The DOI matches its Crossref record.
Damage Detection in Thin Plates and Aerospace Structures with the Electro-Mechanical Impedance Method
Abstract
The use of the electro-mechanical (E/M) impedance method for health monitoring of thin plates and aerospace structures is described. As a nondestructive evaluation technology, the E/M impedance method allows us to identify the local dynamics of the structure directly through the E/M impedance signatures of piezoelectric wafer active sensors (PWAS) permanently mounted to the structure. An analytical model for 2-D thin-wall structures, which predicts the E/M impedance response at PWAS terminals, was developed and validated. The model accounts for axial and flexural vibrations of the structure and considers both the structural dynamics and the sensor dynamics. Calibration experiments performed on circular thin plates with centrally attached PWAS showed that the presence of damage modifies the high-frequency E/M impedance spectrum causing frequency shifts, peak splitting, and appearance of new harmonics. Overall-statistics damage metrics and probabilistic neural network (PNN) are used to classify the spectral data and identify damage severity. On thin-wall aircraft panels, the presence of damage influences the sensors E/M impedance spectrum. When crack damage is in the PWAS medium field, changes in the distribution of harmonics take place and when crack damage is in the PWAS near field, changes in both the harmonics and the dereverberated response are observed. These effects are successfully classified with PNN and overall-statistics metrics, respectively. This proves that permanently attached PWAS in conjunction with the E/M impedance method can be successfully used in structural health monitoring to detect the presence of incipient damage through the examination and classification of the high-frequency E/M impedance spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development in vibration-based structural damage detection technique
Yan, Y. J., Cheng, L., Wu, Z. Y., & Yam, L. H. (2007) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2006.10.002 · Cited by 614
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Structural Damage Detection Using a Minimum Rank Update Theory
Zimmerman, D. C., & Kaouk, M. (1994) · Journal of Vibration and Acoustics · doi:10.1115/1.2930416 · Cited by 265
Antunes, R. A., Cortez, N. E., Gianesini, B. M., & Vieira Filho, J. (2019) · Sensors · doi:10.3390/s19122802 · Cited by 34
Metadata
- Authors
- Giurgiutiu, V., & Zagrai, A.
- Venue
- Structural Health Monitoring
- Publisher
- SAGE Publications
- Published
- 2005-06
- Volume
- 4
- Issue
- 2
- Pages
- 99-118
- ISSN
- 1475-9217 (ISSN-L)
- 1741-3168
- OpenAlex
- W2022693091
- Cited by
- 229
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Damage Detection in Thin Plates and Aerospace Structures with the Electro-Mechanical Impedance Method. https://app.cochat.ai/papers/10.1177/1475921705049752
- The paper
- Giurgiutiu, V., & Zagrai, A. (2005). Damage Detection in Thin Plates and Aerospace Structures with the Electro-Mechanical Impedance Method. Structural Health Monitoring. https://doi.org/10.1177/1475921705049752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.