The DOI matches its Crossref record.
Comparison of Thermal Conductivity Measurements of Building Insulation Materials under Various Operating Temperatures
Abstract
In harsh climates, utilizing thermal insulation in the building envelope can substantially reduce the building thermal load and consequently its energy consumption. The performance of the thermal insulation material is mainly determined by its thermal conductivity (k), which is dependent on the material’s density, porosity, moisture content, and mean temperature difference. In practice, the k-value is normally evaluated at 24 C (i.e., k 24) according to relevant ASTM standards. However, when placed in the building envelope, thermal insulation materials can be exposed to significant ambient temperature and humidity variations depending on the prevailing climatic conditions. The objective of this study is to assess and compare the effect of operating temperatures on the k-value of various insulation materials commonly used in the building envelope. The k-values for seven categories of insulation materials (i.e., fiberglass, wood wool, mineral wool, rock wool, polyethylene, polyurethane, and polystyrene) are measured at different mean temperatures using an automated heat flow meter. Some preliminary measurements are reported for the purpose of assessing the impact of k-value variation on envelope-induced cooling loads (Budaiwi et al. 2002). In this study, comprehensive measurements, comparison, and analyses of results are presented and discussed. These underline the k-value degree of sensitivity ((Δk/ΔC)/k 24) of various insulation materials with rising operating temperature. This would allow designers to better evaluate the thermal performance of building envelopes leading to a more realistic thermal assessment and energy requirements of buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermal conductivity of concrete – A review
Asadi, I., Shafigh, P., Abu Hassan, Z. F. B., & Mahyuddin, N. B. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2018.07.002 · Cited by 803
de Brito, J., & Kurda, R. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.123558 · Cited by 436
Villasmil, W., Fischer, L. J., & Worlitschek, J. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.12.040 · Cited by 329
Malik, M., Bhattacharyya, S. K., & Barai, S. V. (2021) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.121398 · Cited by 259
Metadata
- Authors
- Abdou, A. A., & Budaiwi, I. M.
- Venue
- Journal of Building Physics
- Publisher
- SAGE Publications
- Published
- 2005-10
- Volume
- 29
- Issue
- 2
- Pages
- 171-184
- ISSN
- 1097-1963 (ISSN-L)
- 1744-2591
- 1744-2583
- OpenAlex
- W2125462304
- Cited by
- 164
- References
- 0
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Thermal Conductivity Measurements of Building Insulation Materials under Various Operating Temperatures. https://app.cochat.ai/papers/10.1177/1744259105056291
- The paper
- Abdou, A. A., & Budaiwi, I. M. (2005). Comparison of Thermal Conductivity Measurements of Building Insulation Materials under Various Operating Temperatures. Journal of Building Physics. https://doi.org/10.1177/1744259105056291
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.