Abstract

This study examined human subjective and pupil responses to small, high-luminance light sources seen against low-luminance backgrounds. Subjective judgements of glare using a seven-point rating scale and the change in pupil diameters following exposure to glare of 47 subjects were measured during evaluation of 36 conditions comprising three glare source luminances (20,000; 205,000; 750,000 cd/m 2 ), two source positions (0°, 10°), two source sizes (10 −5 , 10 −4 sr) and three background luminances (0.03; 0.3; 1 cd/m 2 ). Data analysis suggests that the relative pupil size is correlated with subjective responses to discomfort glare to some extent (r = 0.659). Analysis of variance of relative pupil size measurements demonstrates a significant main effect of the background luminance suggesting that when the background luminance decreases, the relative pupil size increases. Relative pupil size shows the same trend as the relative change in illuminance at the eyes and the discomfort glare perception.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1477153518772000

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 44

  1. 10.1080/15502724.2014.861279 · doi:10.1080/15502724.2014.861279
  2. 10.1080/15502724.2018.1434415 · doi:10.1080/15502724.2018.1434415
  3. 10.1889/JSID19.12.888 · doi:10.1889/jsid19.12.888
  4. Olson PL. Research on discomfort glare at UMTRI: Symposium Proceedings , Orlando, FL, 24–25 October, 1991: pp. 165–171. New York: The Lighting Research Institute.
  5. 10.1007/978-1-4020-8602-1 · DOI
  6. Reis HT, 2000, Handbook of Research Methods in Social and Personality Psychology
  7. 10.1582/LEUKOS.2009.06.01003 · DOI
  8. Luckiesh M, 1949, Illuminating Engineering, 44, 650
  9. 10.1080/00994480.2003.10748406 · doi:10.1080/00994480.2003.10748406
  10. Clarke KC, Boyce PR, Beckstead JW. Factors influencing the stability of glare assessments: Proceedings of the Conference of the Illuminating Engineering Society of North America , Montreal, Canada, 11–15 August, 1991: pp. 36–66.
  11. Maruyama G, 2014, Research Methods in Social Relations
  12. 10.1007/978-1-4020-2666-9 · DOI
  13. Poulton EC, 1989, Bias in Quantifying Judgements
  14. Fischer D. Discomfort glare in interiors: Symposium Proceedings , Orlando, FL, 24–25 October, 1991: pp. 1–32. New York: The Lighting Research Institute.
  15. 10.1037/0033-295X.101.2.343 · DOI · Paper page
  16. 10.1080/00994480.1977.10748959 · doi:10.1080/00994480.1977.10748959
  17. 10.1201/b16707 · DOI · Paper page
  18. 10.1364/JOSA.46.000649 · DOI
  19. 10.1167/iovs.14-15963 · doi:10.1167/iovs.14-15963
  20. 10.1080/00994480.1994.10748079 · DOI
  21. 10.1167/iovs.10-6699 · DOI
  22. Lin Y, Liu Y, Sun Y, Qiu J. A pilot study of the physiological mechanism of the glare caused by LED based on the fluctuations of the electro-oculogram: The CIE Proceedings x039:2014. Lighting Quality and Energy Efficiency, Kuala Lumpur, Malaysia, 2014.
  23. 10.1191/1365782806lrt160oa · doi:10.1191/1365782806lrt160oa
  24. Putnam R, 1951, Illuminating Engineering, 46, 505
  25. Putnam R, 1957, Illuminating Engineering, 52, 226
  26. 10.1177/1477153508094048 · doi:10.1177/1477153508094048
  27. 10.1191/1477153503li083oa · doi:10.1191/1477153503li083oa
  28. DiLaura D, Houser K, Mistrick R, Steffy G. The Lighting Handbook: Reference and Application, 10th Edition. New York: Illuminating Engineering Society of North America, 2011, pp. 1328–1328.
  29. 10.1016/0042-6989(77)90129-8 · DOI
  30. Tyukhova Y. Discomfort glare from small, high luminance light sources in outdoor nighttime environments. PhD thesis, University of Nebraska–Lincoln, USA, 2015.
  31. 10.1080/00994480.1980.10748591 · doi:10.1080/00994480.1980.10748591
  32. 10.1177/096032719202400105 · DOI
  33. 10.4324/9781315744131 · DOI · Paper page
  34. Howell DC, 2011, Fundamental Statistics for the Behavioral Sciences
  35. Rea RL, 2013, Neuro-Ophthalmology
  36. Benz C. Untersuchungen Uber Die Psychologische Blendung Bei Umfeldleuchtdichten Im Mesopischen Bereich (Investigation of Discomfort Glare Under Mesopic Ambient Luminance Levels). PhD thesis, Technischen Hochschule Karlsruhe, Germany, 1966.
  37. Zhu X, 2013, Light and Engineering, 21, 51
  38. Rosenbaum DA, 1991, Human Motor Control
  39. 10.1097/00006324-195707000-00004 · doi:10.1097/00006324-195707000-00004
  40. 10.1002/wcs.1323 · DOI · Paper page
  41. 10.1016/j.cub.2007.11.034 · DOI · Paper page
  42. 10.1167/12.10.12 · DOI · Paper page
  43. 10.1177/1477153509102344 · doi:10.1177/1477153509102344
  44. 10.1177/096032719302500106 · doi:10.1177/096032719302500106

Cited by

See all 29

Metadata

Authors
Tyukhova, Y., & Waters, C.
Venue
Lighting Research & Technology
Published
2018-06-06
Volume
51
Issue
4
Pages
592-611
ISSN
  • 1477-1535
  • 1477-0938
Cited by
29
References
0
Language
en
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Funders
Musco Sports Lighting

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subjective and pupil responses to discomfort glare from small, high-luminance light sources. https://app.cochat.ai/papers/10.1177/1477153518772000
The paper
Tyukhova, Y., & Waters, C. (2019). Subjective and pupil responses to discomfort glare from small, high-luminance light sources. Lighting Research & Technology. https://doi.org/10.1177/1477153518772000

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.