Abstract

Background . Recent neuroimaging studies on poststroke aphasia revealed maladaptive cortical changes in both hemispheres, yet their functional contribution in language recovery remains elusive. The aim of this study was to evaluate the long-term efficacy of dual-hemisphere repetitive transcranial magnetic stimulation (rTMS) on poststroke aphasia. Methods . Thirty patients with subacute poststroke nonfluent aphasia were randomly allocated to receive real or sham rTMS. Each patient received 1000 rTMS pulses (1 Hz at 110% of resting motor threshold [rMT] over the right unaffected Broca’s area and 1000 pulses (20 Hz at 80% rMT) over the left affected Broca’s area for 10 consecutive days followed by speech/language training. The language section of the Hemispheric Stroke Scale (HSS), the Stroke Aphasic Depression Questionnaire–Hospital Version (SADQ-H), and the National Institutes of Health Stroke Scale (NIHSS) were measured before, immediately after the 10 sessions, and 1 and 2 months after the last session. Results . At baseline, there were no significant differences between groups in demographic and clinical rating scales. However, there was a significantly greater improvement in the HSS language score as well as in the SADQ-H after real rTMS compared with sham rTMS, which remained significant 2 months after the end of the treatment sessions. Conclusion . This is the first clinical study of dual-hemisphere rTMS in poststroke aphasia. Combining dual-hemisphere rTMS with language training might be a feasible treatment for nonfluent aphasia; further multicenter studies are needed to confirm this result.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1545968314521009

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 113

Metadata

Authors
Khedr, E. M., Abo El-Fetoh, N., Ali, A. M., El-Hammady, D. H., Khalifa, H., Atta, H., & Karim, A. A.
Venue
Neurorehabilitation and Neural Repair
Published
2014-02-06
Volume
28
Issue
8
Pages
740-750
ISSN
  • 0888-4390 (ISSN-L)
  • 1545-9683
  • 1552-6844
OpenAlex
W2028041654
Cited by
113
References
4
FWCI
5.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-Hemisphere Repetitive Transcranial Magnetic Stimulation for Rehabilitation of Poststroke Aphasia: A Randomized, Double-Blind Clinical Trial. https://app.cochat.ai/papers/10.1177/1545968314521009
The paper
Khedr, E. M., Abo El-Fetoh, N., Ali, A. M., El-Hammady, D. H., Khalifa, H., Atta, H., & Karim, A. A. (2014). Dual-Hemisphere Repetitive Transcranial Magnetic Stimulation for Rehabilitation of Poststroke Aphasia: A Randomized, Double-Blind Clinical Trial. Neurorehabilitation and Neural Repair. https://doi.org/10.1177/1545968314521009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.