Oxygen Inhibition in Dental Resins
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Oxygen inhibits free radical polymerization and yields polymers with uncured surfaces. This is a concern when thin layers of resin are being polymerized, or in circumstances where conventional means of eliminating inhibition are inappropriate. In this study, we tested the hypothesis that viscosity, filler content, and polymerization temperature modify oxygen diffusion in the resin or the reactivity of radical species, and affect the degree of conversion near the surface. Confocal Raman micro-spectroscopy was used to measure monomer conversion from the surface to the bulk of cured resins. Increased viscosity was shown to limit oxygen diffusion and increase conversion near the surface, without necessarily modifying the depth of inhibition. The filler material was shown to increase, simultaneously, oxygen diffusivity and the viscosity of the resin, which have opposite effects on conversion. Polymerization at a temperature above ~ 110°C was shown to eliminate oxygen inhibition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long, D., & Lequeux, F. (2001) · The European Physical Journal E · doi:10.1007/s101890170120 · Cited by 348 · cited 2×
“…past this point, the polymer/filler interactions which are responsible for the increase in viscosity [and subsequently reduced oxygen transport (Long and Lequeux, 2001; Sereda et al., 2003)] become more pronounced than those phenomena which facilitate oxygen transport, and inhibition is…”
BackgroundModeling and Measuring the Effect of Refraction on the Depth Resolution of Confocal Raman Microscopy
Everall, N. J. (2000) · Applied Spectroscopy · doi:10.1366/0003702001950382 · Cited by 339 · cited 2×
“Past studies have concluded that the most accurate way of depth-profiling a large sample would be to section the latter vertically and then scan the microscope laterally along the cut (Everall, 2000a,b).”
BackgroundPolymer/Silica Composite Films as Luminescent Oxygen Sensors
Lu, X., Manners, I., & Winnik, M. A. (2001) · Macromolecules · doi:10.1021/ma001454j · Cited by 97 · cited 2×
“Filler particles may act as obstacles to oxygen diffusion (Odrobina et al., 2001), may adsorb oxygen onto their surface, but may also allow for diffusion along their surface, thereby providing new pathways for oxygen diffusion, depending on the specific polymer/filler interactions (Lu et al., 2001).”
BackgroundSorption and partial molar volume of gases in poly (dimethyl siloxane)
Kamiya, Y., Naito, Y., Hirose, T., & Mizoguchi, K. (1990) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.1990.090280808 · Cited by 61 · cited 2×
“particles, may also provoke a decrease of conversion at the composite/atmosphere interface, in accordance with Henry's law (Kamiya et al., 1990).”
MethodHajatdoost, S., & Yarwood, J. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905961 · Cited by 58 · cited 2×
“Depth resolution with this arrangement was found, by a standard method, to be 1.16 m in air ( Hajatdoost and Yarwood, 1996 ).”
MethodInfluentialEffect of Soft Filler Particles on Polymer Diffusion in Poly(butyl methacrylate) Latex Films
Odrobina, E., Feng, J., Pham, H. H., & Winnik, M. A. (2001) · Macromolecules · doi:10.1021/ma002052e · Cited by 22 · cited 2×
“Filler particles may act as obstacles to oxygen diffusion ( Odrobina et al., 2001 ), may adsorb oxygen onto their surface, but may also allow for diffusion along their surface, thereby providing new pathways for oxygen diffusion, depending on the specific polymer/filler interactions (Lu et al., 2001).”
Background
Cited by
Systematic review of the chemical composition of contemporary dental adhesives
Van Landuyt, K. L., Snauwaert, J., De Munck, J., Peumans, M., Yoshida, Y., Poitevin, A., Coutinho, E., Suzuki, K., Lambrechts, P., & Van Meerbeek, B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.044 · Cited by 1,397
Strategies to Reduce Oxygen Inhibition in Photoinduced Polymerization
Ligon, S. C., Husár, B., Wutzel, H., Holman, R., & Liska, R. (2014) · Chemical Reviews · doi:10.1021/cr3005197 · Cited by 721
Corrigan, N., Rosli, D., Jones, J. W. J., Xu, J., & Boyer, C. (2016) · Macromolecules · doi:10.1021/acs.macromol.6b01306 · Cited by 245
PET-RAFT polymerisation: towards green and precision polymer manufacturing
Phommalysack-Lovan, J., Chu, Y., Boyer, C., & Xu, J. (2018) · Chemical Communications · doi:10.1039/c8cc02783h · Cited by 245
The role of HEMA in one-step self-etch adhesives
Van Landuyt, K. L., Snauwaert, J., Peumans, M., De Munck, J., Lambrechts, P., & Van Meerbeek, B. (2008) · Dental Materials · doi:10.1016/j.dental.2008.02.018 · Cited by 232
“The latter are not only smaller, but can also only be found at the transition between adhesive layer and lining composite, which corresponds to the oxygen-inhibition layer, a zone with uncured monomers [23,27].”
BackgroundZhang, W., Bao, B., Jiang, F., Zhang, Y., Zhou, R., Lu, Y., Lin, S., Lin, Q., Jiang, X., & Zhu, L. (2021) · Advanced Materials · doi:10.1002/adma.202105667 · Cited by 227
Ferracane, J. L., Hilton, T. J., Stansbury, J. W., Watts, D. C., Silikas, N., Ilie, N., Heintze, S., Cadenaro, M., & Hickel, R. (2017) · Dental Materials · doi:10.1016/j.dental.2017.08.188 · Cited by 179
“The use of confocal Raman depth profiling capabilities has been used to probe oxygen-inhibited surface layers [54] as well as a source of depth-dependent data on both polymer composition and conversion in dental adhesives.”
Thiol-ene-methacrylate composites as dental restorative materials
Boulden, J. E., Cramer, N. B., Schreck, K. M., Couch, C. L., Bracho-Troconis, C., Stansbury, J. W., & Bowman, C. N. (2011) · Dental Materials · doi:10.1016/j.dental.2010.11.001 · Cited by 93
Metadata
- Authors
- Gauthier, M. A., Stangel, I., Ellis, T. H., & Zhu, X. X.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2005-08
- Volume
- 84
- Issue
- 8
- Pages
- 725-729
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2011475935
- Cited by
- 180
- References
- 6
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.