The Clinical Case for the Integration of a Ketone Sensor as Part of a Closed Loop Insulin Pump System

Lee, Melissa H., Paldus, Barbora, Krishnamurthy, Balasubramanium, McAuley, Sybil A., Shah, Rajiv, Jenkins, Alicia J., O’Neal, David N.·2019·Journal of Diabetes Science and Technology

Abstract

Closed loop (CL) systems deliver insulin with a rapid onset and offset in action. Although favorable overall, the absence of a long-acting insulin increases the risk of diabetic ketoacidosis (DKA) which can occur with insulin delivery failure, acute illness, low carbohydrate diets, sodium glucose-linked transporter inhibitors, and high intensity exercise. A CL system relying entirely on interstitial glucose measurements may not provide an alert for DKA and many people with type 1 diabetes (T1D) do not carry a blood ketone meter and test-strips. Ketone sensing is theoretically feasible. A multianalyte platform incorporating a ketone sensor could provide an additional CL input without an increase in burden for the person with T1D, warning of impending DKA to allow remedial action to be taken. We outline the clinical case for inclusion of continuous ketone sensing as part of future CL systems.

Integrity signals

Registry

Crossref · 10.1177/1932296818822986

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Authors
Lee, M. H., Paldus, B., Krishnamurthy, B., McAuley, S. A., Shah, R., Jenkins, A. J., & O’Neal, D. N.
Affiliations
  • Department of Medicine, University of Melbourne, St. Vincent’s Hospital Melbourne, Fitzroy, Victoria, Australia
  • Percusense, Valencia, CA, USA
Venue
Journal of Diabetes Science and Technology
Published
2019-01-10
Volume
13
Issue
5
Pages
967-973
ISSN
1932-2968
Cited by
20
References
4
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review