Modal parameters such as natural frequencies and mode shapes are sensitive indicators of structural damage. However, they are not only sensitive to damage, but also to the environmental conditions such as, humidity, wind and most important, temperature. For civil engineering structures, modal changes produced by environmental conditions can be equivalent or greater than the ones produced by damage. This article proposes a damage detection method which is able to deal with temperature variations. The objective function correlates mode shapes and natural frequencies, and a parallel genetic algorithm handles the inverse problem. The numerical model of the structure assumes that the elasticity modulus of the materials is temperature-dependent. The algorithm updates the temperature and damage parameters together. Therefore, it is possible to distinguish between temperature effects and real damage events. Simulated data of a three-span bridge and experimental one of the I-40 Bridge validate the proposed methodology. Results show that the proposed algorithm is able to assess the experimental damage despite of temperature variations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of environmental and operational variability on structural health monitoring
Sohn, H. (2007) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2006.1935 · Cited by 883
Cited by
Avci, O., Abdeljaber, O., Kiranyaz, S., Hussein, M., Gabbouj, M., & Inman, D. J. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.107077 · Cited by 1,442
Recent progress and future trends on damage identification methods for bridge structures
An, Y., Chatzi, E., Sim, S., Laflamme, S., Blachowski, B., & Ou, J. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2416 · Cited by 338
A review of damage detection methods for wind turbine blades
Li, D., Ho, S.-C. M., Song, G., Ren, L., & Li, H. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/3/033001 · Cited by 244
“One of the main obstacles for deploying a damage detection system for inservice blades is the environmental and operational variation of turbine blades, which may include nonuniform thermal gradients or changing boundary conditions (Meruane and Heylen 2012).”
BackgroundReynders, E., Wursten, G., & De Roeck, G. (2014) · Structural Health Monitoring · doi:10.1177/1475921713502836 · Cited by 237
Structural health monitoring research under varying temperature condition: a review
Han, Q., Ma, Q., Xu, J., & Liu, M. (2021) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-020-00444-x · Cited by 190
Luo, J., Huang, M., & Lei, Y. (2022) · Buildings · doi:10.3390/buildings12081209 · Cited by 90
On the use of mode shape curvatures for damage localization under varying environmental conditions
Shokrani, Y., Dertimanis, V. K., Chatzi, E. N., & N. Savoia, M. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2132 · Cited by 76
Kostić, B., & Gül, M. (2017) · Journal of Bridge Engineering · doi:10.1061/(asce)be.1943-5592.0001085 · Cited by 74
Ensemble classification method for structural damage assessment under varying temperature
Fallahian, M., Khoshnoudian, F., & Meruane, V. (2018) · Structural Health Monitoring · doi:10.1177/1475921717717311 · Cited by 60
Self-citation
Metadata
- Authors
- Meruane, V, & Heylen, W.
- Venue
- Structural Health Monitoring
- Publisher
- SAGE Publications
- Published
- 2011-09-12
- Volume
- 11
- Issue
- 3
- Pages
- 345-357
- ISSN
- 1475-9217 (ISSN-L)
- 1741-3168
- OpenAlex
- W2051837837
- Cited by
- 75
- References
- 1
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.