Cited by 11Muscle activation and electromyography studiesProsthetics and Rehabilitation RoboticsHuman Motion and Animation

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Prediction of knee trajectory based on surface electromyogram with independent component analysis combined with support vector regression

Open access
Zhu, Meng, Guan, XiaoRong, Li, Zhong, Gao, YunLong, Zou, KaiFan, Gao, XinAn, Wang, Zheng, Li, HuiBin, Cai, KeShu·2022·International Journal of Advanced Robotic Systems

Abstract

In recent years, surface electromyogram signals have been increasingly used to operate wearable devices. These devices can aid to help workers or soldiers to lower the load in the task to boost efficiency. However, achieving effective signal prediction has always been a challenge. It is critical to use an appropriate signal preprocessing method and prediction algorithm when developing a controller that can accurately predict and control human movements in real time. For this purpose, this article investigates the effect of various surface electromyogram preprocessing methods and algorithms on prediction results. Walking data (surface electromyogram angle) were collected from 10 adults (5 males and 5 females). To investigate the effect of preprocessing methods on the experimental results, the raw surface electromyogram signals were grouped and subjected to different preprocessing (bandpass/principal component analysis/independent component analysis, respectively). The processed data were then imported into the random forest and support vector regression algorithm for training and prediction. Multiple scenarios were combined to compare the results. The independent component analysis-processed data had the best performance in terms of convergence time and prediction accuracy in the support vector regression algorithm. The prediction accuracy of knee motion with this scheme was 94.54% ± 2.98. Notably, the forecast time was halved in comparison to the other combinations. The independent component analysis algorithm’s “blind source separation” feature effectively separates the original surface electromyogram signal and reduces signal noise, hence increasing prediction efficiency. The main contribution of this work is that the method (independent component analysis + support vector regression) has the potency of best prediction of surface electromyogram signal for knee movement. This work is the first step toward myoelectric control of assisted exoskeleton robots through discrete decoding.

Overview

Integrity signals

Registry

Crossref · 10.1177/17298806221119668

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. Tsuji T, 2010, Bullet Japanese Soc Prosth Ortho, 26, 91
  2. Sato M, 2011, SICE Annual Conference 2011

Cited by

Sorted by citations

Metadata

Authors
Zhu, M., Guan, X., Li, Z., Gao, Y., Zou, K., Gao, X., Wang, Z., Li, H., & Cai, K.
Affiliations
  • Nanjing University of Science and Technology (CN)
  • School of Mechanical Engineering, Nanjing University of Science and Technology, Xiaolingwei, Nanjing City, Jiangsu Province, China
  • Jiangsu Province Hospital (CN)
Corresponding author
Guan, XiaoRong
Venue
International Journal of Advanced Robotic Systems
Published
2022-07-01
Volume
19
Issue
4
ISSN
  • 1729-8806 (ISSN-L)
  • 1729-8814
OpenAlex
W4293544165
Cited by
11
References
32
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 4
FWCI
0.65
Type
journal article
Language
en
Open access
Locations
  • International Journal of Advanced Robotic Systems (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
NATIONAL DEFENSE BASIC SCIENTIFIC RESEARCH PROGRAM OF CHINA (JCKY2019209B003)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Computer Science › Computer Graphics and Computer-Aided Design › Human Motion and Animation
Keywords
surface electromyogram, independent component analysis, support vector regression, bandpass filtering, principal component analysis, myoelectric control, wearable exoskeleton, blind source separation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review