Cited by 95Diabetes Management and ResearchElectrochemical sensors and biosensorsPancreatic function and diabetes

Amperometric Glucose Sensors: Sources of Error and Potential Benefit of Redundancy

Open access
Castle, Jessica R., Ward, W. Kenneth·2010·Journal of Diabetes Science and Technology

Abstract

Amperometric glucose sensors have advanced the care of patients with diabetes and are being studied to control insulin delivery in the research setting. However, at times, currently available sensors demonstrate suboptimal accuracy, which can result from calibration error, sensor drift, or lag. Inaccuracy can be particularly problematic in a closed-loop glycemic control system. In such a system, the use of two sensors allows selection of the more accurate sensor as the input to the controller. In our studies in subjects with type 1 diabetes, the accuracy of the better of two sensors significantly exceeded the accuracy of a single, randomly selected sensor. If an array with three or more sensors were available, it would likely allow even better accuracy with the use of voting.

Integrity signals

Registry

Crossref · 10.1177/193229681000400127

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The erratic outputs with posture changes were attributed in part to blood occlusion from pressures applied to tissue adjacent to the sensor.

    “Such behavior was attributed in part to blood occlusion due to pressures applied to tissue adjacent to the sensor.86–87”

The citation lists haven’t been fetched yet

References 19 · Cited by 95

Authors
Castle, J. R., & Ward, W. K.
Affiliations
Oregon Health Services University, Portland, Oregon
Corresponding author
Ward, W. Kenneth
Venue
Journal of Diabetes Science and Technology
Published
2010-01
Volume
4
Issue
1
Pages
221-225
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1964143445
Cited by
95
References
19
Citations by year
2026: 4 · 2025: 2 · 2024: 4 · 2023: 8 · 2022: 7 · 2021: 6 · 2020: 1 · 2019: 3 · 2018: 6 · 2017: 10 · 2016: 6 · 2015: 10 · 2014: 5 · 2013: 8 · 2012: 6
FWCI
5.57
Type
journal article
Language
en
Open access
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute of Diabetes and Digestive and Kidney Diseases (T32DK007674)
  • National Center for Research Resources (M01RR000334)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
amperometric glucose sensor, sensor error, sensor redundancy, sensor drift, calibration error, type 1 diabetes, insulin delivery, sensor arrays
MeSH terms
Blood Glucose, Calibration, Diabetes Mellitus, Type 1, Equipment Design, Humans, Hypoglycemic Agents, Insulin Infusion Systems, Research Design, Blood Glucose Self-Monitoring, Biosensing Techniques, Infusion Pumps, Implantable, Monitoring, Ambulatory, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review