Does Functional Electrical Stimulation for Foot Drop Strengthen Corticospinal Connections?
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background. Long-term use of a foot-drop stimulator applying functional electrical stimulation (FES) to the common peroneal nerve improves walking performance even when the stimulator is off. This “therapeutic” effect might result from neuroplastic changes. Objective. To determine the effect of long-term use of a foot-drop stimulator on residual corticospinal connections in people with central nervous system disorders. Methods. Ten people with nonprogressive disorders (eg, stroke) and 26 with progressive disorders (eg, multiple sclerosis) used a foot-drop stimulator for 3 to 12 months while walking in the community. Walking performance and electrophysiological variables were measured before and after FES use. From the surface electromyogram of the tibialis anterior muscle, we measured the following: (1) motor-evoked potential (MEP) from transcranial magnetic stimulation over the motor cortex, (2) maximum voluntary contraction (MVC), and (3) maximum motor wave (M max) from stimulating the common peroneal nerve. Results. After using FES, MEP and MVC increased significantly by comparable amounts, 50% and 48%, respectively, in the nonprogressive group and 27% and 17% in the progressive group; the changes were positively correlated ( R 2 = .35; P < .001). Walking speed increased with the stimulator off (therapeutic effect) by 24% ( P = .008) and 7% ( P = .014) in the nonprogressive and progressive groups, respectively. The changes in M max were small and not correlated with changes in MEP. Conclusions. The large increases in MVC and MEP suggest that regular use of a foot-drop stimulator strengthens activation of motor cortical areas and their residual descending connections, which may explain the therapeutic effect on walking speed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 1,033
Input-output properties and gain changes in the human corticospinal pathway
Devanne, H., Lavoie, B. A., & Capaday, C. (1997) · Experimental Brain Research · doi:10.1007/pl00005641 · Cited by 819
Techniques and mechanisms of action of transcranial stimulation of the human motor cortex
Rothwell, J. C. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02242-5 · Cited by 646 · cited 1×
“During the past 30 years, TMS has become increasingly popular for measuring corticospinal connections.(6,7) TMS produces little discomfort and stimulates cortical circuits that then activate pyramidal neurons synaptically in the motor cortex.”
BackgroundMechanisms of use-dependent plasticity in the human motor cortex
Bütefisch, C. M., Davis, B. C., Wise, S. P., Sawaki, L., Kopylev, L., Classen, J., & Cohen, L. G. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.7.3661 · Cited by 613 · cited 3×
“Voluntary activation or repetitive electrical stimulation of nerves in a limb may produce large, transient changes (minutes to hours) in MEPs.(8-10,28,29) Our participants used FES during walking on a daily basis, which may have produced accumulating effects that developed over a few days or months.”
BackgroundIncreases in Corticospinal Tract Function by Treadmill Training After Incomplete Spinal Cord Injury
Thomas, S. L., & Gorassini, M. A. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00532.2005 · Cited by 249
LTP forms 1, 2 and 3: different mechanisms for the ‘long’ in long-term potentiation
Raymond, C. R. (2007) · Trends in Neurosciences · doi:10.1016/j.tins.2007.01.007 · Cited by 240 · cited 2×
“Long-term potentiation of neural pathways, which might be an underlying mechanism, has been described with different time courses, depending on whether protein synthesis and/or gene expression are activated.(26) Some anecdotal observations in our patients further support the hypothesis.”
BackgroundDisynaptic reciprocal inhibition of ankle extensors in spastic patients
Crone, C., Nielsen, J., Petersen, N., Ballegaard, M., & Hultborn, H. (1994) · Brain · doi:10.1093/brain/117.5.1161 · Cited by 224 · cited 1×
“Reduced disynaptic inhibition of the soleus muscle has also been reported in various CNS conditions.(24) Because of lack of inhibition, the antagonist calf muscles may not be turned off with TA activity during the swing phase, which may also contribute to foot drop.”
BackgroundStein, R. B., Everaert, D. G., Thompson, A. K., Chong, S. L., Whittaker, M., Robertson, J., & Kuether, G. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309347681 · Cited by 208 · cited 5×
“The amount that participants walked on a daily basis was not controlled but was measured by the WalkAide device.(12) The participants of the TMS study were already community ambulators, walking 1850 steps/day on average before WalkAide use, and they increased their walking to about 2100 steps/day during the study.”
BackgroundMethodSelf-citationInvestigating human motor control by transcranial magnetic stimulation
Nielsen, J. B., Pyndt, H. S., & Petersen, N. T. (2003) · Experimental Brain Research · doi:10.1007/s00221-003-1537-y · Cited by 207 · cited 1×
“During the past 30 years, TMS has become increasingly popular for measuring corticospinal connections.(6,7) TMS produces little discomfort and stimulates cortical circuits that then activate pyramidal neurons synaptically in the motor cortex.”
BackgroundKhaslavskaia, S., Ladouceur, M., & Sinkjær, T. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1094-9 · Cited by 168 · cited 2×
“We did not measure MEPs at rest (without background contraction), because some participants had no resting MEP at all, and in many participants, we could not measure a 50-mV response that is sometimes used as a criterion to determine the TMS threshold for a resting MEP in the TA muscle.(8,15) The MEPs were averaged pe…”
BackgroundMethodKhaslavskaia, S., & Sinkjær, T. (2005) · Experimental Brain Research · doi:10.1007/s00221-004-2153-1 · Cited by 162 · cited 3×
“Voluntary activation or repetitive electrical stimulation of nerves in a limb may produce large, transient changes (minutes to hours) in MEPs.(8-10,28,29) Our participants used FES during walking on a daily basis, which may have produced accumulating effects that developed over a few days or months.”
BackgroundRosenkranz, K., & Rothwell, J. C. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04605.x · Cited by 150 · cited 1×
“Which combinations of sensory-motor signals are most effective to promote plasticity is not clear, and different signals may have different roles.(27) Voluntary activation or repetitive electrical stimulation of nerves in a limb may produce large, transient changes (minutes to hours) in MEPs.”
BackgroundTranscranial magnetic stimulation during resistance training of the tibialis anterior muscle
Griffin, L., & CAFARELLI, E. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.05.001 · Cited by 149 · cited 3×
“This increase was associated with an increased MEP with no change in the M-wave.31 Thus, our data and other recent studies support the hypothesis proposed in the Introduction section that repetitive daily stimulation makes the transient changes in MEPs longer lasting and more stable.”
ResultInfluentialKnash, M. E., Kido, A., Gorassini, M. A., Chan, K. M., & Stein, R. B. (2003) · Experimental Brain Research · doi:10.1007/s00221-003-1628-9 · Cited by 136 · cited 2×
“2 mV) than the values of 1 to 3 mV typically obtained for controls.(9) Figure 3 shows a map of the MEPs that were elicited by stimulation over different points of the cortex for the same participant as in the upper parts of Figure 1.”
BackgroundSelf-citationMulticenter evaluation of electrical stimulation systems for walking
Wieler, M., Stein, R. B., Ladouceur, M., Whittaker, M., Smith, A. W., Naaman, S. C., Barbeau, H., Bugaresti, J., & Aimone, E. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90188-0 · Cited by 135
Self-citationA Multicenter Trial of a Footdrop Stimulator Controlled by a Tilt Sensor
Stein, R. B., Chong, S., Everaert, D. G., Rolf, R., Thompson, A. K., Whittaker, M., Robertson, J., Fung, J., Preuss, R. A., Momose, K., et al. (2006) · Neurorehabilitation and neural repair · doi:10.1177/1545968306289292 · Cited by 135
Self-citationExperience of Clinical Use of the Odstock DroppedFoot Stimulator
Burridge, J., Taylor, P., Hagan, S., & Swain, I. (1997) · Artificial Organs · doi:10.1111/j.1525-1594.1997.tb04662.x · Cited by 110
Changes in Motor Unit Estimates with Aging
Galea, V. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199605000-00010 · Cited by 108
Thompson, A. K., & Stein, R. B. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1972-4 · Cited by 106 · cited 2×
“In contrast, 30 minutes of walking on a treadmill did not increase corticospinal excitability.(10) Thomas and Gorassini(11) reported an increased response to TMS (46%) after 3 to 5 months of intensive treadmill training in patients with incomplete spinal cord injury (SCI).”
BackgroundSelf-citationDavey, N. J., Smith, H. C., Savic, G. I., Maskill, D., ELLAWAY, P. H., & Frankel, H. L. (1999) · Experimental Brain Research · doi:10.1007/s002210050806 · Cited by 102
Induction of persistent changes in the organisation of the human motor cortex
McKay, D. R., Ridding, M. C., Thompson, P. D., & Miles, T. S. (2002) · Experimental Brain Research · doi:10.1007/s00221-001-0995-3 · Cited by 102 · cited 1×
“Our participants used FES during walking on a daily basis, which may have produced accumulating effects that developed over a few days or months.(30) In resistance training of the TA muscle in able-bodied persons, MVC increased faster in the first couple of weeks than could be accounted for by protein synthesis in the…”
MethodProbable Corticospinal Tract Control of Spinal Cord Plasticity in the Rat
Chen, X. Y., & Wolpaw, J. R. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00391.2001 · Cited by 98
van Hedel, H. J. A., Murer, C., Dietz, V., & Curt, A. E. P. (2007) · Journal of Neurology · doi:10.1007/s00415-006-0493-4 · Cited by 82
Barbeau, H. (2000) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655000750045712 · Cited by 74
Thickbroom, G. W., Sacco, P., Faulkner, D. L., Kermode, A. G., & Mastaglia, F. L. (2008) · Journal of Neurology · doi:10.1007/s00415-008-0818-6 · Cited by 74
Motor Unit Populations in Healthy and Diseased Muscles
McComas, A. J., Galea, V., & de Bruin, H. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.868 · Cited by 70
Thompson, A. K., Estabrooks, K. L., Chong, S., & Stein, R. B. (2008) · Neurorehabilitation and neural repair · doi:10.1177/1545968308321067 · Cited by 55 · cited 3×
“Other muscles, such as the ankle plantar flexors that are not being stimulated by the foot-drop stimulator, did not change.(18) Therefore, strengthening the voluntary control of only the ankle dorsiflexor muscles would be expected to have a small effect on the overall walking speed.”
BackgroundResultSelf-citationRoy, F. D., Norton, J. A., & Gorassini, M. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00197.2007 · Cited by 54 · cited 1×
“We did not measure MEPs at rest (without background contraction), because some participants had no resting MEP at all, and in many participants, we could not measure a 50-mV response that is sometimes used as a criterion to determine the TMS threshold for a resting MEP in the TA muscle.(8,15) The MEPs were averaged pe…”
Method
Cited by
Restoration of sensorimotor functions after spinal cord injury
Dietz, V., & Fouad, K. (2014) · Brain · doi:10.1093/brain/awt262 · Cited by 288
Mrachacz-Kersting, N., Jiang, N., Stevenson, A. J. T., Niazi, I. K., Kostic, V., Pavlovic, A., Radovanovic, S., Djuric-Jovicic, M., Agosta, F., Dremstrup, K., et al. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00918.2015 · Cited by 275
Neuromuscular electrical stimulation: implications of the electrically evoked sensory volley
Bergquist, A. J., Clair, J. M., Lagerquist, O., Mang, C. S., Okuma, Y., & Collins, D. F. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2087-9 · Cited by 271
Neural interfaces for the brain and spinal cord—restoring motor function
Jackson, A., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 253
Mrachacz‐Kersting, N., Kristensen, S. R., Niazi, I. K., & Farina, D. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.222851 · Cited by 250
“Repetitive electrical stimulation leads to increases in excitability of the cortical projections to the target muscle that are accompanied by significant functional improvements (e.g. walking speed in stroke patients) (Everaert et al. 2010).”
Background
Metadata
- Authors
- Everaert, D. G., Thompson, A. K., Chong, S. L., & Stein, R. B.
- Venue
- Neurorehabilitation and Neural Repair
- Publisher
- SAGE Publications
- Published
- 2009-10-27
- Volume
- 24
- Issue
- 2
- Pages
- 168-177
- ISSN
- 0888-4390 (ISSN-L)
- 1545-9683
- 1552-6844
- OpenAlex
- W2109554249
- Cited by
- 227
- References
- 29
- FWCI
- 10.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.