Compressed sensing techniques for detecting damage in structures
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
One of the principal challenges facing the structural health monitoring community is taking large, heterogeneous sets of data collected from sensors, and extracting information that allows the estimation of the damage condition of a structure. Another important challenge is to collect relevant data from a structure in a manner that is cost-effective, and respects the size, weight, cost, energy consumption and bandwidth limitations placed on the system. In this work, we established the suitability of compressed sensing to address both challenges. A digital version of a compressed sensor is implemented on-board a microcontroller similar to those used in embedded SHM sensor nodes. The sensor node is tested in a surrogate SHM application using acceleration measurements. Currently, the prototype compressed sensor is capable of collecting compressed coefficients from measurements and sending them to an off-board processor for signal reconstruction using ℓ 1 norm minimization. A compressed version of the matched filter known as the smashed filter has also been implemented on-board the sensor node, and its suitability for detecting structural damage will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 2×
“0.(9) Equation (3) implies that it is possible to reconstruct a sparse signal x using far fewer measurements than elements in x.”
BackgroundOn the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326 · cited 1×
“The result is the emergence of the ‘leakage’ phenomenon commonly encountered in Fourier analysis.(21) The leakage effectively decreases the sparsity of a measured signal in the discrete Fourier basis.”
BackgroundAnalog-to-Information Conversion via Random Demodulation
Kirolos, S., Laska, J., Wakin, M., Duarte, M., Baron, D., Ragheb, T., Massoud, Y., & Baraniuk, R. (2006) · 2006 IEEE Dallas/CAS Workshop on Design, Applications, Integration and Software · doi:10.1109/dcas.2006.321036 · Cited by 393 · cited 1×
“, Los Alamos National Laboratory, PO Box 1663 MS T001, Los Alamos, NM 87544, LA-UR 12-01484 reduced energy consumption for data collection, storage and transmission [3], [4].”
Background
Cited by
Hou, R., & Xia, Y. (2021) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2020.115741 · Cited by 674
The State of the Art of Data Science and Engineering in Structural Health Monitoring
Bao, Y., Chen, Z., Wei, S., Xu, Y., Tang, Z., & Li, H. (2019) · Engineering · doi:10.1016/j.eng.2018.11.027 · Cited by 483
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Capineri, L., & Bulletti, A. (2021) · doi:10.20944/preprints202103.0347.v2 · Cited by 131
Zhang, C. D., & Xu, Y. L. (2016) · Structural Control and Health Monitoring · doi:10.1002/stc.1785 · Cited by 106
“[11,12], compressed sensing techniques were used in data communication among wireless sensor nodes, where l1-norm regularization was employed to reconstruct time series measurements of acceleration.”
Method
Metadata
- Authors
- Mascareñas, D., Cattaneo, A., Theiler, J., & Farrar, C.
- Venue
- Structural Health Monitoring
- Publisher
- SAGE Publications
- Published
- 2013-06-17
- Volume
- 12
- Issue
- 4
- Pages
- 325-338
- ISSN
- 1475-9217 (ISSN-L)
- 1741-3168
- OpenAlex
- W1965624190
- Cited by
- 78
- References
- 3
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.