The Impact of Flash Glucose Monitoring on Glycaemic Control as Measured by HbA1c: A Meta-analysis of Clinical Trials and Real-World Observational Studies
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Glycated haemoglobin A1c (HbA1c) is the established standard measurement for assessment of glycaemic control in people with diabetes. Here we report on a meta-analysis of real-world observational studies on the impact of flash continuous glucose monitoring on glycaemic control as measured by HbA1c. A total of 271 studies were identified in our search, of which 29 contained data reporting changes in HbA1c over periods from 1 to 24 months that could be used in a statistical analysis. Our meta-analysis focuses on observed change in HbA1c at either 2, 3 or 4 months, in adult or paediatric subjects, as well as a longitudinal analysis up to 12 months in adult subjects. These data were drawn from 25 of the studies identified in our initial search. These reported HbA1c data up to 12 months in a total of 1723 participants with type 1 diabetes (T1D) or type 2 diabetes (T2D) using the FreeStyle Libre ® flash glucose monitoring system. Overall mean change in laboratory HbA1c across study subjects at 2–4 months was − 0.55% (95% CI − 0.70, − 0.39). Amongst the 1023 adults, mean change in HbA1c was − 0.56% (95% CI − 0.76, − 0.36); for the 447 children and adolescents, mean change in HbA1c was − 0.54% (95% CI − 0.84, − 0.23). Based on regression analysis, the degree of change in HbA1c correlated with the initial HbA1c of the study population. A longitudinal analysis in adult subjects ( n = 1276) shows that HbA1c fell within the first 2 months and changes were sustained up to 12 months. No significant differences were detected between T1D and T2D. The meta-analysis reported here confirms that starting the FreeStyle Libre system as part of diabetes care results in a significant and sustained reduction in HbA1c for adults and children with T1D and for adults with T2D. Abbott Diabetes Care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“Cochran’s heterogeneity statistic (Q) and the I(2) statistic were calculated [40].”
Method(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2014) · International Journal of Surgery · doi:10.1016/j.ijsu.2014.07.013 · Cited by 9,909
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Gupta, A., & Uribarri, J. (2016) · Hormone Research in Paediatrics · doi:10.1159/000444053 · Cited by 4,006
Research works printed but not linked: 12
- Gibb FW, Stimson RH, Zammitt NN, et al. Flash glucose monitoring is associated with improved glycaemic control and quality of life in people with type 1 diabetes: a large ‘real-world’ assessment. Diabetologia. 2018;16(S1):S391.
- Xatzipsalti M, Mentesidou L, Kourti A, et al. Flash glucose monitoring system improves glycemic control. Pediatr Diabetes. 2017;18(Suppl. 25):78.
- Helm N, De ML, Forsman S, et al. Flash glucose monitoring improves perception and frequency of glucose monitoring leading to improved glucose control. Pediatr Diabetes. 2016;17:115.
- Wijnands A, Gys I, Bevilacqua E, et al. The FreeStyle flash glucose monitoring system has limited effect on the metabolic control of children and adolescents with type 1 diabetes mellitus. Pediatr Diabetes. 2017;18(Suppl. 25):38.
- Walton-Betancourth S, Amin R. A clinic-based study of the impact of flash glucose sensing technology on glycaemic control and self-monitoring of blood glucose in children and young people with type 1 diabetes. Pediatr Diabetes. 2017;18(Suppl. 25):47.
- Bacon S, O’Dwyer B, Chambers C, et al. The performance and technical usability of a flash glucometer monitoring system. Irish J Med Sci. 2017;186(9):S357.
- Karlsson E. HbA1c after one year of use of flash glucose monitoring in patients with type 1 diabetes. Thesis, University of Orebero, Sweden.
- Abdalaziz A, Lan K, Bilous M, et al. Flash glucose monitoring (FGM) in people with type 1 diabetes: single centre-real-world experience. Diabetes Med. 2018;35(S1):168.
- Löndahl M, Filipsson K, Lindholm E, et al. Effect of flash glucose monitoring on metabolic control and self-esteem treatment satisfaction in people with T1DM. Diabetes Technol Ther. 2017;19(S1):A-81.
- Holcombe A, Karunakaran V, Streeting J, et al. Trial of FreeStyle Libre in a local service: impact on diabetes outcomes. Diabetes Med. 2017;34(S1):160.
- Tirelli E, Frontino G, Favalli V, et al. Flash glucose monitoring in noncompliant children and adolescents with type 1 diabetes. Diabetes Technol Ther. 2017;19(S1):A-83.
- Hey C, Alkharaiji M, Anyanwagu U, et al. Impact of FreeStyle Libre on glycaemic control, frequency of glucose monitoring and treatment satisfaction. Diabetes Med. 2018;35(Supplement 1):195.
Cited by
Davies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetes Care · doi:10.2337/dci22-0034 · Cited by 2,104
“0 mmol/L [70–180 mg/dL]), fewer hyperglycemic and hypoglycemic episodes, and improvements in diabetes distress (336,337).”
BackgroundDavies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetologia · doi:10.1007/s00125-022-05787-2 · Cited by 1,048
“0 mmol/l [70–180 mg/dl]), fewer hyperglycaemic and hypoglycaemic episodes and improvements in diabetes distress [336, 337].”
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Moser, O., Riddell, M. C., Eckstein, M. L., Adolfsson, P., Rabasa-Lhoret, R., van den Boom, L., Gillard, P., Nørgaard, K., Oliver, N. S., Zaharieva, D. P., et al. (2020) · Diabetologia · doi:10.1007/s00125-020-05263-9 · Cited by 214
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
Metadata
- Authors
- Evans, M., Welsh, Z., Ells, S., & Seibold, A.
- Affiliations
- University of Cambridge (GB)
- Abbott (United Kingdom) (GB)
- Abbott (Germany) (DE)
- Corresponding author
- Evans, Mark
- Venue
- Diabetes Therapy
- Published
- 2019-10-31
- Volume
- 11
- Issue
- 1
- Pages
- 83-95
- ISSN
- 1869-6953 (ISSN-L)
- 1869-6961
- PMC
- PMC6965602
- OpenAlex
- W2985334076
- Semantic Scholar
- fa2c3b9618ae1927bee327bcb58209361235b57b
- Cited by
- 185
- References
- 36
- Citations by year
- 2026: 15 · 2025: 20 · 2024: 23 · 2023: 26 · 2022: 40 · 2021: 33 · 2020: 28
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- creativecommons.org/licenses/by-nc/4.0 (tdm)
- creativecommons.org/licenses/by-nc/4.0 (vor)
- Locations
- Diabetes Therapy (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by-nc)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo
- Funders
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- flash glucose monitoring, continuous glucose monitoring, HbA1c, glycemic control, type 1 diabetes, type 2 diabetes, FreeStyle Libre, pediatric diabetes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Impact of Flash Glucose Monitoring on Glycaemic Control as Measured by HbA1c: A Meta-analysis of Clinical Trials and Real-World Observational Studies. https://app.cochat.ai/papers/10.1007/s13300-019-00720-0
- The paper
- Evans, M., Welsh, Z., Ells, S., & Seibold, A. (2020). The Impact of Flash Glucose Monitoring on Glycaemic Control as Measured by HbA1c: A Meta-analysis of Clinical Trials and Real-World Observational Studies. Diabetes Therapy. https://doi.org/10.1007/s13300-019-00720-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.