Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM)
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objective: To understand differences between individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D) in utilization of continuous glucose monitoring (CGM) data to adjust insulin therapy, either continuous subcutaneous insulin infusion (CSII) or multiple daily insulin injections (MDI). Methods: We surveyed 300 individuals who regularly used real-time CGM, using 70 questions to obtain information about general CGM use and response to glucose rate of change (ROC) arrows. Results: The survey was completed by 222 T1D and 78 T2D respondents treated with intensive insulin therapy. T1D respondents included CSII (n = 166) and MDI (n = 56) users. T2D respondents were more balanced: 34 (44%) versus 44 (56%), respectively. A larger percentage of T1D then T2D respondents reported a constant use of CGM (85% vs 61%, P < .001). T1D and T2D respondents reported similar substantial increases in correction dosages in response to rapidly increasing glucose (>3 mg/dL/min; 2 arrows up): +140% versus +136%, P = .4534. However, T1D respondents reported making smaller correction dosage reductions than T2D respondents in response to rapidly decreasing glucose (−42% vs −80%, P < .001). Differences between T1D and T2D respondents were also observed in mealtime dosage adjustments in response to rapidly increasing glucose compared to when glucose is stable (flat arrow) at 110 mg/dl: +81% versus +108%, respectively ( P = .003). Although these adjustments are statistically different, both are large. Conclusions: CGM users often rely on ROC information when determining insulin doses and tend to be more aggressive in their insulin adjustments despite differences in type of diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159 · cited 1×
“Our survey showed that most respondents persistently used their CGM devices at frequencies associated with significant glycemic improvements in large clinical trials.(3,6,13-17) After 1 year of CGM use, most respondents reported reductions in frequency and severity of hypoglycemia, improvements in HbA1c levels, increa…”
BackgroundTumminia, A., Crimi, S., Sciacca, L., Buscema, M., Frittitta, L., Squatrito, S., Vigneri, R., & Tomaselli, L. (2015) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2557 · Cited by 100
Blevins, T. C., Bode, B. W., Garg, S. K., Grunberger, G., Hirsch, I. B., Jovanovič, L., Nardacci, E., Orzeck, E. A., Roberts, V. L., & Tamborlane, W. V. (2010) · Endocrine Practice · doi:10.4158/ep.16.5.730 · Cited by 98 · cited 1×
“Numerous studies have demonstrated that utilization of realtime continuous glucose monitoring (CGM) improves glycemic control in individuals with type 1 diabetes (T1D),(1-7) and is becoming accepted as part of the standard of care in the treatment of patients within this population.(8,9) The benefits of real-time CGM…”
BackgroundGarg, S. K., Voelmle, M. K., Beatson, C. R., Miller, H. A., Crew, L. B., Freson, B. J., & Hazenfield, R. M. (2011) · Diabetes Care · doi:10.2337/dc10-1852 · Cited by 85
Cited by
Ruedy, K. J., Parkin, C. G., Riddlesworth, T. D., & Graham, C. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817704445 · Cited by 225
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
“is rapidly falling or rising but differs in format between devices) (44,45) [3e].”
BackgroundWearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Reference Guide for Integrating Continuous Glucose Monitoring Into Clinical Practice
Kruger, D. F., Edelman, S. V., Hinnen, D. A., & Parkin, C. G. (2019) · The Diabetes Educator · doi:10.1177/0145721718818066 · Cited by 55
Self-citation
Metadata
- Authors
- Pettus, J., & Edelman, S. V.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-07-09
- Volume
- 10
- Issue
- 5
- Pages
- 1087-1093
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2336716591
- Cited by
- 23
- References
- 9
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM). https://app.cochat.ai/papers/10.1177/1932296816639069
- The paper
- Pettus, J., & Edelman, S. V. (2016). Differences in Use of Glucose Rate of Change (ROC) Arrows to Adjust Insulin Therapy Among Individuals With Type 1 and Type 2 Diabetes Who Use Continuous Glucose Monitoring (CGM). Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296816639069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.