Effects of Key Size and Spacing on the Completion Time and Accuracy of Input Tasks on Soft Keypads Using Trackball and Touch Input
The DOI matches its Crossref record.
Abstract
Simulated keyboards on touch screens are becoming the norm for data entry on mobile and kiosk systems. Since onscreen keyboards compete with other user interface elements for limited screen space, it is essential that soft keyboard designs are optimally laid out. This paper describes an experiment in which the performance and accuracy of data input on soft keyboards with square keys of two different widths (10 and 15 mm) and two inter-key gap distances (1.5 and 4.5 mm) were evaluated. Three methods of input were studied: finger, stylus, and trackball. Entry times were the shortest and most accurate for stylus touch, although trackball input was the most accurate for the smallest key size. The spacing between keys did not exhibit a significant effect regardless of key size and input method. A key size of 15 mm appears to be sufficiently large to provide acceptable accuracy for touch input, although a key size of 10 mm was equally acceptable for trackball input.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The influence of age in usability testing
Sonderegger, A., Schmutz, S., & Sauer, J. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.06.012 · Cited by 152
“…amount of research has addressed issues such as key size and spacing in touchscreen design using typical user populations like younger adults (e.g. Schedlbauer, 2007; Scott & Conzola, 1997; Colle & Hiszem, 2004), comparatively little is known about the usage of touchscreen devices by older adult…”
BackgroundSesto, M. E., Irwin, C. B., Chen, K. B., Chourasia, A. O., & Wiegmann, D. A. (2012) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720811433831 · Cited by 73
“…use of touch screen interfaces, researchers have studied how interface design (including button size and spacing) affects user performance (e.g., accuracy and time to complete a task; Colle & Hiszem, 2004; Jin, Plocher, & Kiff, 2007; Martin, 1988; Schedlbauer, 2007; Scott & Conzola, 1997).”
BackgroundInvestigation of Icon Design and Touchable Area for Effective Smart Phone Controls
Im, Y., Kim, T., & Jung, E. S. (2015) · Human Factors and Ergonomics in Manufacturing & Service Industries · doi:10.1002/hfm.20593 · Cited by 26
“Moreover, their experimental tasks consisted of entering text or numeric sequences (Schedlbauer, 2007) and inputting simple touch keys (Karlson et al., 2005; Park & Han, 2010b).”
BackgroundHuang, Y.-C., & Wu, F.-G. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2015.08.002 · Cited by 12
Metadata
- Authors
- Schedlbauer, M.
- Venue
- Proceedings of the Human Factors and Ergonomics Society Annual Meeting
- Publisher
- SAGE Publications
- Published
- 2007-10
- Volume
- 51
- Issue
- 5
- Pages
- 429-433
- ISSN
- 0163-5182 (ISSN-L)
- 1071-1813
- 2169-5067
- OpenAlex
- W2025998677
- Cited by
- 34
- References
- 0
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Key Size and Spacing on the Completion Time and Accuracy of Input Tasks on Soft Keypads Using Trackball and Touch Input. https://app.cochat.ai/papers/10.1177/154193120705100501
- The paper
- Schedlbauer, M. (2007). Effects of Key Size and Spacing on the Completion Time and Accuracy of Input Tasks on Soft Keypads Using Trackball and Touch Input. Proceedings of the Human Factors and Ergonomics Society Annual Meeting. https://doi.org/10.1177/154193120705100501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.