Modeling, Simulation, Experimentation, and Compensation of Temperature Effect in Impedance-Based SHM Systems Applied to Steel Pipes
Open accessAbstract
Pipelines have been widely used for the transportation of chemical products, mainly those related to the petroleum industry. Damage in such pipelines can produce leakage with unpredictable consequences to the environment. There are different structural health monitoring (SHM) systems such as Lamb wave, comparative vacuum, acoustic emission, etc. for monitoring such structures. However, those based on piezoelectric sensors and electromechanical impedance technique (EMI) measurements are simple and efficient, and have been applied in a wide range of structures, including pipes. A disadvantage of such technique is that temperature changes can lead to false diagnoses. To overcome this disadvantage, temperature variation compensation techniques are normally incorporated. Therefore, this work has developed a complete study applied to damage detection in pipelines, including an innovative technique for compensating the temperature effect in EMI-based SHM and the modeling of piezoceramics bonded to pipeline structures using finite elements. Experimental results were used to validate the model. Moreover, the compensation method was tested in two steel pipes—healthy and damaged—compensating the temperature effect ranging from −40 °C to +80 °C, with analysis on the frequency range from 5 kHz to 120 kHz. The simulated and experimental results showed that the studies effectively contribute to the SHM area, mainly to EMI-based techniques.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Temperature and structural responses are strongly correlated.
“Temperature and structural responses are strongly correlated [149,150].”
From Effects of Environmental and Operational Conditions on Structural Health Monitoring and Non-Destructive Testing: A Systematic Review (2023) · cites this paper as [149]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,050 · see citing works
Liang, C., Sun, F., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790 · see citing works
Structural Health Monitoring in mainland China: Review and Future Trends
Ou, J., & Li, H. (2010) · Structural Health Monitoring · doi:10.1177/1475921710365269 · Cited by 531 · see citing works
Transducers and Arrays for Underwater Sound
Sherman, C. H., & Butler, J. L. (2007) · Springer eBooks · doi:10.1007/978-0-387-33139-3 · Cited by 484 · see citing works
Smart aggregates: multi-functional sensors for concrete structures—a tutorial and a review
Song, G., Gu, H., & Mo, Y. L. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/3/033001 · Cited by 448 · see citing works
Baptista, F. G., Budoya, D. E., de Almeida, V. A. D., & Ulson, J. A. C. (2014) · Sensors · doi:10.3390/s140101208 · Cited by 287 · see citing works
Impedance-Based Structural Health Monitoring for Temperature Varying Applications.
Park, G., Kabeya, K., Cudney, H. H., et al. (1999) · JSME International Journal Series A · doi:10.1299/jsmea.42.249 · Cited by 284 · see citing works
Improving Accessibility of the Impedance-Based Structural Health Monitoring Method
Peairs, D. M., Park, G., & Inman, D. J. (2004) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x04039914 · Cited by 278 · see citing works
Feasibility of using impedance‐based damage assessment for pipeline structures
Park, G., Cudney, H. H., & Inman, D. J. (2001) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.72 · Cited by 272 · see citing works
Giurgiutiu, V., & Zagrai, A. (2005) · Structural Health Monitoring · doi:10.1177/1475921705049752 · Cited by 229 · see citing works
Yi, T., Huang, H., & Li, H. (2017) · Measurement · doi:10.1016/j.measurement.2017.05.064 · Cited by 195 · see citing works
Sabat, R. G., Mukherjee, B. K., Ren, W., et al. (2007) · Journal of Applied Physics · doi:10.1063/1.2560441 · Cited by 179 · see citing works
Properties of PZT-Based Piezoelectric Ceramics Between -150 and 250 C
Hooker, M. W. (1998) · NASA Technical Reports Server (NASA) · Cited by 172 · see citing works
A New Impedance Measurement System for PZT-Based Structural Health Monitoring
Baptista, F. G., & Filho, J. V. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2018693 · Cited by 148 · see citing works
Koo, K. Y., Park, S., Lee, J.-J., & Yun, C. (2008) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x08088664 · Cited by 140 · see citing works
Impedance-Based Structural Health Monitoring with Artificial Neural Networks
Lopes, V., Park, G., Cudney, H. H., et al. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/h0ev-7pwm-qyhw-e7vf · Cited by 125 · see citing works
Finite element modeling for ultrasonic transducers
Abboud, N. N., Wojcik, G. L., Vaughan, D. K., et al. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.308015 · Cited by 122 · see citing works
RBFN-based temperature compensation method for impedance monitoring in prestressed tendon anchorage
Huynh, T., & Kim, J. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2173 · Cited by 63 · see citing works
Sepehry, N., Shamshirsaz, M., & Abdollahi, F. (2011) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11421814 · Cited by 53 · see citing works
A PZT-Based Electromechanical Impedance Method for Monitoring the Soil Freeze–Thaw Process
Zhang, J., Zhang, C., Xiao, J., et al. (2019) · Sensors · doi:10.3390/s19051107 · Cited by 50 · see citing works
Sepehry, N., Shamshirsaz, M., & Bastani, A. (2010) · Structural Health Monitoring · doi:10.1177/1475921710388338 · Cited by 44 · see citing works
Wandowski, T., Malinowski, P., & Ostachowicz, W. M. (2016) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x16657423 · Cited by 44 · see citing works
Effects of temperature on the electrical impedance of piezoelectric sensors
Krishnamurthy, K., Lalande, F., & Rogers, C. A. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.239033 · Cited by 40 · see citing works
Modelling and Simulation of Impedance-Based Damage Monitoring of Structures
Djemana, M., & Hrairi, M. (2016) · International Journal of Simulation Modelling · doi:10.2507/ijsimm15(3)1.338 · Cited by 38 · see citing works
Cortez, N. E., Filho, J. V., & Baptista, F. G. (2012) · Structural Health Monitoring · doi:10.1177/1475921712461163 · Cited by 36 · see citing works
Self-citationYan, S. T., Li, Y., Zhang, S., et al. (2018) · Sensors · doi:10.3390/s18072106 · Cited by 30 · see citing works
PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage
Huynh, T., Dang, N., & Kim, J. (2018) · Smart Structures and Systems · doi:10.12989/sss.2018.22.1.057 · Cited by 28 · see citing works
Structural Health Monitoring Using Multiple Piezoelectric Sensors and Actuators
Kabeya, K. (1998) · VTechWorks (Virginia Tech) · Cited by 23 · see citing works
Stein, S. C., Liang, C., & Rogers, C. A. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410238 · Cited by 17 · see citing works
Impedance-based structural health monitoring considering temperature effects
Koo, K. Y., Park, S., Lee, J.-J., Yun, C., & Inman, D. J. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.715680 · Cited by 16 · see citing works
Electromechanical impedance-based long-term SHM for jacket-type tidal current power plant structure
Min, J., Yi, J., & Yun, C. (2015) · Smart Structures and Systems · doi:10.12989/sss.2015.15.2.283 · Cited by 13 · see citing works
Cortez, N. E., Filho, J. V., & Baptista, F. G. (2014) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x14538532 · Cited by 12 · see citing works
Self-citationTemperature effects in the analysis of electromechanical impedance by using spectral element method
Xu, G., Xu, B., Xu, C., et al. (2016) · Multidiscipline Modeling in Materials and Structures · doi:10.1108/mmms-03-2015-0015 · Cited by 10 · see citing works
Leakage Detection in Water Pipe Networks Using Electromechanical Impedance (EMI) Based Technique
Pita, J. L., Turra, A. E., & Filho, J. V. (2013) · Acervo Digital da Universidade Estadual Paulista (Universidade Estadual Paulista) · Cited by 2 · see citing works
Cortez, N. E., Filho, J. V., & Baptista, F. G. (2015) · International Workshop on Structural Health Monitoring (IWSHM) · doi:10.12783/shm2015/95 · Cited by 2 · see citing works
Self-citationLizé, E., Hudin, C., Guénard, N., et al. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1712.02832 · Cited by 2 · see citing works
Li, Y., Zhao, H., Liu, S. B., et al. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/392/6/062074 · Cited by 1 · see citing works
Effects of temperature on the electrical impedance of piezoelectric elements
Krishnamurthy, K. C. (1996) · VTechWorks (Virginia Tech) · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [9]Rabelo D.S. Finzi Neto R.M. Steffen V. Jr. Impedance-based structural health monitoring incorporating compensation of temperature variation frequency Proceedings of the 23rd ABCM International Congress of Mechanical Engineering (COBEM 2015) Rio de Janeiro, Brazil 6–11 December 2015
- [12]Thien A.B. Chiamori H.C. Ching J.T. Wait J.R. Park G. Piezoelectric active sensing for damage detection in pipeline structures Proceedings of the 23rd IMAC: Conference and Exposition on Structural Dynamics (IMAC-XXIII) Orlando, FL, USA 31 January–3 February 2005
Cited by
Sorted by citations
Keshmiry, A., Hassani, S., Mousavi, M., & Dackermann, U. (2023) · Buildings · doi:10.3390/buildings13040918 · Cited by 96 · see citing works
- Authors
- Antunes, R. A., Cortez, N. E., Gianesini, B. M., & Vieira Filho, J.
- Affiliations
- Instituto Federal de Educação, Ciência e Tecnologia de Mato Grosso (BR)
- Universidade Federal de Mato Grosso (BR)
- Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira, SP 15385-000, Brazil
- Corresponding author
- Antunes, Rothschild A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-06-22
- Volume
- 19
- Issue
- 12
- Pages
- 2802
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC6631941
- OpenAlex
- W2949956001
- Cited by
- 34
- References
- 38
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 7 · 2020: 3 · 2019: 2
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Americanae (AECID Library) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, other-oa)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior ((Code 001))
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (grant number 310726/2016-6)
- Universidade Estadual Paulista
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Engineering › Mechanical Engineering › Non-Destructive Testing Techniques
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
- Keywords
- structural health monitoring, electromechanical impedance, temperature compensation, steel pipes, pipeline damage detection, piezoelectric sensors, finite element analysis, temperature effects, leak detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review