Brain-computer interface (BCI) technology has the prospects of helping stroke survivors by enabling the interaction with their environment through brain signals rather than through muscles, and restoring motor function by inducing activity-dependent brain plasticity. This paper presents a clinical study on the extent of detectable brain signals from a large population of stroke patients in using EEG-based motor imagery BCI. EEG data were collected from 54 stroke patients whereby finger tapping and motor imagery of the stroke-affected hand were performed by 8 and 46 patients, respectively. EEG data from 11 patients who gave further consent to perform motor imagery were also collected for second calibration and third independent test sessions conducted on separate days. Off-line accuracies of classifying the two classes of EEG from finger tapping or motor imagery of the stroke-affected hand versus the EEG from background rest were then assessed and compared to 16 healthy subjects. The mean off-line accuracy of detecting motor imagery by the 46 patients ( μ=0.74) was significantly lower than finger tapping by 8 patients ( μ=0.87, p=0.008), but not significantly lower than motor imagery by healthy subjects ( μ=0.78, p=0.23). Six stroke patients performed motor imagery at chance level, and no correlation was found between the accuracies of detecting motor imagery and their motor impairment in terms of Fugl-Meyer Assessment ( p=0.29). The off-line accuracies of the 11 patients in the second session ( μ=0.76) were not significantly different from the first session ( μ=0.72, p=0.16), or from the on-line accuracies of the third independent test session ( μ=0.82, p=0.14). Hence this study showed that the majority of stroke patients could use EEG-based motor imagery BCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Introduction to statistical pattern recognition (2nd ed.)
Fukunaga, K. (1990) · Academic Press Professional, Inc. eBooks · Cited by 3,797
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 2×
“The second stage performs CSP spatial filtering.(33) Each pair of band-pass and spatial filter computes the CSP features that are specific to the band-pass frequency range by linearly transforming the EEG using”
MethodBrain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
Filter Bank Common Spatial Pattern (FBCSP) in Brain-Computer Interface
Ang, K. K., Chin, Z. Y., Zhang, H., & Guan, C. (2008) · 2008 IEEE International Joint Conference on Neural Networks (IEEE World Congress on Computational Intelligence) · doi:10.1109/ijcnn.2008.4634130 · Cited by 1,514
Self-citation
Research works printed but not linked: 2
- 10.1016/j.compbiomed.2009.02.004 · DOI
- Ang KK, 2011, Pattern Recogn
Cited by
Ang, K. K., Chua, K. S. G., Phua, K. S., Wang, C., Chin, Z. Y., Kuah, C. W. K., Low, W., & Guan, C. (2015) · Clinical EEG and Neuroscience · doi:10.1177/1550059414522229 · Cited by 539
Self-citationNoninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016) · Scientific Reports · doi:10.1038/srep38565 · Cited by 484
BCI for stroke rehabilitation: motor and beyond
Mane, R., Chouhan, T., & Guan, C. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba162 · Cited by 466
Self-citationAng, K. K., Guan, C., Phua, K. S., Wang, C., Zhou, L., Tang, K. Y., Ephraim Joseph, G. J., Kuah, C. W. K., & Chua, K. S. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00030 · Cited by 361
Self-citationEEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289
Self-citationVárkuti, B., Guan, C., Pan, Y., Phua, K. S., Ang, K. K., Kuah, C. W. K., Chua, K., Ang, B. T., Birbaumer, N., & Sitaram, R. (2013) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968312445910 · Cited by 267
Self-citationEEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Roberts, Dyson, & Gan, 2011), and Parzon window (Ang et al., 2011).”
Deep Representation-Based Domain Adaptation for Nonstationary EEG Classification
Zhao, H., Zheng, Q., Ma, K., Li, H., & Zheng, Y. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3010780 · Cited by 253
A Deep Transfer Convolutional Neural Network Framework for EEG Signal Classification
Xu, G., Shen, X., Chen, S., Zong, Y., Zhang, C., Yue, H., Liu, M., Chen, F., & Che, W. (2019) · IEEE Access · doi:10.1109/access.2019.2930958 · Cited by 232
“During the past few years, many studies have focused on the feature extraction and classification phases since they can greatly impact the MI BCI system performance [14-16].”
BackgroundBrain-Computer Interface in Stroke Rehabilitation
Ang, K. K., & Guan, C. (2013) · Journal of Computing Science and Engineering · doi:10.5626/jcse.2013.7.2.139 · Cited by 212
“[40] presented a study on the extent of detectable brain signals from a large population of 54 stroke patients in using EEG-based BCI to perform MI of upper limb.”
BackgroundSelf-citationFoong, R., Ang, K. K., Quek, C., Guan, C., Phua, K. S., Kuah, C. W. K., Deshmukh, V. A., Yam, L. H. L., Rajeswaran, D. K., Tang, N., et al. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2921198 · Cited by 196
“distribution with a 95% confidence estimate [7].”
Self-citationXu, R., Jiang, N., Mrachacz-Kersting, N., Lin, C., Asin Prieto, G., Moreno, J. C., Pons, J. L., Dremstrup, K., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2313867 · Cited by 185
“In these studies, SMR-based BCI was used to provide visual feedback or to trigger external devices, such as ES [3]–[6] or orthoses [7], [8], aiming at the rehabilitation of motor functions [9], [11], [34], [35].”
MethodBhagat, N. A., Venkatakrishnan, A., Abibullaev, B., Artz, E. J., Yozbatiran, N., Blank, A. A., French, J., Karmonik, C., Grossman, R. G., O'Malley, M. K., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00122 · Cited by 174
“SMR, [MEG] 73 (18), [median] Daly et al., 2008 Daly et al., 2008 3 SMR 82-98 Ang et al., 2011 Ang et al., 2011 11 – Current study [online] combines high dimensional spatio-temporal ERP features and subsequently classifies into target vs. non-target using either regularized-LDA or multiple Logistic…”
BackgroundMethodLi, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“MIT-Manus planar shoulder and elbow robotic arm [77].”
Micoulaud-Franchi, J.-A., McGonigal, A., Lopez, R., Daudet, C., Kotwas, I., & Bartolomei, F. (2015) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2015.10.077 · Cited by 111
“[3] Ang KK, Guan C, Chua KS, Ang BT, Kuah CW, Wang C, et al.”
Ma, Z.-Z., Wu, J.-J., Cao, Z., Hua, X.-Y., Zheng, M.-X., Xing, X.-X., Ma, J., & Xu, J.-G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01387-w · Cited by 97
Metadata
- Authors
- Ang, K. K., Guan, C., Chua, K. S. G., Ang, B. T., Kuah, C. W. K., Wang, C., Phua, K. S., Chin, Z. Y., & Zhang, H.
- Venue
- Clinical EEG and Neuroscience
- Publisher
- SAGE Publications
- Published
- 2011-10
- Volume
- 42
- Issue
- 4
- Pages
- 253-258
- ISSN
- 1550-0594 (ISSN-L)
- 2169-5202
- OpenAlex
- W2158573165
- Cited by
- 299
- References
- 35
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.