A review on phase change material application in building
Open accessThe DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Abstract
In the past several decades, many literatures have emerged on the topic of phase change material and latent heat storage techniques used in building. Accordingly, it is essential to review previous work to know about phase change material application in building better. This article presents a review on phase change material application situations in building, and several aspects are discussed: phase change material major applications in building, phase change material application areas, phase change material application types, phase change material thermal–physical properties, and phase change material application effects. The results of this research show that phase change material application areas are mainly concentrated into four parts of north latitude from 25° to 60° and south latitude from 25° to 40°. No matter in which region, the use of paraffin is the broadest (the maximum use frequency is up to 87.5%). For organic phase change material, the melting temperature and the heat of fusion vary from 19°C to 29°C and from 120 kJ/kg to 280 kJ/kg, respectively. The best phase change material application effect found is a reduction of 4.2°C for air temperature in room. This study has important and directive significance for the practical application of phase change material in building.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review on thermal energy storage with phase change materials and applications
Sharma, A., Tyagi, V. V., Chen, C. R., & Buddhi, D. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.10.005 · Cited by 5,936 · cited 6×
“Shapiro et al.32 investigated methods for impregnating gypsum wallboard and other architectural materials with PCM, and several workers investigated methods for impregnating gypsum and other PCMs.33–35”
BackgroundInfluentialZalba, B., Marı́n, J. M., Cabeza, L. F., & Mehling, H. (2003) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00192-8 · Cited by 4,738
A review on phase change energy storage: materials and applications
Farid, M. M., Khudhair, A. M., Razack, S. A. K., & Al-Hallaj, S. (2004) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.09.015 · Cited by 3,097
Materials used as PCM in thermal energy storage in buildings: A review
Cabeza, L. F., Castell, A., Barreneche, C., de Gracia, A., & Fernández, A. I. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.11.018 · Cited by 1,889
Low temperature latent heat thermal energy storage: Heat storage materials
Abhat, A. (1983) · Solar Energy · doi:10.1016/0038-092x(83)90186-x · Cited by 1,711 · cited 3×
“And then additional measurements will be taken to make up for relatively poor properties of picked materials, for example, introducing a nucleating agent to avoid super-cooling and using fin designs or graphite to increase thermal conductivity of PCMs.28,51,52 When selecting PCMs integrated into building, melting temp…”
BackgroundPCM thermal storage in buildings: A state of art
Tyagi, V. V., & Buddhi, D. (2007) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.10.002 · Cited by 1,090 · cited 2×
“Then a schematic of standard solar air-based heating system is shown in Figure 8.(25)”
BackgroundMethodA review on phase change material (PCM) for sustainable passive cooling in building envelopes
Akeiber, H., Nejat, P., Majid, M. Z. A., Wahid, M. A., Jomehzadeh, F., Zeynali Famileh, I., Calautit, J. K., Hughes, B. R., & Zaki, S. A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.036 · Cited by 1,075
Soares, N., Costa, J. J., Gaspar, A. R., & Santos, P. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.12.042 · Cited by 1,061
A review on phase change materials integrated in building walls
Kuznik, F., David, D., Johannes, K., & Roux, J.-J. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.08.019 · Cited by 1,057
Use of microencapsulated PCM in concrete walls for energy savings
Cabeza, L. F., Castellón, C., Nogués, M., Medrano, M., Leppers, R., & Zubillaga, O. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.030 · Cited by 889
Cited by
Drissi, S., Ling, T.-C., Mo, K. H., & Eddhahak, A. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.072 · Cited by 237
Arumugam, P., Ramalingam, V., & Vellaichamy, P. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111840 · Cited by 174
Tyagi, V. V., Chopra, K., Kalidasan, B., Chauhan, A., Stritih, U., Anand, S., Pandey, A. K., Sarı, A., & Kothari, R. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101318 · Cited by 169
Wang, H., Lu, W., Wu, Z., & Zhang, G. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.05.124 · Cited by 167
Phase change materials for pavement applications: A review
Anupam, B. R., Sahoo, U. C., & Rath, P. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.118553 · Cited by 166
Ji, K., Wi, S., Jun, H., Suh, J.-I., Song, H., & Yoon, J. (2025) · International Journal of Concrete Structures and Materials · doi:10.1186/s40069-025-00861-6 · Cited by 3
“The utilization of PCM has been mainly investigated in concrete buildings as a passive (wall, floor, and ceiling) or active (separate heat and cold storage devices) system to increase their thermal energy storage and efficiency (Cui et al., 2017; Feng et al., 2016; Han et al., 2017).”
Metadata
- Authors
- Cui, Y., Xie, J., Liu, J., Wang, J., & Chen, S.
- Venue
- Advances in Mechanical Engineering
- Publisher
- SAGE Publications
- Published
- 2017-06
- Volume
- 9
- Issue
- 6
- Pages
- 168781401770082
- ISSN
- 1687-8132 (ISSN-L)
- 1687-8140
- OpenAlex
- W2625348916
- Cited by
- 241
- References
- 135
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.