CoChat

V-Go Insulin Delivery System Versus Multiple Daily Insulin Injections for Patients With Uncontrolled Type 2 Diabetes Mellitus

Open access
Winter, Abigail, Lintner, Michaela, Knezevich, Emily · 2015 · Journal of Diabetes Science and Technology
Cited by 30

The DOI matches its Crossref record.

Abstract

Type 2 diabetes mellitus affects over 29.1 million Americans, diagnosed and undiagnosed. Achieving and maintaining glycemic control for these patients is of extreme importance when working to prevent complications and improve quality of life for patients. The V-Go is a newly developed insulin delivery system. The push of a button inserts a needle into the patient once daily and remains attached for 24 hours. The V-Go is designed to release a set basal rate throughout the day, while allowing patients to provide up to 36 units of on-demand bolus insulin with the manual click of 2 buttons. It is a spring-loaded device filled daily with rapid-acting insulin that runs without the use of batteries or computer software. The main objective of this prospective active comparator study was to observe the A1C lowering effects of multiple daily insulin injections (MDII) versus the use of the V-Go insulin delivery system for patients with uncontrolled type 2 diabetes mellitus over a 3-month period. In addition, the effect on insulin requirement for these patients was assessed with secondary comparisons of weight, blood pressure, prevalence of hypoglycemic events, and quality of life before and after 3 months of intensified insulin therapy with regular monitoring by a clinical pharmacist at an internal medicine clinic. The average A1C lowering experienced by the 3 patients in the V-Go group was 1.5%, while the average A1C change in the 3 patients in the MDII group was an increase of 0.2%. All patients in the V-Go group experienced a decrease in insulin total daily dose (TDD), with an average decrease of 26.3 units. All patients in the MDII group experienced an increase in insulin TDD with an average of 15 units daily to achieve therapeutic goals individualized for each patient. All patients who underwent intensification of insulin therapy experienced an increase in subjective quality of life (QOL) as determined using the Diabetes-39 (D-39) questionnaire, though QOL results lacked statistical significance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296815580361

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 30

Metadata

Authors
Winter, A., Lintner, M., & Knezevich, E.
Venue
Journal of Diabetes Science and Technology
Published
2015-04-21
Volume
9
Issue
5
Pages
1111-1116
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2106371616
Cited by
30
References
0
FWCI
1.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: V-Go Insulin Delivery System Versus Multiple Daily Insulin Injections for Patients With Uncontrolled Type 2 Diabetes Mellitus. https://app.cochat.ai/papers/10.1177/1932296815580361
The paper
Winter, A., Lintner, M., & Knezevich, E. (2015). V-Go Insulin Delivery System Versus Multiple Daily Insulin Injections for Patients With Uncontrolled Type 2 Diabetes Mellitus. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296815580361

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.