Basic Performance of an Enzymatic Method for Glycated Albumin and Reference Range Determination
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Glycated albumin (GA) is a medium-term glycemic control marker of diabetes and may be more sensitive to changes in plasma glucose than hemoglobin A1c. We studied where and how many fructosyl groups bind to albumin, and which glycation sites are measured by the enzymatic method for GA. We also studied the basic performance of the enzymatic method for GA. Methods: Glycated albumin was measured using an enzymatic method (Lucica®GA-L, Asahi Kasei Pharma) on a biochemical autoanalyzer. Molecular weights of purified GA and nonglycated albumin were measured by a mass spectrometry system. Two hundred one healthy volunteers with normal results of oral glucose tolerance testing were recruited to determine the reference range in Americans. Results: The present method measured only glycated amino acids from albumin in serum protein. We estimate that the number of glycated amino acids measured by this method was approximately two per molecule of albumin. The general performance (sensitivity, specificity, reproducibility, linearity, interference) of the method was good. The reference range of GA% in Americans with normal glucose tolerance was determined to be 11.9–15.8% (mean ± 2 standard deviations). Significant differences were not observed between the sexes; however, race differences were observed (higher levels in blacks relative to whites). Conclusions: The method was specific for measuring glycated amino acids in albumin and had good basic performance characteristics. The reference range in Americans was 11.9–15.8%. This method may be a useful indicator for diabetes control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin
Bry, L., Chen, P. C., & Sacks, D. B. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.153 · Cited by 523 · cited 1×
“J Diabetes Sci Technol 2011;5(6):1455-1462 ORIGINAL ARTICLE”
Tahara, Y., & Shima, K. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.440 · Cited by 380 · cited 2×
“Because the enzymatic method is ideal for measuring analytes quantitatively, we studied the (1) specificity, (2) target molecules of GA measurement, and (3) basic performance, including reference range in an American population, of this method.”
MethodClinical impact of glycated albumin as another glycemic control marker
Koga, M., & Kasayama, S. (2010) · Endocrine Journal · doi:10.1507/endocrj.k10e-138 · Cited by 290
Racial differences in glycemic markers: a cross-sectional analysis of community-based data
Selvin, E., Steffes, M. W., Ballantyne, C. M., Hoogeveen, R. C., Coresh, J., & Brancati, F. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-5-201103010-00004 · Cited by 196
Cited by
Selvin, E., Rawlings, A. M., Grams, M., Klein, R., Sharrett, A. R., Steffes, M., & Coresh, J. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(13)70199-2 · Cited by 262
Welsh, K. J., Kirkman, M. S., & Sacks, D. B. (2016) · Diabetes Care · doi:10.2337/dc15-2727 · Cited by 207
“A number of glycated albumin assays are commercially available, but these lack standardization and values vary widely among methods (54).”
BackgroundYazdanpanah, S., Rabiee, M., Tahriri, M., Abdolrahim, M., Rajab, A., Jazayeri, H. E., & Tayebi, L. (2017) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2017.1299684 · Cited by 194
“Normal range of GA by assay [46].”
Glycated albumin: a potential biomarker in diabetes
Freitas, P. A. C., Ehlert, L. R., & Camargo, J. L. (2017) · Archives of Endocrinology and Metabolism · doi:10.1590/2359-3997000000272 · Cited by 184
“frozen samples at -80oC maintained the GA levels stable for 4 years (31).”
BackgroundMethodResultInfluentialWright, L. A.-C., & Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0029 · Cited by 178
“, bilirubin, uric acid),(31) while GA reflects the proportion of GA to total serum albumin, expressed by a ratio (%), as a result, the changes in serum protein concentration have less of an impact on GA than in FA.(38,39) An important limitation to the use of glycated proteins is the lack of established clinical cut p…”
Background
Metadata
- Authors
- Kohzuma, T., Yamamoto, T., Uematsu, Y., Shihabi, Z. K., & Freedman, B. I.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-11
- Volume
- 5
- Issue
- 6
- Pages
- 1455-1462
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2138685848
- Cited by
- 122
- References
- 4
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.