Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Does the Evaluation of Gait Quality During Daily Life Provide Insight Into Fall Risk? A Novel Approach Using 3-Day Accelerometer Recordings

Weiss, Aner, Brozgol, Marina, Dorfman, Moran, Herman, Talia, Shema, Shirley, Giladi, Nir, Hausdorff, Jeffrey M.·2013·Neurorehabilitation and Neural Repair

Abstract

Background. Many approaches are used to evaluate fall risk. While their properties and performance vary, most reflect performance at a specific moment or are based on subjective self-report. Objective. To quantify fall risk in the home setting using an accelerometer. Methods. Seventy-one community-living older adults were studied. In the laboratory, fall risk was assessed using performance-based tests of mobility (eg, Timed Up and Go) and usual walking abilities were quantified. Subsequently, subjects wore a triaxial accelerometer on their lower back for 3 consecutive days. Acceleration-derived measures were extracted from segments that reflected ambulation. These included total activity duration, number of steps taken, and the amplitude and width at the dominant frequency in the power spectral density, that is, parameters reflecting step-to-step variability. Afterwards, self-report of falls was collected for 6 months to explore the predictive value. Results. Based on a history of 2 or more falls, subjects were classified as fallers or nonfallers. The number of steps during the 3 days was similar ( P = .42) in the fallers (7842.1 ± 6135.6) and nonfallers (9055.3 ± 6444.7). Compared with the nonfallers, step-to-step consistency was lower in the fallers in the vertical axis (amplitude fallers, 0.58 ± 0.22 psd; nonfallers, 0.71 ± 0.18 psd; P = .008); in the mediolateral axis, step-to-step consistency was higher in the fallers ( P = .014). The 3-day measures improved the identification of past and future falls status ( P < .005), compared to performance-based tests. Conclusions. Accelerometer-derived measures based on 3-day recordings are useful for evaluating fall risk as older adults perform daily living activities in their everyday home environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1545968313491004

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Weiss, A., Brozgol, M., Dorfman, M., Herman, T., Shema, S., Giladi, N., & Hausdorff, J. M.
Venue
Neurorehabilitation and Neural Repair
Published
2013-06-17
Volume
27
Issue
8
Pages
742-752
ISSN
  • 0888-4390 (ISSN-L)
  • 1545-9683
  • 1552-6844
OpenAlex
W2156809737
Cited by
304
References
4
FWCI
52.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.