The Tumoricidal Effect of Sonodynamic Therapy (SDT) on S-180 Sarcoma in Mice
Open accessThe DOI matches its Crossref record.
Abstract
There are increasing data showing that sonodynamic therapy (SDT), which refers to a synergistic effect of drugs and ultrasound, is a promising new modality for cancer treatment. However, few clinical data on SDT have been published. One reason is the lack of suitable drugs for clinical SDT use. Recently a new sonosensitizing agent has been developed by SonneMed, LLC, referred to as SF1. In this study the effect of SDT with SF1 on S-180 sarcoma in mice was examined. The tumor bearing mice were allocated to the following groups: (1) sham-treatment (control, C); (2) ultrasound treatment (only ultrasound treatment, 1.2 mW/cm 2 , without SF1, U); (3) SF1 treatment (SF1 20 mg/kg intraperitoneal [ip] without ultrasound treatment, S); and (4) SF1 + ultrasound treatment (SU). Following treatment, tumor volume was monitored. Tumor growth inhibition was seen only in group SU, and with increasing ultrasound intensity, the inhibitory effect was enhanced. Tumor growth inhibition was also visible even when covered by a barrier of bone. Pathological slices showed coagulated necrosis or metamorphic tissue with inflammatory reaction in the tumor taken from 2 to 36 hours after SDT. These data revealed that SDT with SF1 did inhibit growth of mouse S-180 sarcoma and the inhibitory effect was sound intensity dependent. SDT also induced some inflammation while it destroyed the tumor, indicative of a “vaccine” effect. SF1 shows great promise for clinical use in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Qian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
Nanoparticle-assisted ultrasound: A special focus on sonodynamic therapy against cancer
Canavese, G., Ancona, A., Racca, L., Canta, M., Dumontel, B., Barbaresco, F., Limongi, T., & Cauda, V. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.01.060 · Cited by 457
Sonodynamic Therapy: Concept, Mechanism and Application to Cancer Treatment
McHale, A. P., Callan, J. F., Nomikou, N., Fowley, C., & Callan, B. (2016) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-319-22536-4_22 · Cited by 343
Gong, Z., & Dai, Z. (2021) · Advanced Science · doi:10.1002/advs.202002178 · Cited by 320
Li, D., Yang, Y., Li, D., Pan, J., Chu, C., & Liu, G. (2021) · Small · doi:10.1002/smll.202101976 · Cited by 255
Zheng, Y., Ye, J., Li, Z., Chen, H., & Gao, Y. (2021) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2020.12.016 · Cited by 173
Sonodynamic Therapy: Advances and Challenges in Clinical Translation
Lafond, M., Yoshizawa, S., & Umemura, S. (2019) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14733 · Cited by 164
Sonodynamic and Photodynamic Therapy in Advanced Breast Carcinoma: A Report of 3 Cases
Wang, X., Zhang, W., Xu, Z., Luo, Y., Mitchell, D., & Moss, R. W. (2009) · Integrative Cancer Therapies · doi:10.1177/1534735409343693 · Cited by 134
Self-citation
Metadata
- Authors
- Wang, X., Lewis, T. J., & Mitchell, D.
- Venue
- Integrative Cancer Therapies
- Publisher
- SAGE Publications
- Published
- 2008-05-27
- Volume
- 7
- Issue
- 2
- Pages
- 96-102
- ISSN
- 1534-7354 (ISSN-L)
- 1552-695X
- OpenAlex
- W2017047556
- Cited by
- 51
- References
- 0
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.