Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by Bolus Calculators
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
People with diabetes on insulin pumps often use a bolus calculator (BC) to obtain insulin dose recommendations. After the first bolus of the day, residual insulin activity, called bolus insulin on board (BOB), must be correctly accounted for to reduce the size of subsequent boluses and minimize the insulin stacking that would otherwise occur. Critical to achieving this calculation is having an appropriate duration of insulin action (DIA) setting in the BC. Unfortunately, the widespread use of inappropriately short DIAs may be causing unrecognized “stacking” of insulin that leads to unexplained hypoglycemic events. Currently, there is no widely accepted definition or value of the DIA for use in a BC. Various shortcomings regarding the selection of an appropriate DIA setting have led to considerable confusion among clinicians and insulin pump users about this important concept. Traditional pharmacological studies used to determine the pharmacodynamic (PD) properties of rapid-acting insulins create a misleading impression that insulin action times (IATs) in daily life vary from 3 to 5 hours and cause IATs to appear more variable than they actually are. These IAT time ranges are not appropriate for use as the DIA time value required to obtain an accurate bolus recommendation from a BC. We highlight the problems that arise when an inappropriately short DIA leads to excessive bolus recommendations, provide a research protocol to accurately measure DIA, and suggest appropriate DIA time recommendations for use in current clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Self-citationHirsch, I. B., Bode, B. W., Garg, S., Lane, W. S., Sussman, A., Hu, P., Santiago, O. M., Kolaczynski, J. W., & for the Insulin Aspart CSII/MDI Comparison Study Group (2005) · Diabetes Care · doi:10.2337/diacare.28.3.533 · Cited by 197
Cross-reactivity of three recombinant insulin analogs with five commercial insulin immunoassays
Owen, W. E., & Roberts, W. L. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026625 · Cited by 123
Walsh, J., Roberts, R., & Bailey, T. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400516 · Cited by 103
Self-citation
Cited by
Schmidt, S., & Nørgaard, K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532906 · Cited by 170
Braune, K., Lal, R. A., Petruželková, L., Scheiner, G., Winterdijk, P., Schmidt, S., Raimond, L., Hood, K. K., Riddell, M. C., Skinner, T. C., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00267-9 · Cited by 130
Reddy, M., Pesl, P., Xenou, M., Toumazou, C., Johnston, D., Georgiou, P., Herrero, P., & Oliver, N. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0413 · Cited by 70
A novel pen-based Bluetooth-enabled insulin delivery system with insulin dose tracking and advice
Bailey, T. S., & Stone, J. Y. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1313831 · Cited by 60
“When multiple insulin doses are given within a short period of time, the prolonged action time of rapid or short-acting insulin doses can create an unintended excess in insulin activity, commonly referred to as ‘insulin stacking’ [12,13].”
Background
Metadata
- Authors
- Walsh, J., Roberts, R., & Heinemann, L.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-01
- Volume
- 8
- Issue
- 1
- Pages
- 170-178
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2129634754
- Cited by
- 71
- References
- 5
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by Bolus Calculators. https://app.cochat.ai/papers/10.1177/1932296813514319
- The paper
- Walsh, J., Roberts, R., & Heinemann, L. (2014). Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by Bolus Calculators. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296813514319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.