The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index; 8 of the 9 sources its claims cite were checked for support.
Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Open accessAbstract
Brain-computer interface (BCI) technologies aim to provide a bridge between the human brain and external devices. Prior research using non-invasive BCI to control virtual objects, such as computer cursors and virtual helicopters, and real-world objects, such as wheelchairs and quadcopters, has demonstrated the promise of BCI technologies. However, controlling a robotic arm to complete reach-and-grasp tasks efficiently using non-invasive BCI has yet to be shown. In this study, we found that a group of 13 human subjects could willingly modulate brain activity to control a robotic arm with high accuracy for performing tasks requiring multiple degrees of freedom by combination of two sequential low dimensional controls. Subjects were able to effectively control reaching of the robotic arm through modulation of their brain rhythms within the span of only a few training sessions and maintained the ability to control the robotic arm over multiple months. Our results demonstrate the viability of human operation of prosthetic limbs using non-invasive BCI technology.
Overview
CoChat Summary
TL;DR
Thirteen healthy subjects used a noninvasive EEG motor-imagery BCI to control a 7-DOF robotic arm for reach-and-grasp tasks in 3D by combining sequential low-dimensional controls. Performance improved with training, exceeded chance, and was maintained over multiple months, supporting the viability of noninvasive BCI for prosthetic-limb control.
Key findings
- Across 8–15 sessions, 1D left-right cursor control averaged 78.4 ± 7.0% PVC in session 1, rose to 90.2 ± 3.1% in session 2, and exceeded 95% in later sessions; 2D cursor control averaged 77.0 ± 9.3% initially and increased above 85% after seven sessions.
- Four-target grasp averaged 80.3 ± 17.0% PVC across two sessions; five-target grasp averaged 77.9 ± 14.7% across three sessions. For six subjects, four-target PVC was 90.1 ± 7.7% without the virtual cursor vs. 89.9 ± 8.9% with it (n.s., p > 0.05), while five-target PVC was 79.0 ± 8.3% without vs. 85.1 ± 8.0% with it (p = 0.031).
- In random-target grasp, 10 subjects grasped 7.4 ± 1.3 blocks per run (max 10), took 6.4 ± 0.7 s per step and 30.5 ± 4.1 s per block; success rate exceeded 62.2% across the accessible workspace except bottom-center areas, where median was 53.1% and minimum 47.2%.
- In shelf-target grasp, 8 subjects moved 4.6 ± 0.9 blocks per run (max 6), took 6.0 ± 0.5 s per step and 63.8 ± 5.1 s per block; fast-shelf-target reduced time to 40.6 ± 5.8 s per block, about 36% faster, with similar blocks per run (5.1 ± 0.6 vs. 5.1 ± 0.5). Empirical chance levels were 25.3% for four-target and 22.5% for five-target virtual tasks.
Methods
- 18 healthy subjects were recruited; 5 dropped early, leaving 13 analyzed (7 women; mean age 27.3 y; range 18–54) who completed 8–15 sessions over an average of 81 ± 34 days.
- EEG was recorded with a 64-channel Neuroscan cap; 62 channels acquired, with C3/C4 and surrounding motor-cortex channels used online. Signals were spatially filtered with a small Laplacian, modeled with a 16th-order autoregressive model over a 400-ms window, and upper mu (10–14 Hz) power was linearly mapped to cursor/robotic-arm velocity. A JACO 7-DOF robotic arm served as actuator.
- Five progressive stages were used: virtual cursor only, four-target grasp, five-target grasp, random-target grasp, and shelf-target grasp. Reach-and-grasp used a two-step sequence with a 2-s hover requirement; statistical comparisons used two-sided Wilcoxon signed-rank tests at α = 0.05.
Limitations
- Stated: the study used healthy subjects, not patients; the approach used sequential low-dimensional control rather than fluid 3D continuous control; fluid 3D control would require at least three independent control signals and had not yet been shown; decoding was minimally customized per subject; a high-speed robotic arm was not available; the hover period increased task complexity; performance varied day by day; and some subjects dropped before later stages.
- Stated: in the presence vs. absence of the virtual cursor, only five-target PVC showed a significant difference; possible reasons included occasional robotic-arm lag, physical speed limits, and visual distortion without the cursor.
- Evident from the text: the sample was small and healthy, the workspace was constrained, grasping was partly shared/automatic after hover, and the system was tested in laboratory sessions rather than in daily-life or home use.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
8 Valid · 2 Not valid · 1 Not checked · 96 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Bilateral ERD was apparent when the subject performed the bilateral hand motor imagination for the up target (Fig. 3 up target), and bilateral ERS was apparent when the subject relaxed for the down target (Fig. 3 down target).”
§ Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks > Results > Event related de/synchrozination maps of 2D virtual cursor control
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Additionally, the bilateral ERS was also not as strong as the virtual cursor control counterpart.”
§ Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks > Results > Event related de/synchrozination maps of robotic control
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Across all sessions from all participants, performance was significantly higher than expected by chance alone (see the green line for 2D cursor movement in Fig. 2).”
§ Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks > Results > Empirical chance level of virtual cursor task
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“but there was an occasional delay in the movement of the robotic arm if the brain rhythm generated a relatively large acceleration.”
§ Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks > Discussion > Performance in the presence and absence of virtual cursor
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The average empirical chance level for the four and five target experiments were 25.3% (347 abort trials among 750 trials) and 22.5% (162 abort trials among 625 trials) respectively, which are close to the theoretical values of 25% and 20% for typical four/five target experimental paradigms without hovering time.”
§ Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks > Results > Empirical chance level of virtual cursor task
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
58 more claims
Create a free account to see all 107 claims and every source verdict.
- Probably not a substantial claim. 22
- It may state two separate claims as one. 30
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“The results presented here demonstrate that CP control provides a unique opportunity for the complex control of a virtual cursor and robotic device (14, 39), without requiring discretized, prolonged task sequences (46) that can make even simple task completion long and frustrating.”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [46]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“Evidence that co-adaptive MI BCIs might also be able to promote and increase the ability of the users to voluntary modulate their brain signals (subject learning) is, in fact, scarce, most often indirect and rather inconclusive.”
From The Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users (2018) · cites this paper as [36]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Indeed, mutual learning has been claimed mostly on the grounds of adequate and improved BCI classification accuracy [25,27,30–35] or application performances [36,37].”
From The Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users (2018) · cites this paper as [36]
Experimental — accuracy not yet measuredIn the citing paper
“Secondly, other training studies claim learnability in BCIs only on the grounds of improved online classification accuracy [9,27,30,31,33,35,51] or application performances [36,37].”
From The Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users (2018) · cites this paper as [36]
Citations
Cites
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Spatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Noninvasive neuroimaging enhances continuous neural tracking for robotic device control
Edelman, B. J., Meng, J., Suma, D., Zurn, C., Nagarajan, E., Baxter, B. S., Cline, C. C., & He, B. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6844 · Cited by 380
“The results presented here demonstrate that CP control provides a unique opportunity for the complex control of a virtual cursor and robotic device (14, 39), without requiring discretized, prolonged task sequences (46) that can make even simple task completion long and frustrating.”
Self-citationSubject-Independent Brain–Computer Interfaces Based on Deep Convolutional Neural Networks
Kwon, O.-Y., Lee, M.-H., Guan, C., & Lee, S.-W. (2020) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2019.2946869 · Cited by 347
“Over the course of numerous BCI studies [16]–[21], growing attention has been dedicated to the analysis of electroencephalography (EEG) signals, especially by movement imagination, called motor imagery (MI) [1], [2], [8], [12], [14], [16], [22].”
BackgroundHS-CNN: a CNN with hybrid convolution scale for EEG motor imagery classification
Dai, G., Zhou, J., Huang, J., & Wang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab405f · Cited by 336
Metadata
- Authors
- Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- He, Bin
- Venue
- Scientific Reports
- Published
- 2016-12-14
- Volume
- 6
- Issue
- 1
- Pages
- 38565-38565
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5155290
- OpenAlex
- W2561907433
- Semantic Scholar
- a350cd9acaac8aa6a07018363b63e333ef3e8f39
- Cited by
- 484
- References
- 40
- Citations by year
- 2026: 23 · 2025: 48 · 2024: 52 · 2023: 55 · 2022: 45 · 2021: 60 · 2020: 59 · 2019: 57 · 2018: 60 · 2017: 25
- FWCI
- 30.03
- Type
- journal article
- Language
- en
- Update notices
- correction (2020-04-15)
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (1264782, 1069104)
- National Institutes of Health (NSF DGE-1069104, DGE-1069104)
- National Institute of Neurological Disorders and Stroke (R01NS096761)
- National Institute of Biomedical Imaging and Bioengineering (R01EB021027)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems (1264782, CBET-1264782)
- National Center for Complementary and Integrative Health (R01AT009263)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, robotic arm control, reach and grasp, prosthetic control, motor imagery, neural oscillations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks. https://app.cochat.ai/papers/10.1038/srep38565
- The paper
- Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016). Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks. Scientific Reports. https://doi.org/10.1038/srep38565
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.