The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Kinematic Robot-Based Evaluation Scales and Clinical Counterparts to Measure Upper Limb Motor Performance in Patients With Chronic Stroke
Open accessAbstract
Background. Human-administered clinical scales are the accepted standard for quantifying motor performance of stroke subjects. Although they are widely accepted, these measurement tools are limited by interrater and intrarater reliability and are time-consuming to apply. In contrast, robot-based measures are highly repeatable, have high resolution, and could potentially reduce assessment time. Although robotic and other objective metrics have proliferated in the literature, they are not as well established as clinical scales and their relationship to clinical scales is mostly unknown. Objective. To test the performance of linear regression models to estimate clinical scores for the upper extremity from systematic robot-based metrics. Methods. Twenty kinematic and kinetic metrics were derived from movement data recorded with the shoulder-and-elbow InMotion2 robot (Interactive Motion Technologies, Inc), a commercial version of the MIT-Manus. Kinematic metrics were aggregated into macro-metrics and micro-metrics and collected from 111 chronic stroke subjects. Multiple linear regression models were developed to calculate Fugl-Meyer Assessment, Motor Status Score, Motor Power, and Modified Ashworth Scale from these robot-based metrics. Results. Best performance—complexity trade-off was achieved by the Motor Status Score model with 8 kinematic macro-metrics ( R = .71 for training; R = .72 for validation). Models including kinematic micro-metrics did not achieve significantly higher performance. Performances of the Modified Ashworth Scale models were consistently low ( R = .35-.42 for training; R = .08-.17 for validation). Conclusions. The authors identified a set of kinetic and kinematic macro-metrics that may be used for fast outcome evaluations. These metrics represent a first step toward the development of unified, automated measures of therapy outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
Introduction to Linear Regression Analysis.
Assuncao, R., Sampson, P. D., Montgomery, D. C., & Peck, E. A. (1993) · Journal of the American Statistical Association · doi:10.2307/2290746 · Cited by 5,388
Gladstone, D. J., Danells, C. J., & Black, S. E. (2002) · Neurorehabilitation and Neural Repair · doi:10.1177/154596802401105171 · Cited by 2,032
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Self-citationIntroduction to Linear Regression Analysis
Porter, D. R., Montgomery, D. C., & Peck, E. A. (1993) · Technometrics · doi:10.2307/1269673 · Cited by 974
Reliability of the Fugl-Meyer Assessment of Sensorimotor Recovery Following Cerebrovascular Accident
Duncan, P. W., Propst, M., & Nelson, S. G. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1606 · Cited by 962
THE RESTORATION OF MOTOR FUNCTION FOLLOWING HEMIPLEGIA IN MAN
TWITCHELL, T. E. (1951) · Brain · doi:10.1093/brain/74.4.443 · Cited by 940
Prange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917
Movement Smoothness Changes during Stroke Recovery
Rohrer, B., Fasoli, S., Krebs, H. I., Hughes, R., Volpe, B., Frontera, W. R., Stein, J., & Hogan, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-18-08297.2002 · Cited by 767
Self-citation
Cited by
On the analysis of movement smoothness
Balasubramanian, S., Melendez-Calderon, A., Roby-Brami, A., & Burdet, E. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0090-9 · Cited by 575
Murphy, M. A., Willén, C., & Sunnerhagen, K. S. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968310370748 · Cited by 360
Assessment of movement quality in robot- assisted upper limb rehabilitation after stroke: a review
Nordin, N., Xie, S., & Wünsche, B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-137 · Cited by 271
Robotic Measurement of Arm Movements After Stroke Establishes Biomarkers of Motor Recovery
Krebs, H. I., Krams, M., Agrafiotis, D. K., DiBernardo, A., Chavez, J. C., Littman, G. S., Yang, E., Byttebier, G., Dipietro, L., Rykman, A., et al. (2014) · Stroke · doi:10.1161/strokeaha.113.002296 · Cited by 154
Self-citation
Metadata
- Authors
- Bosecker, C., Dipietro, L., Volpe, B., & Igo Krebs, H.
- Venue
- Neurorehabilitation and Neural Repair
- Publisher
- SAGE Publications
- Published
- 2009-08-14
- Volume
- 24
- Issue
- 1
- Pages
- 62-69
- ISSN
- 0888-4390 (ISSN-L)
- 1545-9683
- 1552-6844
- OpenAlex
- W1992343783
- Cited by
- 300
- References
- 38
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinematic Robot-Based Evaluation Scales and Clinical Counterparts to Measure Upper Limb Motor Performance in Patients With Chronic Stroke. https://app.cochat.ai/papers/10.1177/1545968309343214
- The paper
- Bosecker, C., Dipietro, L., Volpe, B., & Igo Krebs, H. (2010). Kinematic Robot-Based Evaluation Scales and Clinical Counterparts to Measure Upper Limb Motor Performance in Patients With Chronic Stroke. Neurorehabilitation and Neural Repair. https://doi.org/10.1177/1545968309343214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.