Correlation between Plantar Foot Temperature and Diabetic Neuropathy: A Case Study by Using an Infrared Thermal Imaging Technique
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Diabetic neuropathy consists of multiple clinical manifestations of which loss of sensation is most prominent. High temperatures under the foot coupled with reduced or complete loss of sensation can predispose the patient to foot ulceration. The aim of this study was to look at the correlation between plantar foot temperature and diabetic neuropathy using a noninvasive infrared thermal imaging technique. Methods: Infrared thermal imaging, a remote and noncontact experimental tool, was used to study the plantar foot temperatures of 112 subjects with type 2 diabetes selected from a tertiary diabetes centre in South India. Results: Patients with diabetic neuropathy (defined as vibration perception threshold (VPT) values on biothesiometry greater than 20 V) had a higher foot temperature (32–35 °C) compared to patients without neuropathy (27–30 °C). Diabetic subjects with neuropathy also had higher mean foot temperature (MFT) ( p = .001) compared to non-neuropathic subjects. MFT also showed a positive correlation with right great toe ( r = 0.301, p = .001) and left great toe VPT values ( r = 0.292, p = .002). However, there was no correlation between glycated hemoglobin and MFT. Conclusion: Infrared thermal imaging may be used as an additional tool for evaluation of high risk diabetic feet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin Temperature Monitoring Reduces the Risk for Diabetic Foot Ulceration in High-risk Patients
Armstrong, D. G., Holtz-Neiderer, K., Wendel, C., Mohler, M. J., Kimbriel, H. R., & Lavery, L. A. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2007.06.028 · Cited by 437
Preventing Diabetic Foot Ulcer Recurrence in High-Risk Patients
Lavery, L. A., Higgins, K. R., Lanctot, D. R., Constantinides, G. P., Zamorano, R. G., Athanasiou, K. A., Armstrong, D. G., & Agrawal, C. M. (2007) · Diabetes Care · doi:10.2337/dc06-1600 · Cited by 434
A perspective on medical infrared imaging
Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y. (2005) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331333158 · Cited by 283
Pradeepa, R., Rema, M., Vignesh, J., Deepa, M., Deepa, R., & Mohan, V. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02397.x · Cited by 199
Self-citationBharara, M., Cobb, J. E., & Claremont, D. J. (2006) · The International Journal of Lower Extremity Wounds · doi:10.1177/1534734606293481 · Cited by 184
Premalatha, G., Shanthirani, S., Deepa, R., Markovitz, J., & Mohan, V (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1295 · Cited by 176
Self-citationVisualization of body thermoregulation by infrared imaging
Bouzida, N., Bendada, A., & Maldague, X. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.11.008 · Cited by 175
Thermal Imaging Today and Its Relevance to Diabetes
Ring, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400414 · Cited by 167 · cited 1×
“J Diabetes Sci Technol 2010;4(6):1386-1392 ORIGINAL ARTICLES”
J�rneskog, G., Brismar, K., & Fagrell, B. (1995) · Diabetologia · doi:10.1007/bf00410286 · Cited by 141
Arora, S., Smakowski, P., Frykberg, R. G., Simeone, L. R., Freeman, R., LoGerfo, F. W., & Veves, A. (1998) · Diabetes Care · doi:10.2337/diacare.21.8.1339 · Cited by 136
Cited by
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Self-citationInfrared thermography for condition monitoring – A review
Bagavathiappan, S., Lahiri, B. B., Saravanan, T., Philip, J., & Jayakumar, T. (2013) · Infrared Physics & Technology · doi:10.1016/j.infrared.2013.03.006 · Cited by 979
Self-citationInfrared thermography (IRT) applications for building diagnostics: A review
Kylili, A., Fokaides, P. A., Christou, P., & Kalogirou, S. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.08.005 · Cited by 526
An overview of corrosion defect characterization using active infrared thermography
Doshvarpassand, S., Wu, C., & Wang, X. (2019) · Infrared Physics & Technology · doi:10.1016/j.infrared.2018.12.006 · Cited by 241
Infrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177
Metadata
- Authors
- Bagavathiappan, S., Philip, J., Jayakumar, T., Raj, B., Rao, P. N. S., Varalakshmi, M., & Mohan, V.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-11
- Volume
- 4
- Issue
- 6
- Pages
- 1386-1392
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2136908561
- Cited by
- 204
- References
- 19
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.