The DOI matches its Crossref record.
The Effect of Irreversible Electroporation on Blood Vessels
Abstract
We present a pilot study on the long term effects of irreversible electroporation (IRE) on a large blood vessel. The study was motivated by the anticipated use of IRE for treatment of cancer tumors abutting large blood vessels. A sequence of 10 direct current IRE pulses of 3800 V/cm, 100μs each, at a frequency of 10 pulses per second, were applied directly to the carotid artery in six rats. Measuring tissue conductivity during the procedure showed, as predicted, an increase in conductivity during the application of the pulse, which suggests that this measurement can be used to control the application of IRE. All the animals survived the procedure and showed no side effects. Histology performed 28 days after the procedure showed that the connective matrix of the blood vessels remained intact and the number of vascular smooth muscle cells (VSMC) in the arterial wall decreased with no evidence of aneurysm, thrombus formation or necrosis. Average VSMC density was significantly lower following IRE ablation compared with control (24 ± 11 vs. 139 ± 14, P<0.001), with no apparent damage to extra cellular matrix components and structure. In addition to the relevance of this study to treatment of cancer near large blood vessels these findings tentatively suggest that IRE has possible applications to treatment of pathological processes in which it is desired to reduce the proliferation of VSMC population, such as restenosis and for attenuating atherosclerotic processes in clinical important locations such as coronary, carotid and renal arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sano, M. B., Neal, R. E., Garcia, P. A., Gerber, D., Robertson, J., & Davalos, R. V. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-83 · Cited by 117
Irreversible electroporation (NanoKnife) in cancer treatment
Jourabchi, N., Beroukhim, K., Tafti, B. A., Kee, S. T., & Lee, E. W. (2014) · Gastrointestinal Intervention · doi:10.1016/j.gii.2014.02.002 · Cited by 99
López-Alonso, B., Hernáez, A., Sarnago, H., Naval, A., Güemes, A., Junquera, C., Burdío, J. M., Castiella, T., Monleón, E., Gracia-Llanes, J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-39433-6 · Cited by 48
Metadata
- Authors
- Maor, E., Ivorra, A., Leor, J., & Rubinsky, B.
- Venue
- Technology in Cancer Research & Treatment
- Publisher
- SAGE Publications
- Published
- 2007-08
- Volume
- 6
- Issue
- 4
- Pages
- 307-312
- ISSN
- 1533-0338 (ISSN-L)
- 1533-0346
- OpenAlex
- W2089819212
- Cited by
- 370
- References
- 0
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Irreversible Electroporation on Blood Vessels. https://app.cochat.ai/papers/10.1177/153303460700600407
- The paper
- Maor, E., Ivorra, A., Leor, J., & Rubinsky, B. (2007). The Effect of Irreversible Electroporation on Blood Vessels. Technology in Cancer Research & Treatment. https://doi.org/10.1177/153303460700600407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.