Abstract
Background: Clinical trials often face challenges in efficient data collection and participant monitoring. To address these issues, we developed the IMPACT platform, comprising a real-time mobile application for data collection and a web-based dashboard for remote monitoring and management. Methods: This article presents the design, development, and usability assessment of the IMPACT platform customized for patients with post-bariatric surgery hypoglycemia (PBH). We focus on adapting key IMPACT components, including continuous glucose monitoring (CGM), symptom tracking, and meal logging, as crucial elements for user-friendly and efficient PBH monitoring. Results: The adapted IMPACT platform demonstrated effectiveness in data collection and remote participant monitoring. The mobile application allowed patients to easily track their data, while the clinician dashboard provided a comprehensive overview of enrolled patients, featuring filtering options and alert mechanisms for identifying data collection issues. The platform incorporated various visual representations, including time plots and category-based visualizations, which greatly facilitated data interpretation and analysis. The System Usability Scale questionnaire results indicated a high level of usability for the web dashboard, with an average score of 86.3 out of 100. The active involvement of clinicians throughout the development process ensured that the platform allowed for the collection and visualization of clinically meaningful data. Conclusions: By leveraging IMPACT’s existing features and infrastructure, the adapted version streamlined data collection, analysis, and trial customization for PBH research. The platform’s high usability underscores its alignment with the requirements for conducting research using continuous real-world data in PBH patients and other populations of interest.
Overview
CoChat Summary
TL;DR
The IMPACT platform was adapted via a user-centered, modular design process for real-world data collection in post-bariatric hypoglycemia (PBH) clinical research. In a usability assessment with nine clinical team members, the web dashboard achieved a mean System Usability Scale score of 86.3 out of 100.
Key findings
- The adapted IMPACT platform supported CGM, symptom, meal, activity, sleep, and step data collection, and was deployed in a prospective observational study involving 50 participants for 50 days of monitoring.
- The web dashboard’s mean SUS score was 86.3 (SD 10.8) among nine clinical team members (average age 29 ± five years; mean self-reported digital health experience 4.25), indicating good usability above the threshold of 70.
- Highest-scoring SUS items were Q2 (ease of use) and Q5 (integrated well); lowest-scoring were Q6 (confidence in using) and Q9 (need for technical support).
- Clinicians valued platform flexibility, but rare connectivity issues caused data gaps, increased participant interactions, and in some cases lower adherence to the trial protocol.
Methods
- The platform was adapted using a five-step nested design approach: assessing intended users and tasks, domain/data characterization, visual encoding and interaction design, prototype development, and first testing/validation.
- Requirements were gathered from literature review and interviews with the clinical research team; the prototype was developed in Flutter and tested for two weeks with clinicians acting as patients.
- Usability was assessed after the 50-day data collection period using the validated 10-item SUS questionnaire plus demographics and self-reported digital health experience, collected via an ad hoc website accessible only to the clinical team.
Limitations
- The paper states the platform was adapted specifically for the PBH study; meal data collection remained semi-quantitative, patients were not kept in the loop during development due to strict protocol requirements, dedicated patient interviews on mobile app features were not performed, and the usability assessment had a small sample size.
- The text makes evident that the usability assessment focused on the web dashboard and involved only the clinical team, not patients; the authors note plans to assess the mobile application with patients at study completion.
- The text also makes evident that the high SUS scores may be partly explained by the sample being young adults already experienced with digital health tools.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
6 Valid · 2 Not valid · 13 Not checked · 53 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“From the literature review of the previous step, 11 it has emerged that blood glucose sampling, symptom tracking, and meal recordings were the primary data that patients need to collect to observe and mitigate PBH events shortcoming.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Step 2: Domain and Data Characterization
What the sources say
- Partly supportedcites [11] matched to “Hypoglycemia After Upper Gastrointestinal Surgery: Clinical Approach to Assessment, Diagnosis, and Treatment” (2020) sourceExperimental — accuracy not yet measured
The Diagnosis section (page unavailable) recommends 7–10 days of continuous glucose monitoring alongside a diary of food, activity, and symptoms to identify glycemic patterns and hypoglycemia triggers. It does not call these the primary data patients need to collect generally, and it distinguishes CGM from blood sampling required to establish a diagnosis. (LLM, conf=0.83)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The platform incorporated various visual representations, including time plots and category-based visualizations, which greatly facilitated data interpretation and analysis.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Abstract
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the clinician dashboard provided a comprehensive overview of enrolled patients, featuring filtering options and alert mechanisms for identifying data collection issues.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The user experiences were, however, negatively influenced by rare events of limited technical robustness which resulted in frequent connectivity issues.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Usability Assessment
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The System Usability Scale questionnaire results indicated a high level of usability for the web dashboard, with an average score of 86.3 out of 100.”
- Also stated in: § Usability Assessment · hedged
“The mean SUS score for the assessed platform is 86.3, indicating good usability according to the threshold proposed in the work by Bangor et al 16 of a score above 70.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Abstract
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Usability Assessment · hedged
19 more claims
Create a free account to see all 74 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 27
- Probably not a substantial claim. 32
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Usability Assessment
“The mean SUS score for the assessed platform is 86.3, indicating good usability according to the threshold proposed in the work by Bangor et al 16 of a score above 70.”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > References
“16. Tao D, Or CKL, Li K. The influence of computer experi- ence and screen size on use performance and perceptions of a tablet-based chronic illness self-management system for older adults.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Step 4: Prototype Development
“The whole platform is developed in Flutter, a multiplatform framework which allows to ensure consistency in the visual design and functionalities among all components across different operating systems and eases the development by reducing the required iterations to ensure the same functionality in all platforms.14”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > References
“14. Brooke J. SUS: a quick and dirty usability scale. Usability Eval Ind. 1995;2:189.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > Step 3: Visual Encoding and Interaction Design
“The design of this section was inspired by the Ambulatory Glucose Profile, which represents the standardized way to report glucose management statistics in people with type 1 diabetes.13”
§ Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients > References
“13. Flutter-Build apps for any screen. https://flutter.dev/. Accessed July 11, 2023.”
Citations
Cites
SUS: A 'Quick and Dirty' Usability Scale
(1996) · Usability Evaluation In Industry · doi:10.1201/9781498710411-35 · Cited by 8,989
An Empirical Evaluation of the System Usability Scale
Bangor, A., Kortum, P. T., & Miller, J. T. (2008) · International Journal of Human–Computer Interaction · doi:10.1080/10447310802205776 · Cited by 5,181
Inan, O. T., Tenaerts, P., Prindiville, S. A., Reynolds, H. R., Dizon, D. S., Cooper-Arnold, K., Turakhia, M., Pletcher, M. J., Preston, K. L., Krumholz, H. M., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0302-y · Cited by 329
Hypoglycemia After Gastric Bypass Surgery: Current Concepts and Controversies
Salehi, M., Vella, A., McLaughlin, T., & Patti, M.-E. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-00528 · Cited by 239
Mitigating the Effects of Nonadherence in Clinical Trials
Shiovitz, T. M., Bain, E. E., McCann, D. J., Skolnick, P., Laughren, T., Hanina, A., & Burch, D. (2016) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.689 · Cited by 114
Bentley, C., Cressman, S., van der Hoek, K., Arts, K., Dancey, J., & Peacock, S. (2019) · Clinical Trials · doi:10.1177/1740774518820060 · Cited by 104
Glycemic Patterns Are Distinct in Post-Bariatric Hypoglycemia After Gastric Bypass (PBH-RYGB)
Lee, D., Dreyfuss, J. M., Sheehan, A., Puleio, A., Mulla, C. M., & Patti, M. E. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab323 · Cited by 45
Sheehan, A., & Patti, M. E. (2020) · Diabetes, Metabolic Syndrome and Obesity: Targets and Therapy · doi:10.2147/dmso.s233078 · Cited by 39 · cited 2×
“From the literature review of the previous step, 11 it has emerged that blood glucose sampling, symptom tracking, and meal recordings were the primary data that patients need to collect to observe and mitigate PBH events shortcoming.”
Designing a Personalized Health Dashboard: Interdisciplinary and Participatory Approach
Weijers, M., Bastiaenen, C., Feron, F., & Schröder, K. (2021) · JMIR Formative Research · doi:10.2196/24061 · Cited by 21
Usability factors of mobile health application for chronic diseases
Zahra, F., Hussain, A., & Mohd, H. (2016) · AIP Conference Proceedings · doi:10.1063/1.4960948 · Cited by 18
Cited by
Cossu, L., Prendin, F., Cappon, G., Herzig, D., Bally, L., & Facchinetti, A. (2025) · Clinical eHealth · doi:10.1016/j.ceh.2025.01.003 · Cited by 2
Self-citation
Metadata
- Authors
- Cossu, L., Cappon, G., Streicher, O., Herzig, D., Bally, L., & Facchinetti, A.
- Affiliations
- University of Padua (IT)
- University of Bern (CH)
- Corresponding author
- Facchinetti, Andrea
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2023-12-24
- Volume
- 19
- Issue
- 3
- Pages
- 673-682
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC12035038
- OpenAlex
- W4390166689
- Cited by
- 1
- References
- 14
- Citations by year
- 2025: 1
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Bern Open Repository and Information System (University of Bern) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- Dpt. of Information Engineering, University of Padova, Italy (SID-Networking Project 2021)
- Topics
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- continuous glucose monitoring, mobile health apps, remote patient monitoring, web dashboard, usability evaluation, System Usability Scale, symptom monitoring, real-world data, clinical trial data collection, bariatric patients
- MeSH terms
- User-Centered Design, Blood Glucose, Clinical Trials as Topic, Data Collection, Female, Humans, Hypoglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Bariatric Surgery, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients. https://app.cochat.ai/papers/10.1177/19322968231220061
- The paper
- Cossu, L., Cappon, G., Streicher, O., Herzig, D., Bally, L., & Facchinetti, A. (2025). Design and Usability Assessment of a User-Centered, Modular Platform for Real-World Data Acquisition in Clinical Trials Involving Post-Bariatric Surgery Patients. Journal of Diabetes Science and Technology. https://doi.org/10.1177/19322968231220061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.