Evaluating Quality of Glycemic Control: Graphical Displays of Hypo- and Hyperglycemia, Time in Target Range, and Mean Glucose
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: There is need for readily understandable graphical displays of glucose data to facilitate interpretation by clinicians and researchers. Methods: (1) Display of the percentage of glucose values above a specified threshold for hyperglycemia (%High) versus percentage of glucose values below a specified threshold for hypoglycemia (%Low). If all glucose values fell within the target range, then all data points would fall at the origin. (2) After an intervention, one can plot the change in percentage of glucose values above a specified threshold for hyperglycemia versus the change in percentage of glucose values below a specified threshold defining hypoglycemia: The quadrants of this graph correspond to (a) increased risk of both hyper- and hypoglycemia, (b) decreased hyperglycemia but increased risk of hypoglycemia, (c) decreases in both hypo- and hyperglycemia, and (d) decreased hypoglycemia but increased hyperglycemia. (3) A 2-dimensional triangular graph can be used for simultaneous display of %High, %Low, and percentage in target range. (4) Display of risk of hyper- versus risk of hypoglycemia based on both frequency and severity of departures from the target range can be used. (5) Graphs (1) and (4) can also be presented using percentile scores relative to a reference population. (6) It is also useful to analyze %Hypoglycemia or risk of hypoglycemia versus mean glucose. Results: These methods are illustrated with examples from representative cases and shown to be feasible, practical, and informative. Conclusions: These new types of graphical displays can facilitate rapid analysis of risks of hypo- and hypoglycemia simultaneously and responses to therapeutic interventions for individuals or in clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Variability; Does It Matter?
Siegelaar, S. E., Holleman, F., Hoekstra, J. B. L., & DeVries, J. H. (2010) · Endocrine Reviews · doi:10.1210/er.2009-0021 · Cited by 409
Ambulatory Glucose Profile: Representation of Verified Self-Monitored Blood Glucose Data
Mazze, R. S., Lucido, D., Langer, O., Hartmann, K., & Rodbard, D. (1987) · Diabetes Care · doi:10.2337/diacare.10.1.111 · Cited by 144
Self-citationReduced daily risk of glycemic variability: comparison of exenatide with insulin glargine
McCall, A. L., Cox, D. J., Brodows, R., Crean, J., Johns, D., & Kovatchev, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0107 · Cited by 46 · cited 1×
“The present methods should be compared with other graphical methods and numerical indices that have been proposed to evaluate glycemic control.(1-10) HbA1c had been regarded as the gold standard but there is a growing recognition that it is inadequate as a measure of quality of glycemic control.”
Method
Cited by
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Self-citationThe relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479
Self-citationContinuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Self-citationKlonoff, D. C., Wang, J., Rodbard, D., Kohn, M. A., Li, C., Liepmann, D., Kerr, D., Ahn, D., Peters, A. L., Umpierrez, G. E., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221085273 · Cited by 295
Self-citationBergenstal, R. M. (2015) · Diabetes Care · doi:10.2337/dc15-0099 · Cited by 140
Metadata
- Authors
- Rodbard, D.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-10-14
- Volume
- 9
- Issue
- 1
- Pages
- 56-62
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2113764001
- Cited by
- 41
- References
- 3
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.