The impact of flash glucose monitoring on glycated hemoglobin in type 2 diabetes managed with basal insulin in Canada: A retrospective real-world chart review study
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: The real-world effect of intermittently scanned continuous glucose monitoring on glucose control in type 2 diabetes treated with basal insulin is uncertain. This retrospective real-world study aimed to evaluate change in glycated hemoglobin (HbA1c) amongst adults with type 2 diabetes managed with basal insulin starting flash glucose monitoring. Methods: Medical records were reviewed for adults with type 2 diabetes treated with basal insulin for ⩾1 year and using FreeStyle Libre TM Flash Glucose Monitoring for ⩾3 months. Prior to device use an HbA1c 8.0%–12.0% was recorded and a further HbA1c result was recorded 3–6 months (90–194 days) after starting device use. Results: Medical records ( n = 91) analyzed from six Canadian diabetes centers showed HbA1c significantly decreased by 0.8% ± 1.1 (mean ± SD, [ p < 0.0001]) from mean baseline HbA1c 8.9% ± 0.9 to 8.1% ± 1.0 at 3–6 months after initiating flash glucose monitoring. HbA1c improvement was not independently associated with age, BMI, insulin use duration, or sex. Conclusion: This Canadian real-world retrospective study showed significantly reduced HbA1c following initiation of flash glucose monitoring technology to further support management of type 2 diabetes treated with basal insulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
Evans, M., Welsh, Z., Ells, S., & Seibold, A. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00720-0 · Cited by 185
Kröger, J., Fasching, P., & Hanaire, H. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00741-9 · Cited by 90
Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84
MILLER, E., BRANDNER, L., & WRIGHT, E. (2020) · Diabetes · doi:10.2337/db20-84-lb · Cited by 23
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Aronson, R., Brown, R. E., Chu, L., Bajaj, H. S., Khandwala, H., Abitbol, A., Malakieh, N., & Goldenberg, R. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14949 · Cited by 118
Self-citationContinuous glucose monitoring for the routine care of type 2 diabetes mellitus
Ajjan, R. A., Battelino, T., Cos, X., Del Prato, S., Philips, J.-C., Meyer, L., Seufert, J., & Seidu, S. (2024) · Nature Reviews Endocrinology · doi:10.1038/s41574-024-00973-1 · Cited by 117
“These data are consistent with results of retrospective studies demonstrating significant reductions in HbA 1c in people with T2DM on basal insulin therapy 59,60 .”
Metadata
- Authors
- Elliott, T., Beca, S., Beharry, R., Tsoukas, M. A., Zarruk, A., & Abitbol, A.
- Venue
- Diabetes and Vascular Disease Research
- Publisher
- SAGE Publications
- Published
- 2021-07
- Volume
- 18
- Issue
- 4
- Pages
- 14791641211021374-14791641211021374
- ISSN
- 1479-1641 (ISSN-L)
- 1752-8984
- OpenAlex
- W3184973978
- Cited by
- 49
- References
- 6
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The impact of flash glucose monitoring on glycated hemoglobin in type 2 diabetes managed with basal insulin in Canada: A retrospective real-world chart review study. https://app.cochat.ai/papers/10.1177/14791641211021374
- The paper
- Elliott, T., Beca, S., Beharry, R., Tsoukas, M. A., Zarruk, A., & Abitbol, A. (2021). The impact of flash glucose monitoring on glycated hemoglobin in type 2 diabetes managed with basal insulin in Canada: A retrospective real-world chart review study. Diabetes and Vascular Disease Research. https://doi.org/10.1177/14791641211021374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.