behalf of DEFRA), 2001, The Government's Standard Assessment Procedure for Energy Rating of Dwellings
- Shorrock L, 2003, Domestic energy fact file 2003 (BR 457)
- English House Condition Survey 1996, 2000, Energy Report
- Hong SH, Proc. 25th Air Infiltration and Ventilation Centre Conference: Ventilation and Retrofitting, 7
- Martin D, 2002, Population Trends, 108, 7
- Sasieni P, 2003, Stata Technical Bulletin, 24
- Stephen RK, 1998, Air tightness in UK dwellings: BRE's test results and their significance
- ODPM, 2003, Statistical evidence to support the housing health and safety rating system. Vols 1–3: Project report, summary of results and technical appendix
- ODPM, 2000, The Building Regulations Approved Document Part F: Ventilation
Cited by
Sorted by citations
Review of the Impact of Housing Quality on Inequalities in Health and Well-Being
Howden-Chapman, P., Bennett, J., Edwards, R., Jacobs, D., Nathan, K., & Ormandy, D. (2023) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-071521-111836 · Cited by 153
Ehsan, S., Abbas, F., Ibrahim, M., Ahmad, B., & Farooque, A. A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18052535 · Cited by 36
Metadata
- Authors
- Oreszczyn, T., Ridley, I., Hong, S. H., Wilkinson, P., & Warm Front Study Group
- Affiliations
- University College London (GB)
- London School of Hygiene & Tropical Medicine (GB)
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 2006-04
- Volume
- 15
- Issue
- 2
- Pages
- 125-135
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W1988828319
- Cited by
- 78
- References
- 13
- Citations by year
- 2025: 9 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 5 · 2020: 6 · 2019: 4 · 2018: 1 · 2017: 6 · 2015: 7 · 2014: 3 · 2013: 5 · 2012: 6
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
- discovery.ucl.ac.uk
- Locations
- Indoor and Built Environment (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (submittedVersion)
- Funders
- Llywodraeth Cymru
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Pollution › Energy and Environment Impacts
- Keywords
- indoor relative humidity, molds, low-income households, heating season, indoor air quality, energy efficiency improvement, household characteristics, housing characteristics, indoor temperature, dampness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review