Characterisation of Volatile Organic Compounds at Hotels in Southern China
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
In the recent years, there has been a dramatic growth in the development of hotels in Southern China to meet the rapid demand of business and tourism industry. The indoor air quality of the hotels has become an important consideration due to a large workforce that is engaged in this industry. The objective of this study was to characterise the volatile organic compounds (VOCs) found in the indoor air in 13 new hotels in Southern China and assess their possible health impact. A 2-day non-simultaneous sampling was carried out in each of the hotels. Decorating materials, cleansing agents and even local regional pollutants outside the hotels could have a contribution and worsen indoor air quality. Toluene level was as high as 498 μg m —3 in a hotel fitted with lots of plywood products. The highest concentrations of methylene chloride (34 μg m —3 ) and total carbonyls (517 μg m —3 ) were detected in a hotel where high VOCs cleansing agents were used in guest rooms. In a hotel located in an industrial centre, acetone concentration of 102 μg m —3 was found. The second highest total VOCs concentration (445 μg m —3 ) was observed in a newly renovated hotel. Wooden interior fixtures and wall panels were identified as the major sources of VOCs and carbonyls found inside the guest rooms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Much higher formaldehyde levels have been reported in Chinese hotel rooms, e.g., 60–290 μg/m3 [51], 114 μg/m3 in new hotels [22], 140 μg/m3 in newly furnished rooms, and 10 μg/m3 in older rooms [52].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [22]
In the citing paper
“Several studies conducted in industrial areas in China have reported high indoor BTEX and TTVOC levels (even though relatively few target VOCs were included) as well as high outdoor levels (averaging 420 μg/m3) [22–24].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [22]
In the citing paper
“We estimated an average ACR of 2.5 hr−1 (range: 0.6–3.7 hr−1), similar to previous studies [22, 76–78].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [22]
Citations
Cites
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Formaldehyde in China: Production, consumption, exposure levels, and health effects
Tang, X., Bai, Y., Duong, A., Smith, M. T., Li, L., & Zhang, L. (2009) · Environment International · doi:10.1016/j.envint.2009.06.002 · Cited by 757
Human reactions to low concentrations of volatile organic compounds
Mølhave, L., Bach, B., & Pedersen, O. F. (1986) · Environment International · doi:10.1016/0160-4120(86)90027-9 · Cited by 441
A review of the emission of VOCs from polymeric materials used in buildings
Yu, C., & Crump, D. (1998) · Building and Environment · doi:10.1016/s0360-1323(97)00055-3 · Cited by 352
Risk in cleaning: chemical and physical exposure
Wolkoff, P., Schneider, T., Kildesø, J., Degerth, R., Jaroszewski, M., & Schunk, H. (1998) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00110-7 · Cited by 287
Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong
Lee, S. C., Li, W.-M., & Yin Chan, L. (2001) · Science of The Total Environment · doi:10.1016/s0048-9697(01)00765-3 · Cited by 263
Self-citationInvestigation of indoor air quality at residential homes in Hong Kong—case study
Lee, S. C., Li, W.-M., & Ao, C.-H. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00435-6 · Cited by 254
Self-citationBuilding Pathology, Investigation of Sick Buildings — VOC Emissions
Yu, C. W. F., & Kim, J. T. (2010) · Indoor and Built Environment · doi:10.1177/1420326x09358799 · Cited by 183
Ho, K. F., Lee, S. C., & Chiu, G. M. Y. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00475-7 · Cited by 172
Self-citationOhura, T., Amagai, T., Shen, X., Li, S., Zhang, P., & Zhu, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.09.022 · Cited by 162
Research works printed but not linked: 14
- United States Environmental Protection Agency (USEPA), 2003, Integrated Risk Information System (IRIS) Benzene (CASRN 71-43-2)
- United States Environmental Protection Agency (USEPA), 1998, Integrated Risk Information System (IRIS) Formaldehyde (CASRN 50-00-0)
- World Health Organization (WHO), 2000, Guidelines for air quality
- Yu C., 2004, IAQ and emissions from wood-based panel products: in Proceedings of the Eighth European Panel Products Symposium
- Ohura T., 2009, Corrected Proof
- Ilgen E., 2001, Indoor versus outdoor sources, the influence of traffic: Atmos Environ, 35, 1235
- United States Environmental Protection Agency (USEPA), 1999, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air Second Edition: Compendium Method TO-14A Determination of Volatile Organic Compounds (VOCs) in Ambient air Using Specially Prepared Canisters with Subsequent Analysis by Gas Chromatography
- United States Environmental Protection Agency (USEPA), 1999, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air Second Edition: Compendium method TO-11A determination of formaldehyde in ambient air using adsorbent cartridge followed by high performance liquid chromatography (HPLC) [active sampling methodology]
- ASTM International: ASTM E741-00, 2006, e1: Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution
- Jiang S., 2002, South China J Prev Med, 28, 61
- Lin J., 2003, Mod Prev Med
- Wang WH: Analysis on indoor air formaldehyde concentration in public places in Guangzhou : J Prev Med 2004;30:80.
- Hkepd, 2003, Guidance Notes for the Management of Indoor Air Quality in Offices and Public Places
- Ciaqc, 2003, Indoor Air Quality Standard GB/ T18883-2002
Cited by
Catalytic removal of formaldehyde at room temperature over supported gold catalysts
Chen, B.-B., Shi, C., Crocker, M., Wang, Y., & Zhu, A.-M. (2013) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2012.11.028 · Cited by 259
Characteristics of indoor air quality in underground metro stations: A critical review
Passi, A., Nagendra, S. M. S., & Maiya, M. P. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107907 · Cited by 110
Wang, Y., Wang, H., Tan, Y., Liu, J., Wang, K., Ji, W., Sun, L., Yu, X., Zhao, J., Xu, B., et al. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118510 · Cited by 70
Lin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Strategies to improve energy and carbon efficiency of luxury hotels in Iran
Salehi, M., Filimonau, V., Asadzadeh, M., & Ghaderi, E. (2020) · Sustainable Production and Consumption · doi:10.1016/j.spc.2020.09.007 · Cited by 67
Metadata
- Authors
- Chan, C. S., Lee, S. C., Chan, W., Ho, K. F., Tian, L., Lai, S. C., Li, Y. S., & Huang, Y.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Chinese University of Hong Kong (HK)
- College of Environmental Science and Engineering, South China University of Technology, Guangzhou, China
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 2011-06-28
- Volume
- 20
- Issue
- 4
- Pages
- 420-429
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W2103371163
- Cited by
- 25
- References
- 28
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2017: 3 · 2016: 3 · 2013: 3 · 2012: 2
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Indoor and Built Environment (publishedVersion)
- The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Funders
- Chinese Academy of Sciences
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- volatile organic compounds, toluene, dichloromethane, carbonyl compounds, acetone, plywood, cleaning agents, health effects, South China
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterisation of Volatile Organic Compounds at Hotels in Southern China. https://app.cochat.ai/papers/10.1177/1420326x11409458
- The paper
- Chan, C. S., Lee, S. C., Chan, W., Ho, K. F., Tian, L., Lai, S. C., Li, Y. S., & Huang, Y. (2011). Characterisation of Volatile Organic Compounds at Hotels in Southern China. Indoor and Built Environment. https://doi.org/10.1177/1420326x11409458
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.