Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Automated endoscopic detection and classification of colorectal polyps using convolutional neural networks

Open access
Ozawa, Tsuyoshi, Ishihara, Soichiro, Fujishiro, Mitsuhiro, Kumagai, Youichi, Shichijo, Satoki, Tada, Tomohiro · 2020 · Therapeutic Advances in Gastroenterology

Abstract

Background: Recently the American Society for Gastrointestinal Endoscopy addressed the ‘resect and discard’ strategy, determining that accurate in vivo differentiation of colorectal polyps (CP) is necessary. Previous studies have suggested a promising application of artificial intelligence (AI), using deep learning in object recognition. Therefore, we aimed to construct an AI system that can accurately detect and classify CP using stored still images during colonoscopy. Methods: We used a deep convolutional neural network (CNN) architecture called Single Shot MultiBox Detector. We trained the CNN using 16,418 images from 4752 CPs and 4013 images of normal colorectums, and subsequently validated the performance of the trained CNN in 7077 colonoscopy images, including 1172 CP images from 309 various types of CP. Diagnostic speed and yields for the detection and classification of CP were evaluated as a measure of performance of the trained CNN. Results: The processing time of the CNN was 20 ms per frame. The trained CNN detected 1246 CP with a sensitivity of 92% and a positive predictive value (PPV) of 86%. The sensitivity and PPV were 90% and 83%, respectively, for the white light images, and 97% and 98% for the narrow band images. Among the correctly detected polyps, 83% of the CP were accurately classified through images. Furthermore, 97% of adenomas were precisely identified under the white light imaging. Conclusions: Our CNN showed promise in being able to detect and classify CP through endoscopic images, highlighting its high potential for future application as an AI-based CP diagnosis support system for colonoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1756284820910659

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 158

Metadata

Authors
Ozawa, T., Ishihara, S., Fujishiro, M., Kumagai, Y., Shichijo, S., & Tada, T.
Venue
Therapeutic Advances in Gastroenterology
Published
2020-01
Volume
13
Pages
1756284820910659-1756284820910659
ISSN
  • 1756-283X (ISSN-L)
  • 1756-2848
OpenAlex
W3011484919
Cited by
158
References
9
FWCI
7.70
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated endoscopic detection and classification of colorectal polyps using convolutional neural networks. https://app.cochat.ai/papers/10.1177/1756284820910659
The paper
Ozawa, T., Ishihara, S., Fujishiro, M., Kumagai, Y., Shichijo, S., & Tada, T. (2020). Automated endoscopic detection and classification of colorectal polyps using convolutional neural networks. Therapeutic Advances in Gastroenterology. https://doi.org/10.1177/1756284820910659

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.